Specification:

 

Model

HS-600-12

HS-600-13.5

HS-600-15

HS-600-24

HS-600-27

HS-600-48

Specification

 

 

 

 

 

 

DC output voltage

12V

13.5V

15V

24V

27V

48V

Output voltage tolerance(Note:2)

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

50A

44.5A

40A

25A

22A

12.5A

Output current rage

0-50A

0-44.5A

0-40A

0-25A

0-22A

0-12.5A

Wave and noise(Note :3)

240mVp-p

240mVp-p

240mVp-p

240mVp-p

240mVp-p

300mVp-p

Inlet stability(Note :4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stablity (Note :5)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Efficiency

80%

80%

82%

82%

82%

84%

AC input voltage range

180-264VAC 47-63Hz;254-370VDC

Input current

6.5A/230V

AC INrush current

50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~135% hiccup mode, auto recovery

Over voltage protection

115%-135% cut off the output, auto recovery

High-temperature protection

ERH3>=65°C~70°C Fan on,<=55°c~60°cfan>=80°C~85°C,Cut off output(5~15V)Cut off output(5~15)~(24~48V)

Temperature coefficient

±0.03%/°C(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ

Working temperature and humidity

-10°C~+60°C(Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95%RH

Overall dimension

238×124×65mm

Weight/Packing

1.5Kgs, 12pc/CTN

Note:

 

1.The testing condition for the parameter above is :230VAC input,rated load,25°C70% RH.Humidity.

2.Tolerance include the setting tolerance,line stability and load stability.(Note:5).

3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.

 

 

Q: What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q: Why should lighting transformers be used in factories and mines?
But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q: Why is the two side of the lighting transformer grounded?
Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
Q: Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q: How is the lighting power of the 380V transformer calculated?
Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q: Power and lighting transformers, lighting quality will be affected much?
Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
Our company carries out a strict management mechanism, and spares no effort to establish effective incentives and constrains system; improve corporate structure. Under no circumstance, the company always adheres to the business philosophy all matters, big or small; equal consultation; continuous improvement.

1. Manufacturer Overview

Location Shenzhen, Guangdong, China (Mainland)
Year Established 2011
Annual Output Value US$5 Million - US$10 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia
Company Certifications ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Yantian
Export Percentage 41% - 50%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords