• Frequency Inverter 15kw 380v 3 Phase AC Driver System 1
  • Frequency Inverter 15kw 380v 3 Phase AC Driver System 2
Frequency Inverter 15kw 380v 3 Phase AC Driver

Frequency Inverter 15kw 380v 3 Phase AC Driver

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

15kw 380v 3 phase frequency inverter for air compressor  



Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

1. Voltage class: 380V


2. Range of power: 0.4KW~450KW


3. Stable and reliable Control Mode


(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.


(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.


(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.

 

 


Reckoned to be the quality-oriented organization, we ensure that clients are served efficiently most appropriate manner. Clients appreciate our range for their quality and easy availability, besides the reasonable prices. Suggestions of clients are always welcomed and we make changes accordingly if required. We ensure that queries of clients are solved in minimum time-frame with appropriate solutions.



Frequency Inverter 15kw 380v 3 Phase AC Driver.jpg.JPG



Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.


Frequency Inverter 15kw 380v 3 Phase AC Driver


 

Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.

 

Applicable fields

Widely used in various fields such as metallurgy, petroleum, chemical industry, textile, power, construction material, coal, pharmacy food, paper making, plastic, printing & dying, lifting, cable making, washing, water supply, heat & ventilation, sewage treatment and son on. In addition the products can also be applicable to draw benches, mixers, extruders, winding machines, compressors, fans, pumps, grinding machines, belt conveyors, hoists and centrifuges.


Welcome your inquiry!

 

 

Looking forward to cooperating with you!


Q: A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
The upper limit frequency transferred to 25HZ, the number of poles changed to 2, try to run when the motor speed test
Q: What is the difference between variable frequency motor and variable speed motor?
The variable frequency motor requirements are high, are special motor, so the general motor can not use the inverter to speed. According to the above formula, it can be seen that increasing the frequency, the motor speed will be faster, reduce the frequency of the motor speed is slow, variable frequency motor core is also a special material, because the ferromagnetic material There is a saturation period, to the saturation period, regardless of whether the motor current increases, the motor will not continue to increase the intensity of the magnetic field,
Q: Asus notebook power adapter how to open
Can only be forced to open the pants and other things wrapped around the line on the line suggested that do not casually demolition
Q: The inverter is running independently
Principle of operation The main circuit is to provide asynchronous motor to the frequency conversion power supply part of the inverter, the main circuit of the inverter can be divided into two categories: voltage is the voltage source of the DC converter for the exchange of the inverter, DC circuit filter Is a capacitor. Current type is the current source of the DC into AC inverter, the DC loop filter is the inductance. It consists of three parts, the frequency power supply is converted to DC power "rectifier", absorbing in the converter and the inverter voltage ripple "smooth circuit." The basic composition of the rectifier unit: the fixed frequency of alternating current converted to direct current. High capacity capacitance: store converted energy. Inverter: high-power switching transistor array composed of electronic switches, the DC into different frequency, width, amplitude of the square wave. Controller: According to the set program work, control the amplitude of the output square wave and pulse width, so that superimposed as an approximate sine wave AC, drive AC motor.
Q: How to lift Yaskawa inverter base blockade?
Note: the base blockade is to deal with ul or ce such a special application of security agencies, meaning that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop loop more harsh, they will directly cut off the power power supply. In fact, it is a white protection function, if we are not difficult to find the analysis, when over-voltage or undercurrent, the panel will show BB alarm, BB is the base block, is the base blockade.
Q: What is the frequency of `30 points
AC are frequency, China is 50 Hz, is in a second amplitude of 50 times. To change this frequency, it is necessary to use some electronic components to change the current frequency. General frequency conversion for the tributary motor speed more. So that some equipment can be stepless. Principle, see the first floor just fine, copy the more detailed.
Q: The Schneider inverter reports the nlp command
Current transformers are also possible, or power supplies
Q: How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
Siemens frequency conversion dedicated input / output filter, reactor, you contact us but smell it, the quality is guaranteed. We look forward to cooperation.
Q: The motor is 2 pole with the inverter frequency to 50hz why the speed is only 1500 rpm
Motor speed formula: N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (s); F - power frequency (hz); P - pole pairs of motor rotating magnetic fields.
Q: Is the laptop power adapter hot?
Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.