Aluminum Foil Bubble Heat Insulation

Description of Aluminum Foil Bubble:

 

Aluminum foil and bubble is the better product in the environmental protection, thermal insulation thermal insulation. The outermost PET has good abrasion resistance and high strength tear resistance. The bubble between the aluminum foil not only has a strong moisture, resistance oxygen, sound insulation, drop noise function, aluminum foil bubble also has very good reflective inverse heat, blocking ultraviolet.

 

Features of Aluminum Foil Bubble:

 

It is the high quality heat insulating and the invincible opponent of anti- condensation. The low and stable coefficient of heat conduction has good isolation effect.

The product has many advantages, such as light weight, heat insulation, shock absorption, sound absorption and noise reduction;

The product is easy to install and process and it also waterproof, seepage control, flame retardant.

The product also has many features, such as heat resistance, low temperature resistance, chemical resistance, ageing resistance etc.

 

Application of Aluminum Foil Bubble:

 

Building reflective heat, cold and hot water pipe insulation;

Refrigerator partition, central air conditioning, refrigerator and household appliances insulation;

Insulation, sound-absorbing, noise reduction and moisture-proof insulation in the car, train, refrigerator car, laboratory and other industries;

Special product packaging and refrigerated packing and so on.

 

Pictures of Aluminum Foil Bubble

 

 

 

Specification of Aluminum Foil Bubble

 

STRUCTURE

ALUMINUM FOIL/BUBBLE/ALUMINUM FOIL

ALUMINUM FOIL/ BUBBLE/BUBBLE/ALUMINUM FOIL

ALUMINUM FOIL/WOVEN CLOTH/BUBBLE/WOVEN CLOTH/ALUMINUM FOIL

MPET /BUBBLE/MPET

ALUMINUM FOIL/BUBBLE/FOAM/BUBBLE/ALUMINUM FOIL

THICKNESS

1-4mm

8mm

6.5mm

4mm

4mm

WEIGHT

120GSM

240GSM

180GSM

120GSM

445GSM

BUBBLE SIZE

4mm HIGH x 10mm DIAMETER

2mm HIGH x 10mm DIAMETER

4mm HIGH x 20mm DIAMETER

4mm HIGH x 10mm DIAMETER

2mm HIGH x 10mm DIAMETER

FOAM THICKNESS: 3.5MM

WIDTH

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

1.2m (MAX 1.5m)

THERMAL CONDUCTIVITY

0.034w/mo

0.032 w/mo

0.032w/mo

0.034w/mo

5.87m2.k/w

REFLECTIVITY

96-97%

96-97%

96-97%

96-97%

96-97%

 

FAQ

We have organized several common questions for our clientsmay help you sincerely:

①How about your company?

A world class manufacturer & supplier of aluminum foil bubble insulationis one of the large-scale professional investment aluminum foil composite insulation bases in China, consisting of both casting foundry forging and machining factory. Annually more than 100,000 square meters foil insulation are exported to markets in Europe, America and Japan. OEM service available according to customer’s requirements.

②How to guarantee the quality of the products?

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality test; We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The specific time of receiving is related to the state and position of customers. Commonly 20 to 25 working days can be served.

What is the storage condition?

The welded wire mesh should be stored at room temperature and kept from wet and heat source.

Q: No insulation was installed under roof of my 2 story home. Im not rich but looking for info on installing about 450 ft. up there.
If there is no existing insulation you need a vapor barrier 1st or you need "faced" fiberglass, the one with either plastic or brown paper on it. I put it as thick as you can afford.
Q: hi me and my friends made a lounge out of my old tin roof shed we have a tv speakers and a few other electrical goods... since winters on its way we were wondering whats the best and cheapest way to insulate the place note that its a tin rof but has wood under it where the old indulation used to be the place is pretty chilly and sometime damp plz help we dont wanna be freezing our asses off in there thanks :)
I would look at using the pink insulation if it will fit between the tin roof and the under it, If not, you may have to remove the wood to install the insulation.
Q: I'm thinking of converting my brick walled corrugated iron shed into a changing room for winter hot tub use. I was advised by a friend that the first thing i should do is insulate the roof using glass fibre insulation (the yellow fluffy stuff in the loft) and a simple Plywood ceiling but im not sure how i would stick it to the existing roof (dimensions 170cm x 147cm). So..... how should i insulate the roof of my future changing room????
If the roof has joists, which I imagine it would, you would put the bats of insulation into those spaces... these can then be stapled into place or if that isn't possible, you can run a wire between the joists to hold the bats in place. If using faced insulation be sure to put the paper side towards the warm area (inside) to prevent condensation.
Q: this room has an aluminum roof and hardwood siding. All the heat hit the aluminum roof
With Reynolds wrap.
Q: what effect does changing the pitch of a roof have on the insulation properties and durability of a roof?
The pitch of a roof has zero effect on the r-rating of insulation. Proper ventilation of the attic space, whether steep or low pitched, simply provides the optimum environment for the r-factor of the insulation to do its job more efficiently. Any attic, regardless of pitch, if it is not properly ventilated, would stress the effectiveness of any insulation product unnecessarily. The durability of the roof is not adversely affected either.
Q: In a house, it looks like an addition, that now is the kitchen , it feels HOT, it doesn't seem to have a very good insulation on the roof at all, the ceiling is already low, so, what can be done on the outside to give it more insulation?, i don't care what it is i just want to give it a GOOD insulation, the roof is flat and to shingles. Any IDEAS? , thanks!
Sorry but there isn't enough info to give a good answer...is there space between the ceiling and the roof to add insulation...there may be enough insulation but no ventilation in the area directly under the roof (atic area) If there is not enough air flow in this area the temperature will skyrocket thus heat the kitchen AND the shingles will deteriorate very quickly.If you still need to add insulation the best way is to put sloped roof (if possible)and add insulation in the space created or you can use foam insulation and re roof ..make sure you seal between the wall system and new insulation and whatever method make sure to allow air to flow under the roof (both inflow and outflow)
Q: if you had snow and all the snow is off your roof and the house nex store has snow do we need insulation?
That is very observant of you. Yes this could indicate that you are losing more heat than normal through your roof. Though, you do want to be careful in the placement of any new insulation, you will want to avoid any vents that are there for ventilation of heat and moisture in the summer and any recessed lighting fixtures as to not cause an overheating problem with them. This is a good investment and it will pay you back in heating and cooling cost for years to come.
Q: Hi, my building is hot in temperature in summers, so I am finding ways to tackle the problem by placing some heat insulating materials against the sunlight on the roof of my building. I have found several possible solutions, but none of them close to perfect. 1. grass layer: hard to maintain2. heat-insulating brick: might be too heavy to carry them to the roof3. heat-insulating coating: would it be damaged if we step on them? Are there things like heat-insulating carpets that would be convenient to instal?
If you're redoing the roof, a radiant barrier under the sheathing helps. So does insulation. And also, if there is an attic space there, consider putting in a fan to blow the hot air out.
Q: weather stripping/ foam strip?
Those foam strips they sell you to go under the ridge caps will eventually dry out, blow out, and be hanging all over the place. Caulking won't fill a 5/8's gap to keep the wind/rain out, and tar has no place whatsoever on a metal roof, you'll get it all over everything, and either one will look like ****. The best ridge cap has to be custom made and cut to fit. I use a 12" wide X 10' strip, bent in half to pitch, and then turn down 90 degrees on the edges, whatever the rib height is, usually 5/8". Hold the ridge cap in place on the ridge and mark where the ribs are, then notch out for the ribs so that the cap sits flush over the ribs and down on the flats, punch holes and screw down thru the tops of the ribs. It's a little time consuming but it makes for a good looking finished product that won't wear out.
Q: A roofer who wants to put a new roof on my mobile home says it will dry out. (We live in the rainiest part of the US)
I think everyone is misunderstanding your question. I think what you are saying is that your insulation got wet, becasue of your roof leaking. The roofer wants to replace the roof but not the insulation. If your talking about an insulation board under the roof then I think your roofer is right. Just put a new roof on. If you talking about some kind of fiberglass batt insulation then it probably should be replaced.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords