1. Production Introduction
WZB self-priming pump is divided into single phase and three-phase asynchronous types with built-in protection device. The pump is divided into centrifugal impeller and worm casing structures with self-priming function. Single-face mechanic sealing is mounted between pump and motor."0" shaped oil-proof rubber seating ring is used at each stationary port as static sealing.

2. Application
This series pump is a new type of ideal economical pump, widely used in pumping water, increasing water pressure, garden irrigation, water supply for vegetable green houses, industrial mining enterprises and aquatic breeding fields etc.

3. Work Conditions
The pump can work properly and continuously under following operational conditions:
1.Medium is not corrosive.Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40°C and PH should be 6.5-8.5.
3.Power frequency should be 50Hz,single phase voltage 220V, three-phase voltage 380V,and voltage fluctuation should be 0.9-1.1 times than the rated.

4. FAQ

1. Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2. Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3. Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.

4. With regarding the submersible pumps, we can just get a pump head?

It would be acceptable to arrange the pump head alone. All connections are conforming with the international standard. But it is also very necessary to have a confirmation before the delivery, because there are some models which is special.

5. Do you have smaller solar pump?

Yes, we have. Except the solar submersible pump, we also have some surface solar pump, the voltage about it is 12V or 24V. The materials about them are plastic.

6. Can you customize the pump when we needed?

 This is acceptable. But we have to charge some fees in advance, because we need to make the new moulds for it sometimes.



ZB Series Self-Priming Centrifugal Pumps with Good Quality

ZB Series Self-Priming Centrifugal Pumps with Good Quality


Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
When the temperature reaches a certain value, the signal is transmitted to the electric control box through a dry running protector, and the electric control box is used to stop the screw pump so as to protect the screw pump.
Q: What are the functions of a disposable infusion pump?
With the development of science and technology, more and more fields need to control the flow or velocity of fluid accurately. For example, the detection and analysis of micro chemical elements in chemical industry always need to control the flow accurately. In the field of health care, the flow and velocity of traditional Chinese medicine liquid must be controlled accurately.Venous transfusion is one of the most commonly used methods of clinical treatment. It is a common medication and treatment technique for nursing specialty. Clinically, appropriate infusion rate should be applied according to the drug and patient's condition. Transfusion too fast may cause poisoning, more serious can lead to edema and heart failure;
Q: What is the lift of diaphragm pump?
Tell you: diaphragm pump head is liquid through the pump energy obtained is called lift it, and flow and pump speed, a liquid density is generally 1 kg is 10 meters lift, horizontal pipeline 10 meters 1 meters lift, a 90 degree bend is 1 meters.
Q: What are the starting and stopping procedures for centrifugal pumps?
Before using the centrifugal pump, the operation instructions of the centrifugal pump shall be read carefully and the specific operation procedures shall be understood so as to make proper use of the centrifugal pump products. The first step is the operation of centrifugal pump inlet valve of centrifugal pump centrifugal pump for all open cavity filled with liquid, close the outlet valve, start the motor, the motor speed is normal, can gradually open the outlet valve, to adjust to the desired condition. Pay attention to self suction centrifugal pump starts to open the exhaust valve, outlet valve should be opened quickly in the normal operation of the motor, to prevent air inlet pipe off caused by cavitation phenomenon produces centrifugal pump, centrifugal pump vibration phenomenon leads to noise of the smoke is not on the water.
Q: What does "efficiency" mean in a water pump catalog?
General pump efficiency is 60% ~ 85%. high efficiency of the pump, indicating the same work, the pump consumes the lowest energy, and vice versa
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(three) infusion limited number of pills produced after the dose of obstruction by infusion pump and specification of the matching test, will reach acceptable when the storage pressure of the pressure to determine the alarm blocking. Thus, some have restrictions on the infusion tube blocked after the maximum dose pill may have blocked the trigger before the alarm.
Q: What are the main performance parameters of the pump?
The amount of liquid supplied by a pump in unit time. Volume flow Q, unit m3 / s. There is mass flow G, unit is kg / s.
Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
There should be the following reasons: 1) the setting value of the trip switch is too small, and the operating current of the submersible pump exceeds its setting value, and the switch is tripped