• Switch Power Supply 24V 600 Watt System 1
Switch Power Supply 24V 600 Watt

Switch Power Supply 24V 600 Watt

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
10 Pieces pc
Supply Capability:
10,000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Specification:

 

Model

HS-600-12

HS-600-13.5

HS-600-15

HS-600-24

HS-600-27

HS-600-48

Specification

 

 

 

 

 

 

DC output voltage

12V

13.5V

15V

24V

27V

48V

Output voltage tolerance(Note:2)

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

50A

44.5A

40A

25A

22A

12.5A

Output current rage

0-50A

0-44.5A

0-40A

0-25A

0-22A

0-12.5A

Wave and noise(Note :3)

240mVp-p

240mVp-p

240mVp-p

240mVp-p

240mVp-p

300mVp-p

Inlet stability(Note :4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stablity (Note :5)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Efficiency

80%

80%

82%

82%

82%

84%

AC input voltage range

180-264VAC 47-63Hz;254-370VDC

Input current

6.5A/230V

AC INrush current

50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~135% hiccup mode, auto recovery

Over voltage protection

115%-135% cut off the output, auto recovery

High-temperature protection

ERH3>=65°C~70°C Fan on,<=55°c~60°cfan>=80°C~85°C,Cut off output(5~15V)Cut off output(5~15)~(24~48V)

Temperature coefficient

±0.03%/°C(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ

Working temperature and humidity

-10°C~+60°C(Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95%RH

Overall dimension

238×124×65mm

Weight/Packing

1.5Kgs, 12pc/CTN

Note:

 

1.The testing condition for the parameter above is :230VAC input,rated load,25°C70% RH.Humidity.

2.Tolerance include the setting tolerance,line stability and load stability.(Note:5).

3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.

 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q: Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q: The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
I don't know how much the output voltage of your transformer is, but the internationally accepted voltage below 36V is the voltage that is not harmful to the human body
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
Line lighting transformer is suitable for AC circuit of 50~60 (Hz). It is widely used in electronic industry or industrial and mining enterprises, mechanical equipment, general circuit control power supply, safety lighting and indicator light power supply.
Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
Q: How is the lighting power of the 380V transformer calculated?
The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
Q: How to calculate the rated capacity of small transformers for lighting purposes?
In view of the power [kVA] conversion of each load, multiplied by the amount of consumption, according to the importance of the load, equipment location, voltage statistics, set the load line and load place of plastic case transformer capacity and its connection position. The future load power equipment shall be judged on the basis of prior installation or consideration of the economy in terms of equipment addition, installation, etc..
Our company carries out a strict management mechanism, and spares no effort to establish effective incentives and constrains system; improve corporate structure. Under no circumstance, the company always adheres to the business philosophy all matters, big or small; equal consultation; continuous improvement.

1. Manufacturer Overview

Location Shenzhen, Guangdong, China (Mainland)
Year Established 2011
Annual Output Value US$5 Million - US$10 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia
Company Certifications ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Yantian
Export Percentage 41% - 50%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords