1. Description

  1>Horizontal multistage design with stainless steel stamping welding impeller and diffuser,three different type of choice.

  2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.

  3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.

 

2. Application

  1>cooling water system

  2>agriculture

  3>domestic water supply

  4>general industrial services

  5>washing

  6>enviroment protection

 

3. Performance range

  capacity: Q up to 32m3/h

  head H up to 110 degree centigrade

  speed: n 2900rpm or 3500rpm

  power: P up to 55kw *2

 

4. Standard material

  All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be  made of cast iron on request too.

 

5. RFQ

1> What's the difference for CHL and CHLF(T) type?

    CHL pumps have an inlet and outlet chamber which is made by stainless steel. CHLF(T) is just the section type. 

2> Do you have any variable motor for these pumps?

     Yes, we have. For the variable motor, the frequence can be changed as the customers' request. If the range is between 30~50Hz, the fan can be just connected with the shaft. And if the frequency is below 30Hz, then the fan has to have another separated power. The variable speed motor would be used for solar energy or some other similar situation with the unstable power. 

3> How about the Delivery time?

     Actually, this would be depending on the quantity. If it is just small order, 1 week would be fine. For bigger quantity, the delivery would be also less then 20 days. But for the varible speed ones, it will be taking some more time, normally it will be more than a month.  

CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pumps With High Quality

CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pumps With High Quality


Q: What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q: What are the ways of hydraulic pumps?
There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
Q: What are the causes of pump shock?
Troubleshooting cause1. bearing damage, replace new bearings2., coupling pin, bolt damage, rubber column or metal bolt wear, change
Q: Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q: Does vacuum pump oil belong to dangerous goods?
Of flammable substances, but not included in dangerous goods!Does not belong to dangerous goods,
Q: Water pump does not produce water, what are the reasons?
1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
Q: Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q: Significance of water pump model ISO50-160
Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.