• Booster Pump for Pump Station River Pumping System 1
  • Booster Pump for Pump Station River Pumping System 2
  • Booster Pump for Pump Station River Pumping System 3
Booster Pump for Pump Station River Pumping

Booster Pump for Pump Station River Pumping

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                           Booster Pump for Pump Station River Pumping

1.Structure of Booster Pump for Pump Station River Pumping Description

The high presuure boiler feed multistage water pump is a horizontal multistage centrifugal pump and suitable for transporting pure water,both ends of it are supported,the casing portion is a senctional form,it is connected and actuated by motor via a resilient clutch.From the driven direction,the pump rotated direction is clockwise.

2.Main Features of Booster Pump for Pump Station River Pumping

• High Effiency

•Low noise

Long life, OEM and ODM are welcomed.

3.Booster Pump for Pump Station River Pumping Images

High Pressure Boiler Feed Multistage Water Pump

4.Horizontal Multistage Centrifugal Water Pump Specification

Material

 

Cast iron and as customer's request

Temperature

 

Less than 150°C

Flow rate

              3.75-300m3/h

Head

75-1000m

Medium temperature

0 ~170°C

Operation pressure

≤40 bars

5.FAQ

①What is the applications?

Power Station,Industry Water Supply

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.


Q: The function of centrifugal pump
The basic structure of the centrifugal pump is composed of six parts, namely: impeller, pump body, pump shaft, bearing, sealing ring, stuffing box.1, the impeller is the core part of the centrifugal pump, it is high speed, large output, the impeller blade and play a major role in the impeller before assembly, through the static equilibrium experiment. The inside and outside surfaces of the impeller are required to be smooth, so as to reduce the friction loss of the water flow.
Q: Concrete pump 125 pipe wall thickness
Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
Q: What kind of motor does the hydraulic pump need?
The motor should be determined according to the work environment, such as 220V.12V.24V.72V or 380V, and then the power.Calculation of actual oil pump power:
Q: What's the difference between non negative pressure and variable frequency water pump?
Re pressure to a given pressure pressure zone water supply, than frequency conversion water pump energy savingFrom a health perspective, a water tank variable frequency water pump, water tank and the atmosphere, easy occurrence of water pollution two, no negative pressure equipment without negative pressure tank and pump and valve fittings etc., no water tank, the whole process of water supply of water is completed in a closed system, with air contact to avoid two pollution problems water supply.From the management point of view, no negative pressure is fully automatic intelligent operation, reduce management costs, no water tank, reducing the trouble of tank cleaning. No negative pressure is the upgrading of variable frequency water pump products
Q: What are the constant pressure pumps?
CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
Q: How can I buy a pump?
3 、 mechanical requirements of high reliability, low noise, vibration.4, the correct calculation of pump procurement costs, the pump manufacturer to inspect, requiring good quality equipment, good after-sales service, spare parts can be timely supply.The micro pump and the motive of the mechanical energy or other external energy transmitted to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.The technical parameters of pump performance include flow, suction, lift, shaft power, water power, efficiency and so on.
Q: Suction stroke and lift of water pump
For example: there is a kind of water pump, the model is called "BSP" series, the volume is not large, but the nominal suction process can be 4 meters, it can not add water to 4 meters, it is considered to be relatively high in the micro pumpIn micro pumps, not all pumps have self-priming capacity ("suction stroke")Some centrifugal pumps there is no self-priming ability to use must first do add water. Although some micro pump with self absorption capacity, but "suction" are often the subject of "and the water inlet pipe in all air, can smoke the vertical height of water gap, even only half not so. The pump selection, the absorption process is a relatively important parameter.
Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
Centrifugal pump, and is a very common method of centrifugal pump, flow with the head (or pressure) increases, off a small valve resistance increases, the pump head should be increased, then the flow decreased, whereas open valve flow increase
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q: How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords