Switch Power Supply 24V 600 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification:
Model | HS-600-12 | HS-600-13.5 | HS-600-15 | HS-600-24 | HS-600-27 | HS-600-48 |
Specification |
|
|
|
|
|
|
DC output voltage | 12V | 13.5V | 15V | 24V | 27V | 48V |
Output voltage tolerance(Note:2) | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 50A | 44.5A | 40A | 25A | 22A | 12.5A |
Output current rage | 0-50A | 0-44.5A | 0-40A | 0-25A | 0-22A | 0-12.5A |
Wave and noise(Note :3) | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p |
Inlet stability(Note :4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity (Note :5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 80% | 80% | 82% | 82% | 82% | 84% |
AC input voltage range | 180-264VAC 47-63Hz;254-370VDC | |||||
6.5A/230V | ||||||
50A/230V | ||||||
<3.5mA/240VAC | ||||||
105%~135% hiccup mode, auto recovery | ||||||
115%-135% cut off the output, auto recovery | ||||||
ERH3>=65°C~70°C Fan on,<=55°c~60°cfan>=80°C~85°C,Cut off output(5~15V)Cut off output(5~15)~(24~48V) | ||||||
±0.03%/°C(0~50%) | ||||||
200ms,100ms,20ms | ||||||
10~500Hz,2G 10min,/1cycle,Period for 60min,each axes | ||||||
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | ||||||
Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | ||||||
-10°C~+60°C(Refer to output derating curve),20%~90%RH | ||||||
-20°C~+85°C,10%~95%RH | ||||||
238×124×65mm | ||||||
1.5Kgs, 12pc/CTN | ||||||
- Q: What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
- Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
- Q: Why should lighting transformers be used in factories and mines?
- But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q: Why is elevator lighting transformer installed?
- 1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
- Q: How is the lighting power of the 380V transformer calculated?
- Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
- Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
- Q: Power and lighting transformers, lighting quality will be affected much?
- Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
1. Manufacturer Overview
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Switch Power Supply 24V 600 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords