High reliability MCR
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
High reliability;
Free of maintenance;
Long time service;
Infinitely adjustment;
Directly run in any voltage
1. MCR-SVC is composed of MCR(Magnetic-valve Controlled Reactor), excitation system, filter capacitor bank and control&monitor system. MCR is made of high quality silicon sheet and varnished wire with low temperature-rise design and high reliability, which can normally operate for 20 years. Regular routine inspection can make sure of stable operation for a long time with small working, easy maintenance and low cost. The body is oil-immersed reactor, outdoor installed. Foundation construction cost is small.
MCR Body Excitation Device
Control And Monitoring System
2.All guarantees excitement system reliable and safe. Triggering system of electronics elements is in light trigger method and better isolation is between main circuit and control circuit with super interference proof ability.
3.Digit control system occupies features of short response time and higher reliability. Friendly human-to -machine interface is available between control system and excitation system, easy for customers to use and repair.
- Q: DC transmission equipment
- Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
- Q: What is the power equipment in the distribution room?
- which is mainly used for the distribution of the electric energy of the low-voltage users, and the utility model is provided with a medium voltage input line (a small number of outlets)
- Q: Transmission system and distribution system
- Distribution system is the power supply to the distribution load for the purpose of the general voltage level of not more than 10KV
- Q: What is the difference between power supply and distribution
- The problem is you estimate from the injection test out the electric power, is the power system of power plant and the national grid is responsible for part of the design, the design of power plant and power lines, its design must be designed by a qualified electric power design institute
- Q: Are electric wires and cables belong to distribution equipment?
- Distribution equipment (Electrical Equipment) is in the electric power system of HV switchgear, generator, transformer, power circuit, circuit breaker, low voltage switch cabinet, distribution board, switch box, control box and other equipment collectively.
- Q: Distribution system equipment classification
- Special equipment used in a certain industry, such as artillery, automatic teller machine, steel making furnace, etc.
- Q: Transmission lines are not electrical equipment?
- Transmission lines in the power transmission project belongs to the carrier, belonging to the power cable category, should not be called equipment
- Q: An introduction to the interpretation of flexible AC transmission systems
- synchronous compensator (STATCOM), reactive power distribution is mainly used to improve the system, to adjust voltage and improve the voltage stability of the system;
- Q: Transmission and transformation equipment
- Transmission and transformation of basic electrical equipment, including the main wire, transformers, switchgear, high voltage insulators, etc.
- Q: Difference between distribution voltage and supply voltage
- Supply voltage refers to the supply point of the line voltage or phase voltage.
Send your message to us
High reliability MCR
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches