• Dry Transformer 31500-180000kVA System 1
  • Dry Transformer 31500-180000kVA System 2
  • Dry Transformer 31500-180000kVA System 3
Dry Transformer 31500-180000kVA

Dry Transformer 31500-180000kVA

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

           rated power:31500-180000kVA
rated voltage:11kv
pssed ISO9001and many certificate                


Specifications

rated power:31500-180000kVA
rated voltage:4kV
pssed ISO9001and many certificate
low losses

Product Description

11KV oil immersed on-load regulation power transformer has a seires of big changes in material, technical and construction with the characters of small size, light weight, high efficiency with low loss and low noise, stable opable operation which cutting down large number of loss from energy GRID and minising operation charge, improving the industrial economic benefit. It is used in power plant, transformer substation, big-sized and chemistry factory and etc. The product is according to National and IEC standards. Installation: Outdoor Ambient temperature: -30C-+40C Altitude: 1000m Relative Humidity: 90% (25C)

Rated capacity

(KVA)

Voltage combination

and tap range

(KV)

Vector group

S9 series

S10 series

No-load

Current

(%)

Short-circuit

Impedance

(%)

HV

LV

No-load loss

Load loss

No-load loss

Load loss

6300

110+/-2*2.5%

121+/-2*2.5%

6.3

6.6

10.5

11

Ynd11

9.3

36

8.4

34

0.77

10.5

8000

11.2

45

10.1

43

0.77

10000

13.2

53

11.9

50

0.72

12500

15.6

63

14.0

60

0.72

16000

18.8

77

17.0

73

0.67

20000

22.0

93

19.8

88

0.67

25000

26.0

110

23.4

105

0.62

31500

30.8

133

27.7

126

0.60

40000

36.8

156

33.1

148

0.56

50000

44.0

194

39.6

184

0.52

63000

52.0

234

46.8

222

0.48

75000

13.8

15.75

18

20

59.0

278

53.1

264

0.42

12-14

90000

68.0

320

61.2

304

0.38

120000

84.8

397

76.3

377

0.34

150000

100.2

472

90.2

448

0.30

180000

112.5

532

101.3

505

0.25


Q: What are the two power distribution equipment?
Primary equipment is the equipment used in the main system of transmission, transmission and distribution
Q: DC transmission equipment
Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
Q: What is the difference between power supply and distribution
The problem is you estimate from the injection test out the electric power, is the power system of power plant and the national grid is responsible for part of the design, the design of power plant and power lines, its design must be designed by a qualified electric power design institute
Q: Are electric wires and cables belong to distribution equipment?
Distribution equipment (Electrical Equipment) is in the electric power system of HV switchgear, generator, transformer, power circuit, circuit breaker, low voltage switch cabinet, distribution board, switch box, control box and other equipment collectively.
Q: High and low voltage distribution equipment
High voltage distribution equipment: high voltage fuse; high voltage isolation switch; high voltage load switch; high voltage circuit breaker.
Q: An introduction to the interpretation of flexible AC transmission systems
The parallel compensation device, such as static var compensator (SVC), thyristor controlled braking resistor (TCBR), static
Q: Rural high voltage transmission line equipment ownership
High voltage transmission line, one end of the power plant (power), the other end of the number of users in the use of electricity, of course, the current
Q: Transmission and transformation equipment
Transmission and transformation of basic electrical equipment, including the main wire, transformers, switchgear, high voltage insulators, etc.
Q: Difference between distribution voltage and supply voltage
In general, the city substation will be reduced to 10KV 110KV to the electrical terminal.
Q: CHINT group in the transmission and distribution equipment to do it?
The national grid is not purchasing some equipment of CHINT, CHINT group is now very powerful