Frost frequency converter high-performance
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
The detailed content
FST - 610 high-power series high-performance non-inductive vector frequency converter
(7.5 kw to 630 kw, 3 phase, 380 v)
Software features:
G/P and wide scope of application.
A variety of control mode: V/F control, non-inductive vector control and torque control.
High start torque: 180%, 0.5 Hz.
Multistage speed, simple PLC and PID control.
Programmable input/output terminals.
Instantaneous power lost, don't stop function.
Multiple frequency setting methods.
Speed tracking restart function.
Automatic output voltage adjustment function.
Frequency hopping control function.
Volatile inhibition function.
A variety of fault protection function.
Structure features:
Layout optimization of components, small volume, light weight, easy to transport, installation and maintenance.
Good heat dissipation design, low temperature, stable performance.
- Q: Laptop adapter
- The interface of the second adapter is the same as the first one And although the two numbers are not the same but the number of V on the line is the same as the interface
- Q: Laptop power adapter repair how much money
- Different notebook power adapter models are different, the price gap is large. ? Maintenance costs to see the specific model and damage level position. Generally do not recommend maintenance, it is recommended to replace the more appropriate. If you are not covered by the warranty period, you can repair free of charge. Hands-on ability to recommend self-repair, pay maintenance department recommended. After all, once again a greater chance of damage.
- Q: Notebook power adapter on how to look at power
- then the same formula can be used to calculate: power (unit: W) = voltage (unit: V) × current (unit: A). For example: the power adapter only identifies the output voltage is 20V, the output current is 4.5A, then we set a formula to know the output power is 20 × 4.5 = 90W.
- Q: Asus notebook power adapter how to open
- Hi respectful ASUS users The power adapter can not be disassembled, and if your machine's power adapter is faulty, you can go to the local service center for testing.
- Q: Can the notebook's power adapter be mixed?
- In general, the same brand of notebook power adapter, as long as the same wattage, the same interface, can be mixed with. But do not recommend different brands or different wattage power adapter mix. Because the output wattage is different, there may be damage to the notebook, such as voltage instability and so on.
- Q: My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
- Poor match, the program is unreasonable Current 1.5A, choose a single-phase 220v power supply, 370-500w inverter it
- Q: Will the laptop's power adapter is not the original good?
- Theoretically can be inserted into the use and will not have any obvious damage to the machine But it is best to buy the number of volt and your original consistent Original also has original benefits According to some "professional" sources claim that no original touchpad will have a slight jitter, I was not found
- Q: How to make the motor speed (control speed), can not use frequency
- In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.
- Q: Siemens g120 inverter torque limit what is the meaning
- Torque is a strain, the inverter can not actively control the output torque size, only according to the size of the load demand torque, the output of the corresponding torque.
- Q: Please recommend a high performance laptop power adapter?
- See what model you notebook ah, according to your power adapter voltage, rated current to match.
Send your message to us
Frost frequency converter high-performance
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords