Resilient seated double eccentric flanged butterfly valve DN40-DN1800

Resilient seated double eccentric flanged butterfly valve DN40-DN1800

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Technical Date:

Size: DN100-DN4000

Nominal Pressure: PN10/PN16

Operation Temperature: -10°C~150°C

Suitable Medium: Water,Sewage,Seawater,Gas,Food,Oils,etc.

2. Standard

Design Standard: GB/T 12238-2008

Structural Length: GB/T 12221-2005

Top Flange dimensions: ISO5211

Face to face dimensions: GB9112,DIN2501,BS4504,ISO2084,ANSI125

Type of connection:Flanged type

3. Features:
This valve is mainly composed of body, disc, stem, seat and transmission equipment. Simple, compact structure, small, portable, convenient transportation, installation and removal. 90 degrees, opening and closing of the switch is rapid, operation is small, light energy, sealed performance is good, service life is long, can achieve zero leakage. Flow curve tending to straight line. Excellent regulation performance.
4. Sealing performance:
Rubber seal valve, close the disc and seat sealing performance is good, and the torque is small. Is small, the friction between the butterfly plate and valve seat seal. Disc of the valve shaft drive, butterfly plate do rotate 90 degrees. Butterfly plate, flexible for opening and closing, without jamming, jumping phenomenon, small torque. Large diameter valve can replace the sealing ring online, convenient maintenance. Reverse valve seal is not good


 

Q: What is the difference between turbine butterfly valve and flanged butterfly valve?
The worm gear is the driving mode and corresponds to the handle; the flange is connected and corresponds to the clamp. Flange worm valve is generally, the handle of the butterfly valve
Q: Why anti condensation of aluminum alloy anti condensation butterfly valve?
Anti condensation butterfly valve principle: the use of the high performance plate material, can effectively prevent the temperature of body parts, isolating the transfer medium in the pipeline, to the actuator and the connecting flange surface without dew.
Q: I want to switch off the water in the bathroom only due to replacing sink taps, will water still come out of the pipe if i turn the stop valve
Only water what is still in the pipes will come out but you will lose all your hot water in the hot water cistern if you have that type of hot water storage tank.
Q: How do you draw the butterfly valve in the engineering drawing?
Butterfly valve there are many kinds of painting, according to the design institute out of the icon, below we together to understand the icon, which has the butterfly drawing.
Q: The flow ratio of area and maximum flow area of the valve is? If it refers to the opening of the valve rotation angle? Butterfly linear closure refers to the butterfly valve at constant angular velocity close? When the change trend of flow is what? These valves problem bothering me for a long time,
Butterfly valve "opening - flow" curve in the flow of 25%-75%, that section is basically linear. That is, the opening of 40%, that flow is about 40%Butterfly valve opening degree of 0.5, should be opened 50%, that is, opening to 45 degrees;
Q: The water supply pipe is the gate valve And on the cross dry pipe are the gate valve? To answer the 30
1, this is a good question, it seems that this has not yet made a unified standard requirements, a bit confused2, personal understanding of fire water supply pipe, pipe shall be installed on the valve, because the valve is fully open all closed features of fire control system is usually required is fully open, easy management features are obvious.3, fire water supply system is also useful to butterfly valve, but mainly signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q: What are the classification criteria for pneumatic butterfly valves?
The channel of the valve body inner surface smooth, fluid resistance, high CV value, strong circulation, moderate torque, the use of four seal structure and elastic rubber gasket seat with SI in high temperature aging on the outside sealing surface, zero leakage medium.Pneumatic butterfly, characteristics, there is a slit leaving the valve seat, the product is suitable for use in poor air circulation environment.The pneumatic telescopic butterfly valve is characterized in that the novel and reasonable design, unique structure, light weight, convenient operation, open and close rapidly; in addition to the telescopic valve for regulating and throttling effect, compensation pipeline temperature generated by thermal expansion and contraction function, but also for the installation of valve replacement and maintenance convenience. The sealing parts can be adjusted, replaced, sealed, reliable and so on.
Q: My quot;check engine soonquot; light came on yesterday and soon after that I took it to the nearest Midas to have the diagnostic test run on it - they stated I needed an ERG valve. I have no clue what it is and was told that it could run $160. - $300. for my 1900 Astro van. what is an ERG valve? I have noticed that my van has a low humming sound when I'm driving it.
EGR stands for exhaust gas recirculation. It recirculates your exhaust gases back into the combustion chamber to lower temperatures and NOx emissions. This valve commonly gets clogged with carbon due to the fact it's recirculating exhaust gases. If the diaphram is not broken or damaged and still works, frequently you can simply remove the EGR valve and have the carbon cleaned out. It's a dirty job, but can be done if you can get to the EGR valve. If you do need to purchase the part it typically runs about $175. Labor charges will depend on where it's located.
Q: What's the difference between electric butterfly valve and electric two way valve?
The electric two way valve is specially used for the fan coil of the central air conditioner. It is usually used in conjunction with the temperature controller. It can realize the automatic regulation of temperature. But the electric butterfly valve and the electric control valve belong to a kind of variety, and they are important execution units in the field of industrial automation control.
Q: Which is better, the round two lobe butterfly valve?
Round type double butterfly butterfly valve is the first choice of Shanghai Machinery & Equipment Co., Ltd., the company is a professional design, manufacture and sale of central air-conditioning products at the end.