Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: How to choose the right inverter?
1, constant power load During the operation of the load device, the power remains constant. Such as machine tools, cutting machines, paper machines and so on. For example: a marble cutting machine frequency conversion system, is a constant power load, load inertia, inverter selection configuration A power with the G-type machine, plus the braking unit and braking resistor.
Q: Motor 2 pole and 4 pole in the inverter with what set to show
Motor parameters, there must be a parameter "motor pole" of the bar.
Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
Because the frequency converter can reach 60 Hz frequency, while the three-phase power supply is the standard 50 Hz. So the inverter can make the motor speed faster than the rated 1500 rpm. The fastest up to about 1800 turn.
Q: Yaskawa inverter reported base blockade what is the reason?
Yasukawa compared garbage on the signal board on the small line of poor oxidation, and get like, this is a weak signal, and safety relays connected, do not use high-grade security circuit with a small line short, Yasukawa A 1000 factory is short for a long time after the oxidation of the base blockade
Q: Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
As you said the asynchronous motor after a very logarithmic change can be achieved on the speed of the "coarse tune", and then use the inverter is equivalent to add a "fine tune" device, but it seems a bit expensive, but to To see what you are on the occasion of the worthless.
Q: How to choose the inverter
I was doing the inverter, you choose the words, as long as 75KW can be selected, huh, huh, because the 1440 speed is fixed, the connection can be set in the inverter itself,
Q: Laptop power adapter how to detect?
No load voltage, DELL plug more special, the middle needle no load measurement is no voltage, the outer ring outer house and the wall only 19.5V voltage
Q: Do not the laptop directly connected to the power adapter?
3, the notebook internal circuit using low-voltage direct current work, if the direct use of 220V AC and its connection will burn the circuit in the low-voltage devices, which is absolutely prohibited, but also basic common sense. At the same time, its external power jack is also dedicated, and the AC outlet is different;
Q: How to learn the inverter debugging and design parameters
You can find the basic inverter manual, see a few times to try, under normal circumstances, the inverter on the use of manual functions such as research to understand that most of the applications are no problem.
Q: First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
In short, then connected to the bk-dk electrical appliances, is a resistor for the discharge effect

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords