pecifications of Cable Conductor of Cable Conductor HS156
ACSR Conductor Cable
1.Conductor:Hard drawn aluminium wire
2.Steel core:Galvanized steel wire,solid or concentric stranded
ACSR Conductor, Aluminium Conductor Steel Reinforced or Cable Conductor HS156
Aluminum Conductors Steel Reinforced ACSR ASTM B 232 of Cable Conductor HS156
Area |
Stranding and wire diameter |
Approx. overall diameter |
Weight |
Nominal breaking load |
Nominal DC resistance at 20 deg. | ||||||
Nominal |
Alum. |
Steel |
Total |
Alum. |
Steel |
Alum. |
Steel |
Total | |||
AWGorMCM |
mm2 |
mm2 |
mm2 |
mm |
mm |
mm |
Kg/km |
Kg/km |
Kg/km |
kN |
Ohm/km |
1272 |
644.51 |
81.68 |
726.19 |
54/3.90 |
19/2.34 |
35.10 |
1795 |
638 |
2433 |
194.00 |
0.04516 |
1272 |
644.51 |
17.87 |
662.38 |
36/4.78 |
1/4.78 |
33.42 |
1777 |
140 |
1917 |
115.85 |
0.04472 |
1351.5 |
684.84 |
47.10 |
731.94 |
45/4.40 |
7/2.92 |
35.16 |
1898 |
368 |
2266 |
160.70 |
0.04230 |
1351.5 |
684.84 |
86.71 |
771.55 |
54/4.02 |
19/2.41 |
36.17 |
1906 |
679 |
2585 |
206.05 |
0.04250 |
1431 |
725.10 |
50.32 |
775.42 |
45/4.53 |
7/3.02 |
36.24 |
2009 |
393 |
2402 |
170.71 |
0.03994 |
1431 |
725.10 |
91.87 |
816.97 |
54/4.14 |
19/2.48 |
37.24 |
2019 |
719 |
2738 |
218.24 |
0.04013 |
1510.5 |
765.35 |
52.90 |
818.25 |
45/4.65 |
7/3.10 |
37.20 |
2120 |
414 |
2534 |
177.89 |
0.03784 |
1510.5 |
765.35 |
96.84 |
862.19 |
54/4.25 |
19/2.55 |
38.25 |
2131 |
759 |
2890 |
230.20 |
0.03802 |
1590 |
805.68 |
55.48 |
861.16 |
45/4.77 |
7/3.18 |
38.16 |
2232 |
435 |
2667 |
187.02 |
0.03595 |
1590 |
805.68 |
102.13 |
907.81 |
54/4.36 |
19/2.62 |
39.26 |
2243 |
799 |
3042 |
242.55 |
0.03613 |
80 |
40.52 |
14.13 |
54.65 |
8/2.54 |
1/4.24 |
9.32 |
112 |
110 |
222 |
23.60 |
0.7115 |
101.8 |
51.61 |
30.06 |
81.67 |
12/2.34 |
7/2.34 |
11.71 |
143 |
235 |
378 |
41.75 |
0.5613 |
110.8 |
56.13 |
32.77 |
88.90 |
12/2.44 |
7/2.44 |
12.22 |
156 |
256 |
412 |
51.25 |
0.5161 |
134.6 |
68.19 |
39.81 |
108.00 |
12/2.69 |
7/2.69 |
13.46 |
189 |
311 |
500 |
61.70 |
0.4248 |
159 |
80.58 |
46.97 |
127.55 |
12/2.92 |
7/2.92 |
14.63 |
223 |
367 |
590 |
72.55 |
0.3595 |
176.9 |
89.48 |
52.19 |
141.67 |
12/3.08 |
7/3.08 |
15.42 |
248 |
409 |
657 |
78.50 |
0.3237 |
190.8 |
96.71 |
56.39 |
153.10 |
12/3.20 |
7/3.20 |
16.03 |
268 |
441 |
709 |
84.80 |
0.2995 |
203.2 |
102.97 |
91.87 |
194.84 |
16/2.86 |
19/2.48 |
18.14 |
285 |
722 |
1007 |
128.80 |
0.2813 |
211.8 |
107.10 |
62.45 |
169.55 |
12/3.37 |
7/3.37 |
16.84 |
297 |
488 |
785 |
93.90 |
- Q: Apple 6splus charge may not support this accessories how to do more
- Sometimes no way, the problem to the owners to solve the common, must wear, the owners agreed
- Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
- Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
- Q: What is the difference between wires and cables?
- The introduction of the device in the form of: sealing ring (sealing ring is to achieve the required protection level of the shell and the use of cash-saving brush to help find the silent material or elastic material parts) type of introduction device; casting solidified packing seal Type introduction device; metal seal ring introduction device
- Q: Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
- Wipe with water that day. You can also use ink thinner
- Q: What is the difference between "wire" and "cable"?
- Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
- Q: Apple 6 Charging Why always show this cable has not yet been certified
- Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
- Q: IPhone6 This cable or accessories have not been certified how to solve
- The color is easy to distinguish. General yellow on behalf of the video line, red white plug left and right audio.
- Q: Wire and cable model ZD what does it mean
- The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
- Q: How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
1. Manufacturer Overview
Location | Anhui, China |
Year Established | 1998 |
Annual Output Value | USD516,971,041 |
Main Markets | Southeast Asia; Mid East; Domestic Market; |
Company Certifications | ISO9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | shanghai |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 160,000 square meters |
No. of Production Lines | Above 20 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
Cable Conductor HS156
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5mt m.t.
- Supply Capability:
- 40000mts/year m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches