flexible ducts INSULATION aluminum VBD flexible ducts aluminum foil
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 234 g/m
- Supply Capability:
- 234 g/m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Material
10m length aluminum insulation ventilation duct with low priceis made of aluminum foil +fiberglass+aluminum foi+steel wire
Product Feature
8 inch insulated flexible aluminum air duct heating and cooling systems following feature:
1.Size. (Customer's color requirement can be matched)
2.Color. (Customer's color can be fulfilled )
3.Non-toxic .Harmless to people even long time exposure
4.Excellent light transmission. transparent rate above 92%
5.Excellent weather resistance. performance can’t be change easily by Sunlight and Rain
6.Excellent Design.Personalized design and Human design with mordent concept
Product Advantages
8 inch insulated flexible aluminum air duct heating and cooling systems following advantages:
1.Material .environmentally friendly Acrylic
2.High Ruggedness.hard to attrit ,break and damage
3.Good anti-aging Properties .Long Using life Above 5 years
4.Strong Impact resistance .16 times than that of ordinary glass
5.Logo imprinting .Customer's Logo can be imprinted personally
6.OEM.ODM service. Satisfied related service can be offered in short time
7.Competitive price.Price at various level can cater your various requirement
8.Reasonable Delivery time.Fast to arrive at your office By air or Sea
9.Sample .Sample available for your proof and final decision
10.Trial Order are hotly welcome and allowed
- Q: My home is shaped like a square box. The four corners of the upper level have the roof pitch from the gables protruding into the rooms. The attic has no insulation and I need to insulate it. There is access from the attic to look down into the wall/ceiling that protrudes into the room. I can insulate the attic myself but the surface area of these protrusions is rather large. What would be the best way to get insulation down in there? Shoot the insulation in and poke it with a stick to make sure there is good coverage down in the wall space? The opening is about 6 inches high.Thanks.
- You need to have an air space between the roof and your insulation to prevent moisture build up on the inside and ice damming on the exterior. So you want to insulate the ceiling of the room, not the roof. For the angled protruding parts they make inserts that go between the joists to give 1-2" of air space under the roof and you can put insulation under that against the wall of the room. Remember that it's trapped air that insulates so don't overstuff when you push it in there. It sounds like you don't have access behind the vertical walls. You may need to break through the plaster between the studs to get in there and put insulation on the wall of the room and on top of the ceiling below. Then get some sheetrock and spackle to repair the hole you had to make, or you can make an insulated removable panel and use that area for storage. But don't store anything in there that can't take heat/cold.
- Q: 1) What thickness of rigid insulation is used on flat roofs?
- It depends on what R factor is called for , usually 1 & 1/2 inch on roof 2 &1/2 on walls ( usually statdard)
- Q: what effect does changing the pitch of a roof have on the insulation properties and durability of a roof?
- I'd have to agree with mj, your insulation in your ceiling is the major factor for heating and cooling , spec R-38 but if your going for gov. kick backs I think it's R-41 (17" of blown in fiberglass insulation). Roof pitch standard is 1' raise to 4' run, (really easy to re-roof & inexpencive). Advantages of a steep roof (less apt to have leakage problems with a worn roof, you get a few more yrs). When you have to replace that roof, price goes up for steepage.
- Q: I am specifically considering the re-roofing of a an older home where rafters were made with 2x4 or 2x6 and the rafter space (and possibly the attic space) does not allow sufficient space for insulation and proper ventilation behind the insulation. The old layers of roofing have to be removed in any event. At this point I am considering applying insulation boards on the existing sheathing and then a new layer of sheathing before the new roofing material. (similar to a SIP: structural insulated panel) The two issues I am concerned with is that the insulation can act as a vapor barrier. Would condensation potentially rot the lower sheathing. How is this avoided in SIP roofing panels? The second issue may be with fire regulations.
- The sip panels are vented depending on what thickness over all that you want. The last ones I used had 4 inches of rigid foam board then on top of that had 3" strips every 16" an inch thick which created an airspace. On top was 5/8 Osb. To create an affective air flow the fascia cannot plane through with the plywood at the bottom but fall just short of the 1" space. To cap it a oversized vented drip edge is used. You must also have a ridge vent for proper flow. These panels can near 100$. You can do it your own way like I do when building log cabins by laying 2" foam down first then lay 2x4 16 on center on top then finally your plywood. If you use CDX instead of Osb it will outlast it by 100%. Rigid foam insulation is not like batt-faced. Rfboard ins. Is used in boat hulls and even after being submerged for long periods of time will return to its original density and r-value. For obvious reasons batt ins. Will not. You won't have a moisture problem as long as you don't have a venting problem. If you are using high hat lighting don't let the cans touch your rigid ins. Tuck batt in softly around them TAKE THE PAPER OFF! By code if you have an interior wall 10or more ft. It must have a fireblock, simply a 2x4 turned flat between the studs. On your roof the ceiling you see inside, (most likely 7/8 tongue and groove boards) passes as the same. Good luck!
- Q: ... building code max. (R-50)???
- Anytime snow melts from a roof due to lost heat from the interior, or sun shining on the roof, but air is below freezing, icecycles will form. The real danger here is ice cycles that can fall when thawing and kill in extreme cases, AND ice dams can form forcing ice back up under shingles damaging roof. That is why it is often a good idea to install heat tape under the edge of roofs in areas that are prone to heavy freezes and snow.
- Q: a roof that is built with the insulation covering the waterproof membrain is ?
- a foolish product of college education in the building trades. it's pretty much taking over. real tradesmen saw that ship sink a while ago and are getting better at treading water.
- Q: i like to put a layer of sand in roofing instead of insulation. it's fireproof and insulates better. plus it's free. how much weight can ceiling board handle? I find about 15 inches poured into the roof works fine so far. Saves me about $1600 each house built
- first sand is very heavy and will probably exceed the loading on the roof and walls the extra reinforcing you would need to make the house SAFE would far outway any savings
- Q: i have roof insulation but if i add more to the required depth the bottom layer will get compressed. Will it still insulate?
- Compressed insulation is LESS effective than uncompressed insulation. It will still insulate more than not having it. If you are adding enough to actually compress the bottom layer, you have probably passed the point where additional insulation actually helps.
- Q: i have about 200 sq ft of odd shaped polystyrene foam (rigid) insulation between 3" and 5" thick. it's leftover from installing a flat roof on a commercial building. creative ideas anyone? grind it and use it as attic insulation in a home?thanks.
- Hey, Why not just sell the leftovers and make some dough instead? You can list them on craigslist or OKorder. Just a suggestion :) Regards, J
- Q: Can I install rigid insulation between roof decking and shingles on a sloped roof?
- No. The shingles are applied directly to the decking (over felt paper). Nailing through rigid insulation will either cause dips from driving the occaisional nail too far, or the shingles won't be nailed down tight and will blow off in the wind. Insulate under the decking.
Send your message to us
flexible ducts INSULATION aluminum VBD flexible ducts aluminum foil
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 234 g/m
- Supply Capability:
- 234 g/m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords