• DC Solar Submersible Pump for Irrigation System 1
DC Solar Submersible Pump for Irrigation

DC Solar Submersible Pump for Irrigation

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.New energy-saving solar pump
2.DC24V without inverter
3.Pumping lift: 5-100 M
4.Flow rate: 10L/min or 30L/min

Applictaion:

1. Desert control, sea water desalinization, agricultural irrigation.

2. Daily water supply, forest irrigation, city waterscape.

3. Landscape fountains, pasture animal husbandry.

4.Islands' water supply, wastewater treatment engineering

  • By CE Certification

  • DC input, wide voltage(working voltage: 12-18V)

  • Built-in MPPT which can make the best use of the solar energy.

  • The pump can be directly connected to solar panels in sunshine without controller.

  • The pump include Over-voltage protection / Under-voltage protection / Over-current protection / Over-load protection.

  • Environmental protection, achieve zero carbon dioxide emissions.

  • Solved the water shortage problems of the area without electricity

  • Tank/Cistern filling

  • Village or family water supply

  • Water supply for farm

  • Garden/courtyard irrigation systems

  • Livestock watering

  • Swimming pool filling

  • Fountains

  • Water supply for bivouac or camping car

  • Solar water circulating system

  • Renewable energy projects

  • Delivery time for order within available stock is in 7days

  • Delivery time for order without available stock is in 15days

Q: Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q: What is a solution pump?
(4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
Q: Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q: Why is the sewage pump device coupler?
Automatic coupling installation of sewage pump is a sewage pump with automatic coupler and a guide rod guide chain fixed installation, convenient maintenance, manual maintenance can be directly hung up by the pump coupling device, ordinary sewage pump is generally Mobile
Q: What is an industrial water pump?
The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q: What's the difference between a concrete pump and a concrete pump truck?
Concrete conveyor pump height and distance can reach hundreds of meters, which is far more than pumping vehicles, but it needs cloth tube, not flexible enough. Less investment.Pump car use more flexible, higher investment.
Q: Filter backwash pump for what use, what is the principle of work ah?
When the filter is in normal operation, the impurity will be trapped in the upstream of the filter (filter medium). As the accumulation of impurities, the filter media will be blocked, and the direct performance is that the circulation will decrease. Usually, when the flow drops to a set point (the industry is usually judged by the pressure drop),
Q: How to maintain and repair the booster pump of pipeline pump?
I. installationAssembly and disassembly1. scrub all the spare parts to be cleaned.2. mechanical seals are installed on the main shaft of the motor, and a small amount of clean turbine oil or 20 oil is added to the surface of the mechanical seal.
Q: What is the difference between centrifugal pump and self suction pump? Which is better?
In order to prevent the filling liquid into the pump shell because of gravity flow in the low groove, in the pump suction pipe at the entrance of a non-return valve (valve); if the location of the pump below the liquid level in the tank, then start without irrigation pump.Self-priming pump is a self-priming centrifugal pump, centrifugal pump is a kind of.Specific choice of a pump, depending on your specific parameters and conditions of use.
Q: What are the failures and causes of the replacement of the fuel pump assembly?
Common troubles of gasoline pump:Gasoline pump supply shortage of gasoline pump supply depends on the pump membrane stroke, stroke, pump oil should be more; however, the amount of gasoline pump oil pump will reduce the consumption of gasoline engine, and the fuel pump is inevitable, if the engine fuel consumption, but the actual amount of oil is less, this situation is the amount of oil in the petrol pump, there will be a float chamber of a carburetor oil level is reduced, the engine power shortage.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches