Specifications
the distribution power device with 12kv, three-phase, AC, 50HZ, used in the single bus and segmented system.
Standard:
GB3906-2006; DL/T 404-1997.
Usage:
Used in the single bus power system with 3.6-12kv, AC, three-phase, 50HZ to accept and distribute power, control, protect and monitor the circuit.
The technical parameter:
Item | Unit | Parameter | |
rated voltage | kV | 3.6,7.2 ,12 | |
rated current | A | 1250,1600,2000,2500,3150 | |
rated short-circuit drop-out current | kA | 31.5,40 | |
4Srated heat steady current | kA | 31.5, 40 | |
rated dynamic current | kA | 80 ,100 | |
rated lighting impulse withstand voltage | kV | 75 | |
Rated 1min power frequency withstand voltage | kV | 42 | |
auxiliary circuit power frequency withstand voltage | V | 2000 | |
auxiliary circuit control voltage | V | DC110,220 ; AC110,220 | |
the level of protection of Shell and cabinet | IP4X | ||
Size of cabinet | Middle-type | mm | 900×1775×2050(800×1775×2050) |
Landing middle-type | mm | 840×1775×2200(1000×1775×2200) |
- Q:What is the difference between power supply and distribution
- Power supply and distribution is part of the use of general by the Architectural Design Institute of electrical professional
- Q:Distribution system equipment classification
- Electronic equipment - named meaning, is mainly composed of electronic components
- Q:What is the role of transmission system and distribution system in power grid
- The power load center is more concentrated in the industrial zone and the big city,
- Q:What is the power equipment in the distribution room?
- 10kV and below voltage rating equipment, divided into high voltage distribution room and low-voltage distribution room
- Q:CHINT group in the transmission and distribution equipment to do it?
- not only is the previous low, now from energy production to transportation to use to control a complete solution.
- Q:AC distribution equipment including distribution box
- Connect the power supply, transformer, converter and other equipment for load distribution box, and monitoring
- Q:An introduction to the interpretation of flexible AC transmission systems
- synchronous compensator (STATCOM), reactive power distribution is mainly used to improve the system, to adjust voltage and improve the voltage stability of the system;
- Q:What are the distribution network equipment
- suburbs, towns and rural areas, further allocation and supply industry, agriculture, commerce, industry and residents with special needs for electricity secto
- Q:High and low voltage distribution equipment
- High voltage distribution equipment: high voltage fuse; high voltage isolation switch; high voltage load switch; high voltage circuit breaker.
- Q:Power distribution equipment should be prepared before the blackout?
- electrician received power outage notice, pull down the knife switch, accept fuse.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Switchgear Used in the single bus power system
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches