High Voltage Vertical Break Disconnector and Isolator
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1. 145KV Disconnector and Isolator
2. KEMA test report
3. ISO quality certificate
4. Good quality and after-sales service
General introduction :
GW4-40.5/72.5/126/145/170/252 Ⅲ Series, two columns, horizontally rotating type, HV, AC, disconnector
Product classifications and Main Technical Specifications :
1), Product classification
Voltage level: 40.5kV, 72.5kV, 126kV, 145kV, 170kV, 252kV.
Current level: 630A,1250A, 2000A, 2500A,3150A, 4000A.
Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches.
2), Main Technical Specifications
Technical Specifications | Product Type | GW4-40.5Ⅲ | GW4-72.5Ⅲ | GW4-126Ⅲ |
Rated voltage kV | 40.5 | 72.5 | 126 | |
The rated current A | 1250, 2000, 3150, 4000 | |||
Disconnector | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Grounding switch | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Rated short-time power frequency withstand voltage (RMS) kV | to earth | 95 | 160 | 230 |
across open contacts | 118 | 200 | 230+70 | |
Rated lightning impulse withstand voltage (peak) kV | to earth | 185 | 350 | 550 |
across open contacts | 215 | 410 | 550+100 | |
minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector | 53 | 94 | 164 | |
rated terminal static mechanic load N | longitudinal level | 1000 | 1000 | 1000, 1250 |
Horizontal level | 750 | 750 | 750 | |
Vertical force | 1000 | 1000 | 1000 | |
switching micro-capacitance current A | 2 | 2 | 2 | |
switching micro-inductance current A | 1 | 1 | 1 | |
switching busbar for current transfer A (busbar transfer voltage 100V) | 400V, 2500A, 100 times | |||
Radio interference level | less than 500 μV | |||
Mechanical life | 3000 | 3000 | 3000 | |
single pole weight (kg) | 120 | 200 | 260 | |
Note: All applied to an altitude of 2000m |
Technical Specifications | GW4-145Ⅲ | GW4-170Ⅲ | GW4-252Ⅲ | |
Rated voltage kV | 145 | 170 | 252 | |
The rated current A | 1250, 2000, 3150, 4000 | |||
Disconnector | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Grounding switch | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Rated short-time power frequency withstand voltage (RMS) kV | to earth | 275 | 325 | 460 |
across open contacts | 315 | 375 | 460+145 | |
Rated lightning impulse withstand voltage (peak) kV | to earth | 650 | 750 | 1050 |
across open contacts | 750 | 860 | 1050+200 | |
minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector | 188 | 221 | 291 | |
rated terminal static mechanic load N | longitudinal level | 1000, 1250 | 1500 | 1500 |
Horizontal level | 750 | 1000 | 1000 | |
Vertical force | 1250 | 1250 | 1250 | |
switching micro-capacitance current A | 2 | 2 | 2 | |
switching micro-inductance current A | 1 | 1 | 1 | |
switching busbar for current transfer A (busbar transfer voltage 100V) | 400V, 2500A, 100 times | |||
Radio interference level | less than 500 μV | |||
Mechanical life (times) | 3000 | 3000 | 3000 | |
single pole weight (kg) | 300 | 326 | 900 | |
Note: All applied to an altitude of 2000m |
- Q: What are the two power distribution equipment?
- Such as generator, transformer, circuit breaker, isolating switch, bus, power cable and transmission lines, etc..
- Q: What are the distribution network equipment
- The transmission function of the power plants issued by the electricity to power consumption areas, or between adjacent grid power to send each other
- Q: What are the general requirements for working on distribution equipment?
- When the high voltage line is not cut off, the person in charge of the work shall explain to the whole staff that there is electricity on the line and strengthen the monitoring
- Q: Transmission system and distribution system
- Distribution system is the power supply to the distribution load for the purpose of the general voltage level of not more than 10KV
- Q: What is the difference between power supply and distribution
- The problem is you estimate from the injection test out the electric power, is the power system of power plant and the national grid is responsible for part of the design, the design of power plant and power lines, its design must be designed by a qualified electric power design institute
- Q: An introduction to the interpretation of flexible AC transmission systems
- The parallel compensation device, such as static var compensator (SVC), thyristor controlled braking resistor (TCBR), static
- Q: Transmission and transformation equipment
- Transmission and transformation of basic electrical equipment, including the main wire, transformers, switchgear, high voltage insulators, etc.
- Q: Difference between distribution voltage and supply voltage
- In general, the city substation will be reduced to 10KV 110KV to the electrical terminal.
- Q: Power distribution equipment should be prepared before the blackout?
- electrician received power outage notice, pull down the knife switch, accept fuse.
- Q: CHINT group in the transmission and distribution equipment to do it?
- Really is the leader in the domestic electrical industry!
Send your message to us
High Voltage Vertical Break Disconnector and Isolator
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords