• Aluminum Foil Composited Bubble Material FBBF1001 System 1
  • Aluminum Foil Composited Bubble Material FBBF1001 System 2
  • Aluminum Foil Composited Bubble Material FBBF1001 System 3
  • Aluminum Foil Composited Bubble Material FBBF1001 System 4
  • Aluminum Foil Composited Bubble Material FBBF1001 System 5
  • Aluminum Foil Composited Bubble Material FBBF1001 System 6
Aluminum Foil Composited Bubble Material FBBF1001

Aluminum Foil Composited Bubble Material FBBF1001

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
10000 m²
Supply Capability:
1000000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Aluminum foil and bubble is the better product in the environmental protection, thermal insulation thermal insulation. The outermost PET has good abrasion resistance and high strength tear resistance. The bubble between the aluminum foil not only has a strong moisture, resistance oxygen, sound insulation, drop noise function, aluminum foil bubble also has very good reflective inverse heat, blocking ultraviolet.




Main Features:




Application:



Specification:

 

STRUCTURE

ALUMINUM FOIL/BUBBLE/ALUMINUM FOIL

ALUMINUM FOIL/ BUBBLE/BUBBLE/ALUMINUM FOIL

ALUMINUM FOIL/WOVEN CLOTH/BUBBLE/WOVEN CLOTH/ALUMINUM FOIL

MPET /BUBBLE/MPET

ALUMINUM FOIL/BUBBLE/FOAM/BUBBLE/ALUMINUM FOIL

THICKNESS

1-4mm

8mm

6.5mm

4mm

4mm

WEIGHT

120GSM

240GSM

180GSM

120GSM

445GSM

BUBBLE SIZE

4mm HIGH x 10mm DIAMETER

2mm HIGH x 10mm DIAMETER

4mm HIGH x 20mm DIAMETER

4mm HIGH x 10mm DIAMETER

2mm HIGH x 10mm DIAMETER

FOAM THICKNESS: 3.5MM

WIDTH

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

THERMAL CONDUCTIVITY

0.034w/mo

0.032 w/mo

0.032w/mo

0.034w/mo

5.87m2.k/w

REFLECTIVITY

96-97%

96-97%

96-97%

96-97%

96-97%





Images:

 




FAQ:

We have organized several common questions for our clients,may help you sincerely:

1)How about your company?

A world class manufacturer & supplier of aluminum foil bubble insulation,is one of the large-scale professional investment aluminum foil composite insulation bases in China, consisting of both casting foundry forging and machining factory. Annually more than 100,000 square meters foil insulation are exported to markets in Europe, America and Japan. OEM service available according to customer's requirements.


2)How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test; We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.


3)How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The specific time of receiving is related to the state and position of customers. Commonly 20 to 25 working days can be served.

4)What is the storage condition?

The welded wire mesh should be stored at room temperature and kept from wet and heat source.

 

Q: Should a two story home have insulation under the roof in the big closets ?
Hell yes it should. A lot of contractors skimp on insulation though. Every singe area in your attic under your roof needs fiberglass insulation or you will lose heat and air and your electric bill will be higher. Heat rises and u will lose it fast in the winter if there is just one small spot without it.
Q: Live in Houston, very hot and humid. Looking at adding radiant and additional insulation to roof in house. We have a lot of sun, and AC bills.
I think you'll get more bang for you buck just going with the radiant barrier and having a continuous ridge vent.
Q: Like how does it get put in your roof?I am doing this energy efficient house.Other Questions:What is an Eave?Whats the roof on top of a patio called?What does orientation mean?What are the good things about French doors?
It can be blown in or more often it comes in large bagged bales and you cut and dump in the attic. The eaves are the portion of the roof that overhangs/extends past the wall. It's usually called a patio cover Orientation is how the home (or other structure) is positioned on the lot. They let in lots of light and are very attractive.
Q: p/t deck on a commercial rubber roof do we need closed cell insulation under deck to protect rubber?
Membrane roofs should not have any sharp edges putting pressure on it. Even a flat square board will sink into the material and the edges are where the problem begins. We put layers of thick tar pads 3/4" under the feet of the air handlers years ago and still no problem.
Q: Would it be worth forwarding the offer to the client? Is the difference that substantial?
You don't want that. If he offers 3.5 instead of the required 3, that is a different story. Otherwise he should give you more material thickness to provide an equivalent R of 3. Yes, the difference can be substantial and I wouldn't forward it to the client. The smaller the R value of the entire roof sandwich the larger the difference it makes. Like the change from 5 mpg to 4 mpg is a 25% worsening in fuel economy, but a change from 100 mpg to 99 mpg is 1%. It will mess up the heating/cooling of the building and the mechanical systems might be inadequate. They could save money on the roof and complain how the building is too hot/too cold or the mechanical systems never shut off and their energy bills are too high.
Q: roof was replaced eight years ago soon after there were leaks in the roof caused insulation toget wet then dry now the insulation is packed hard and has started to turn into power who would be responsible to replace the insulation.
House Owner, Land Lord. If you are the house owner, contact the people who did the work on your roof, find out what your warranty is.
Q: I gutted the room and now would like to rebuild. One side of the room slants (it's the roof) and the other side of the room is a dormer (all low ceilings).I want to insulate the ceiling but have no ridge vents so no moving air as someone mentioned I should have. I want to install foam channels to keep the insulation away from the roof but not sure if this is a good idea without the ridge vents. I will have a vent to the outside installed on the very top of the roof however and the small attic space is open all the way through the other two upstairs rooms and I will add another roof vent on that end of the house. I will only be able to install 3 inch insulation but that's better than none at all. I live in the northeast and was told if the job isn't done right I can get ice jams in winter. Also I don't see any way to drill ridge vents. would it be ok to just install the styrofoam channels and insulate then sheet rock or am I asking for trouble? Thanks in advance for any help.
Suggestion: install the insulation with the foam channels but leave the center section (roof ridge area) open from end to end. At each end you can install a static vent or an active one. Depending on the amount of space you have you may be able to install a power vent.If you can send me a diagram with measurements I can give you a more definitive answer.
Q: Can you put fiberglass insulation on the under side of roof tiles in the loft in the house?
You should not be able to see your roof tiles from inside your house. So no, it can not be done. You can attach insulation to the rafters if that is what you meant.
Q: I have read in some articles about roofing that it is recommended to use attic roof insulation in ones roofing. Is this true?
here in the uk not only is it necessary ..its the law ..under building control up to 250mm 10" of fibreglass is needed ...it keeps house warm in winter and cool in summer
Q: fixing my room up and it gets hot in summer so i want to put some good insulation in the roof so what could i use?
If okorder / what they are finding, along with shingle manufacturers is the spray insulation is not allowing enough air movement in the attic to cool the shingles on the exterior of the house and the shingles are literally baking themselves on the roof! Now, if your room is not the attic and you are simply looking to add insulation to cut energy costs and change the temperature of the living space of your home- I would definitely go with the batten style (or roll) insulation- its an easy install, inexpensive and works really well.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords