Main Properties & Typical Values
Test Items | Unit | Test Method | Standard | Typical value |
Tensile strength | MPa | GB/T1040.3 | 13.0 | 26.4 |
Elongation at break | % | GB/T1040.3 | 300 | 524 |
Heat ageing properties (Test temperature 135℃, 168hr) Maximum tensile strength change Maximum elongation at break change |
% % | GB/T8815 |
±20 ±20 |
10.3 2.1 |
Heat elongation (200±3)℃x15minx0.2MPa) Maximum elongation change under load Maximum permanent elongation change after cooled |
% % | GB/T2951 |
≤80 ≤5 |
45 -6 |
Impact brittle temp. (-76℃) Impact brittle | Failure no. | GB/T5470 |
≤15/30 |
pass |
Pressure crack test F50 | hr | GB/T2951 | 1000h | pass |
Artificial atmosphere ageing properties: Ageing After 42days, Maximum tensile strength change Maximum elongation at break change Ageing after 42days vs. after 21days Maximum tensile strength change Maximum elongation at break change |
% %
% % | GB/T14049 |
±30 ±30 ±15 ±15 |
10 2.7 6 -5 |
Dielectric Strength | MV/m | GB/T1408.1 | ≥22 | 39 |
Dielectric loss factor 50Hz, 20℃ | -- | GB/T1409 | ≤1×10-3 | 5.2×10-4 |
Volume resistance (20℃) | Ω·m | GB/T1410 | ≥5×1013 | 1.1×1014 |
Note: All typical values were tested by press moulding sample under the condition of 180±2 ℃,15min, and pressure over 15Mpa, then cooling to room temperature.
- Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
- There are [the top of the machine can be broken off the ball can be hit by Jiu turtle snow box video output cable and DVD video output line] into a junction box, and then through the sub-box toggle switch to select the 'set-top box' or 'DVD'; This junction box outputs a wire connection device or is connected to a TV.
- Q: What brand of cable is good, what are the top ten brands of wires?
- Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
- Q: Apple phone display cable or accessories not certified how to do
- Indicating that your Apple data cable is not original, no effect, re-plug the general and you can use the.
- Q: What machinery is required to make wire and cable?
- Oh, the pipeline is poured before the layout according to the design drawings.
- Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
- Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
- Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- Data line pregnant, I also appeared once for a data line on it.
- Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
- The second floor of the formula is correct, my space also have this formula, with armor and no armor in the current no difference, there are differences in the installation, usually buried to armor, overhead or bridge without armor, you give the model is not Armor, YJV-4 * 240 without armor, YJV-22-4 * 240 armor,
- Q: Wire and cable CCC product consistency is what
- PVC line, the market is better with plastic, plastic, . Wantong, etc., if only home improvement, then the brand requirements do not need so high. Small brands are the same, we see the quality. Network cable, then preferred Ann or TCL.
- Q: Apple 6 Charging Why always show this cable has not yet been certified
- Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
- Q: Why does the bird stand on the wire without anything, but if people touch it,
- Is not the home of the bus box? Generally put a cat, a router, a power outlet, two transformers, the other is the network cable and telephone, the key space to be enough
Send your message to us
Grey XLPE Compound for 10KV and Below Aerial Hanging Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000000kgs kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords