What are the working principles of the electric gate valve?
You see what type of electric valve, is integral or ordinary type, if the overall type Denso took power on the line, is generally 380V and 220V power supply, and then according to their own needs and then open the signal line, in place and closing in place and remote control line, valve position feedback signal 4~20ma over torque protection, fault signal. Ordinary type electric valve should be equipped with the control box, the motor is the true story and the inversion, and in general to a trip signal signal is normally open and normally closed, closed in place are normally open and normally closed two points according to their own needs wiring, three lines and then open and close control of the line of control there are also 4 lines to control some manufacturers, as well as the valve position, some three lines connected with the potentiometer, some installed valve position transmitter is connected with two lines, and over torque protection fault signal.
Gate valve z41t what does that mean?
According to the provisions of the JB/T 308-2004 valve type programming method:Z = gate valve4 = connection form: flangeT = sealing surface material: copper alloy
Fire protection gate valve from the wall how many distance there is no regulation?
1 meters away from the wall, leaving the maintenance and replacement distance
Does the tap belong to a stop valve or a gate valve?
Most faucets are stop valves,Part of the faucet is plug valve,Hot water nozzles are almost all plug valves.
Yes, soft sealing gate valve can reach 25 kilograms, Fujian light valve company has this type of soft sealing gate valveAnonymous browsing | 28 times
Soft seal butterfly valve seal is good, but can only withstand up to 16 pressure, or the plastic can not stand. A short period of time is OK, and it's also related to the workmanship and quality of the factory. The quality is poor.
Gate valve Z41H-16Q generally used for what place?
It is a standard flanged gate valve with engineering pressure 1.6MPa. Generally used in chemical processes, of course, can also be used for municipal and civil engineering. The valve is generally used for cutting occasions fully open or fully closed, is not suitable for flow regulation.
What's the difference between the knife gate valve and the stop valve?
Generally large and nominal caliber DN50 mostly with gate valve, especially industrial high temperature, high pressure, highly toxic and so on.Stop valve is able to stop and adjust flow, small footprint, small size, generally less than the nominal diameter, DN50 occasions use it. Two can be closed, in the flow of linear requirements are not high, you can adjust the flow. Just because of its structural characteristics of the valve to make its flow resistance, so there is a demand for throttling with a little more than the gate valve. In addition, the cut-off valve, whether it is a formal or reverse installed, in the opening and closing process, there is always a very difficult, and therefore can not do a great deal, or it is not easy to open and close. In addition, the cut-off valve has a one-way sealing effect of good features, so in the prevention of reverse flow of the working fluid, it also has a place to play.Hope to be of some help to you!
What is the size and length of the DN80 gate valve? 10 kg and 16 kg, respectively?
Valve structure length standards are PN16, short series for 203mm, long series for 280mm, flange size by PN16.