Diaphram Pump(DP-60)
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications:
Perfect for caravans, boats, motorbikes, trucks and camping. Use it with fresh or salt water with your deck wash or to run your toilet or shower. These pumps automatically turn themselves on and off when you turn the tap on and off. Comes with filter and fittings. These pump are for intermittent use only.
A great pump for those country folk, with a small family, on tank water who only need to boost the pressure from a tank next to the house.
We have tested these pumps and found they will operate to a 2 metre suction lift and 5 metre head with no problems.
1.Maximum torque and operating efficiency/higher operating pressure and/or lower amperage than competitive pumps
2.Long life, no leaks, strong corrosion resistant
3.12/24 VDC and 115/220 VAC motors standard (consult factory for other voltages)
4.Quality components for extreme performance
5.Numerous fitting options for greater mounting flexibility
6.Voltage:12V/24V DC Diaphragm Pump,115V/230V AC Diaphragm pump
7. Expecially suitable for marine and recreation vehicle, such as boat and ship.Also suitable for Agriculture sprayer
Features
Lightweight and made from non corroding materials
Self priming
Run dry Protection
Easy to install
No maintenance
Simple to operate
Low power consumption
12 months warranty
Automatically turns on and off
Comes with filter and fittings
How a Pump Works
The pump is driven by an AC or DC motor
In front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled hrough the inlet, through the various valve chamber check valves to the outlet he volume of flow is determined by several factors including: the number and size of the pump chambers,cam offset, operating pressure, fluid viscosity.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
- Q: What does the pump mortar do?
- 1: 2 cement mortar or cement mortar with the same proportion of other components except coarse aggregate in the concrete, the pump piston and the inner wall of the pipeline are fully lubricated, and a layer of lubricating film is formed
- Q: What is the pumping property of concrete?
- Pumping capacity means that fresh concrete can be transported by concrete pump, and concrete construction can be carried out with high efficiency. 'pumping' is a qualitative statement
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
- Q: How many pumps does the 80cm tank use?
- For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
- Q: Why is the sewage pump device coupler?
- Advantages of installation and arrangement of sewage pump coupling:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device under the condition of fixed installation, such as pump fault maintenance personnel need to unscrew the screw pump lifting water, repair, or other small pump to pump the water down perfect maintenance, if the water is dirty, it would be difficult for people to go to the next, then the overhaul had great difficulty.
- Q: What is an industrial water pump?
- Classification by usagePump, circulating pump, fire pump, pressure test pump, sewage pump, metering pump, sanitary pump, dosing pump, pump, pump, gelatinization defoaming pump, flow pump, oil pump, water pump, drainage pump, drainage pump, dredging pump, sprinkler pump, booster pump, high pressure pump, heat pump high temperature, low temperature, pump pump, condensate pump, heat pump, cooling pump, heating pump, deep well pump, analgesic pump, pump, pump, chemotherapy, blood pump material pumping pump, pump, pump, sulfur removal, shearing grinding pump fuel pump, pump, pump, quillback bath source heat pump, filter pump oxygen pump, pump, shampoo, injection pump, air pump, gas pump, pump, pump, art odorization pump chopped
- Q: Filter backwash pump for what use, what is the principle of work ah?
- But the reverse cleaning can not completely regenerate the filter medium, or there will be some impurities remain, when the regeneration of residual impurities (pressure drop) to set the value, you need to replace the filter (filter media).
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.