Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Can the laptop power adapter be generic?
- Not necessarily, the laptop power adapter has two interfaces for input and output. 1. Input interface is connected to the power outlet, generally divided into two holes and three holes, as well as round mouth and flat mouth of the points; 2. Output interface is connected to the computer side, size, length, diameter, diameter, the pin may have differences, common are: diameter 2.5MM, ordinary mouth, mainstream interface; OD 1.7MM, small mouth; MM, big mouth with a needle, round mouth with a needle and so on. 3. Different voltage, different brands of laptop power adapter voltage is not the same 4. Current is different, different brands of notebook computer power adapter current is not the same In summary, the laptop power adapter between the different types, basically not common
- Q: What is the working principle of high voltage electrodes and frequency converters?
- High voltage inverter from high - low - high; low - high; high - high points. The following are the same as the " High-low-high-mode high-voltage inverter is the high-voltage power transformer with a step-down, with low-voltage inverter control, and then step up the transformer voltage to the voltage we use, the supply of high-voltage motor.
- Q: Laptop power adapter problem
- First, that is called the transformer, not called the charger, not with you bite the word, but you according to the charger to Taobao search, basically one hundred percent are not found.
- Q: My laptop can not use the power adapter, and can only use the battery, how is it ah,
- 1, laptop power adapter can not be used, first check the power outlet, plug, cable has no virtual state, if you can tell the normal equipment damage. Should be repaired. 2, the laptop battery must be charged through the power adapter or directly for the computer power, the power adapter is not missing, if you have experience can turn on the power adapter to see if the fuse is broken, try to update the fuse can be restored. If the integrated circuit is damaged, only updated.
- Q: Is the laptop power adapter long-haul?
- As long as the power, regardless of your access to the computer, the adapter is working. In fact, not much harm, anyway, five years of notebook life, this thing as long as not deliberately to damage, will be very durable, worse than the important parts of the computer slow. As long as the big brand, nothing Even if you broke, this thing can value a few money? In fact, the proposal or pull it, on the ground stumbling ... ...
- Q: There is no inverter comes with simple PLC programming function
- The PLC is programmed to handle digital and analog, the core of the entire control system. It can output the digital to the inverter, so that the inverter is reversing, you can output the analog to the inverter set speed, but also through the communication, direct control inverter
- Q: Is the motor having a variable frequency motor and a variable voltage motor?
- According to the way to start talking about a variable frequency motor and variable voltage motor
- Q: What is the frequency converter used to do, why some motor with the inverter?
- Frequency converter is widely used in the speed regulation of AC motor.Varameter speed control technology is an important development direction of modern power transmission technology, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious.
- Q: Can the inverter be used to control the speed of the DC motor?
- For the brush commutation DC motor, the speed of the output torque in a certain circumstances and the input voltage related. For this type of motor, use the inverter to control the output of the rectifier device that supplies power to the motor, which can control the speed. For the brushless DC motor, the controller is in accordance with a certain law to change the form of stator winding power supply to produce a rotating magnetic field to drive the rotor rotation. That is, the DC motor controller outside the part of the AC motor and the structure and the principle has not much difference (see below. For such motors, with the inverter to replace the controller, and control the same as the AC motor Control the speed.
- Q: Three motors, if coupled with the governor speed, is it necessary to add the inverter?
- ?Fifth, the hydraulic coupler speed: hydraulic coupler is a hydraulic transmission device, generally composed of the pump wheel and turbine, when the pump wheel in the prime mover driven under the rotation, in which the liquid is driven by the blade and rotation, in the Under the action of centrifugal force along the outer ring of the pump wheel into the turbine, in the same turn to the turbine blades to thrust, to drive the production machinery operation. Through different hydraulic (lubricants and turbines) to achieve speed.
Send your message to us
Frequency Inverter Single-phase 200V class 22KW
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords