• Chinsc 11kw 3 phase variable frequency drive System 1
  • Chinsc 11kw 3 phase variable frequency drive System 2
Chinsc 11kw 3 phase variable frequency drive

Chinsc 11kw 3 phase variable frequency drive

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Specifications

1.Brand name:CHINSC 
2.11kw variable frequency drive 
3.Three phase 380v 
4.Frequency: 0.1-600hz 
5.Short delivery time 

11kw variable frequency drive with soft starter  

 

Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

  

1. Voltage class: 380V

  

2. Range of power: 0.4KW~450KW

  

3. Stable and reliable Control Mode

  

(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.

  

(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

 

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.

  

(3) Torque control: Fast torque response, <20ms, precision torque: <5%, applied to winding, drawing and other occasions.

 

Technical Parameter

 

VFD Capacity

Input Voltage (V)

Power Capacity(KVA)

Input Current (A)

Output Current (A)

Adapter Motor(KW)

G7.5/P11T4B

3 Phase 380V Range:-15%~20%

11.0

20.5

18/27

7.5/11

G11/P15T4B

17.0

26.0

27/34

11/15

   

Factory Overview

 


Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

 

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

 

c. Packing                             

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.

 

 


Q:What parts of the inverter composition
Simply put, the inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit
Q:What is the laptop adapter
1, laptop adapter, that is, laptop charger. The traditional notebook charger can only output a single voltage to a type of notebook computer charging, the industry said that the traditional laptop power adapter for the single-band notebook charger.
Q:55 瓩 4 pole motor with a frequency of one hour can save much electricity
It depends on what type of equipment you use, the average energy-saving fan pumps, about 25-40 between; generic class is based on the frequency you use to decide, according to the frequency you use with 50 Hz Compared to energy saving.
Q:A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
If it is normal V / F control, then do not need to modify too many parameters to limit the frequency limit of 50%
Q:Laptop power adapter aging
This is not much relationship with the adapter, is your laptop internal hardware overheating, leading to self-protection open and shut down.
Q:What is the characteristic of the variable pole speed method?
Three-phase asynchronous motor speed formula: n = 60f / p (1-s) From the above equation can be seen, change the power supply frequency f, the motor pole p and slip rate s can achieve the purpose of changing the speed. From the nature of the speed point of view, different speed control mode is nothing more than to change the AC motor synchronous speed or do not change the synchronous turn two. In the production machinery is widely used does not change the synchronous speed of the speed control method There are winding motor rotor resistance, chopping speed, cascade speed and the application of electromagnetic slip clutch, hydraulic coupling, oil film clutch, etc. Speed ??control. Change the synchronous speed of the stator to change the number of pole pairs of multi-speed motor, change the stator voltage, the frequency of the frequency control can not change the motor speed and so on. From the energy point of view of the speed control point of view, there are two methods of efficient speed control and inefficient speed control: high speed control when the slip rate is constant, so no slip loss, such as multi-speed motor, frequency control As well as the speed loss can be recovered speed control methods (such as cascade speed, etc.). There are slip loss of the speed control method is a low efficiency, such as the rotor string resistance control method, the energy loss in the rotor circuit; electromagnetic clutch speed control method, the energy loss in the clutch coil; hydraulic coupling speed , Energy loss in the oil of the hydraulic coupling. In general, the slip loss increases with the speed range, if the speed range is not large, the energy loss is very small.
Q:Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
Is it right? The next manual to see do not understand
Q:Laptop power adapter current is not the same alternative?
The adapter is the voltage source, the actual output current depends on the size of the load resistance,
Q:B2b frequency how to speed
How does changing the power frequency to change the speed of the motor? When the motor is connected to the power supply to drive the normal operation of the load, at this time to change the power frequency, such as the current frequency down, the motor armature rotating magnetic field speed will decline, the rotor conductor cutting magnetic field speed decreases, turn from the induced potential , The rotor current decreases, the torque decreases, the load on the shaft does not change, the torque will be less than the load resistance torque, the motor rotor speed decreases, the rotor conductor cutting the magnetic field line speed increases, the rotor induced potential increases, the rotor current increases, The torque rises until it is equal to the load resistance torque, and the speed is smaller than the original. After stabilizing the work, the torque of the motor is the same as that of the original. (The motor torque is the same as the load torque, the load is constant and the motor torque is not changed)
Q:What is the common COM point of the PLC and the inverter? Is it positive?
Generally refers to the common, and most of the negative

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords