Frequency Inverter Single-phase 200V class 185KW
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
- If there is a load, it may be less than the torque. So it can not run.
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
- Q: Laptop power adapter is broken, which brand is better domestic
- This is usually very compatible with the power adapter brand, you can only buy the original, or to the local computer market with a similar output power adapter can be,
- Q: Can the inverter stop intermittently during operation? If so, how to connect and set up
- One of these terminals is a common terminal, which leads from the common terminal and is connected to the corresponding terminal via the relay contact
- Q: Notebook plug in the power adapter lights, but can not open the machine
- This is a contradictory problem: First, the power adapter lights because the power is good, but does not mean that the computer is good; Second, can not open the machine with the power adapter is lit, it is your computer reasons. Recommendation: Check the computer hardware. Asked: But the battery can be used to start ah answer: Remove the battery plug in the adapter or put the battery installed plug in the adapter, if you can not open the machine, then it is a hardware conflict. The solution to the hardware conflict is that you try another adapter. Asked: the battery removed to die, but as long as there is a battery can answer: it shows that your adapter is bad. Asked: the more magical is plug in the adapter and the battery, the battery will not consume Answer: get you electronic city so that they give you a test. You can say to buy an adapter, and then try, you can use the words to buy, can not use the words and then think of other methods.
- Q: Can the laptop 1.3a power adapter be used on a 1.5a device?
- Absolutely can not try 1.5a! If you want your laptop to go wrong, then use it!
- Q: How to lift Yaskawa inverter base blockade?
- 2. If you can not solve the problem, be sure to seek the help of professionals. ? 3. If the base of the frequency converter blocks the input signal. While the base blockade, the inverter power tube is all closed, this one is mainly to protect the power tube. So the external input signal once resolved, the base block is automatically removed.
- Q: Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
- 6-pole motor synchronous speed of 1000 r / min, the actual motor speed is lower than the number, the actual speed is required to 500 r / min, then the motor and passive pulley diameter ratio of about 1: 1.6 or so, and then specific With the inverter to speed up to achieve the purpose, please refer to.
- Q: Delta VFD-A frequency converter motor number of poles set
- The frequency parameters of the inverter motor are not set, because the inverter will automatically detect the number of pole pairs of the motor during operation, and it will not need to be set.
- Q: What is the IGBT? Our inverter IGBT fried,
- Popular point is a switch, give him the signal to continue in accordance with a certain order switch, the DC through the switch into a change in the exchange of alternating current, different frequency.