• valve of china 2900 System 1
  • valve of china 2900 System 2
  • valve of china 2900 System 3
valve of china 2900

valve of china 2900

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing





Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure

Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature

Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)

Model Number:  GF4 resilient gate valves:  resilient seat flange


Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside

Delivery Detail: 15-60days


SpecificationsDIN3352 F4 resilient seat flange gate valves

1.size:DN40-DN300

2.medium:water

3.standard:DIN

4.certificate:ISO9001 CE


resilient gate valves

1.size:DN40-DN300

2.medium:water

3.certificate:ISO9001 CE

4.standard:DIN


available medium:water

working temperature:≤80oC


flange dimensions:DIN2501


face to face dimensions:DIN3202F4.


Q: Why use special flanges for butterfly valves?
Mainly for clip type butterfly valve sealing ring on the valve body than the ordinary flange chip small diameter. Therefore, the ordinary flange can not guarantee the effective sealing effect. Therefore, you must use a dedicated butterfly flange sheet
Q: 1st where is my zone valve? I have an old Burnham gas baseboard heater2nd What do I do?My last resort is calling a proffesional.
First: Wat make you tinkling that the zone is bad? Every zone cooperate with 2 other essential parts: thermostat and power supply, In 90% of my carea, people firs go with their thinking to zone, but only 10% was realy zone. The first thing to check is termostat and power. you could do this very simply by removing termostat wire and tickling them together several times, if they have spark, than the most prabably is just thermostat broken
Q: How can I get the fire signal butterfly valve?
1, the signal butterfly drive by the worm gear drive shaft and butterfly plate rotation, realize the opening and closing and control flow. 2, rotating the handwheel worm gear to the disc to open and close and adjust the flow to the handwheel clockwise rotation for the valve closed. 3, worm gear is arranged in the box body micro switch has two forms: A, in the gear box body is provided with open and close direction two microswitches, respectively, when the valve fully open and close action, connected to the control room "valve open" valve off "light source, the quasi it shows the state of the valve switch. B, in the driving device is arranged in the box body the microswitch (disc position close to 0 degrees), when the butterfly plate from 0 degrees to 40 degrees when the position of a micro switch, the output valve closed signal, 40 degrees to 90 degrees when the position of another pair of normally closed output valve opening signal. A cam that adjusts the touch microswitch and shows the different positions of the disc.
Q: Have an iron block, aluminum heads, solid roller lifters, Jessel rocker shafts, what should my valve clearances be cold, and hot??
Your cam dictates the valve lash. What cam is in this engine? Contact the cam company. Most have on-line tec support or a 1-800 customer service department.
Q: Specifically an engine valve retainer.
Valve Retainer
Q: Gate valve, butterfly valve and so on can do the valve so that?
Yes, but the accuracy of the adjustment is not high. Just about. To adjust the flow, please use flow control valve.
Q: Who can give me a download UG butterfly valve, needle valve, diaphragm valve standard model address, Japanese standard, American Standard.
Support many 3D CAD format, such as the commonly used UG, Pro/E, SolidWorks......As for the butterfly you said, don't post the link up, the standard JIS, American Standard ANSI, German standard DIN are.You use Baidu Search "LinkAble PARTcommunity", after the open registration, CAD format, such as UG, ASAHI and then to find the manufacturer home page, which is the valve, you said the Japanese standard, German standard, American Standard valve basically all.
Q: What's the difference between butterfly valves and check valves?
Butterfly valve is manual, only switch function.The check valve is an automatic valve, which prevents backflow of the pipe medium.
Q: How to connect the signal butterfly valve?
If you mean the signal of fire water supply system, there are generally three outlets, one public, one open and one off. Fire control system signal butterfly valve is normally open, so the signal butterfly valve to open position, with a multimeter to measure the 2 lines, the 2 lines into the input module is fine.
Q: Butterfly valve structure and working principle
The clip type butterfly valve is connected with the two pipe flange with a stud bolt. The flange type butterfly valve is provided with a flange on the valve, and bolts are used to connect the flanges at the ends of the valve to the pipe flange.