• Passenger Elevator System 1
Passenger Elevator

Passenger Elevator

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Unit unit
Supply Capability:
200 Units per Month unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Detailed Product Description

1.German technology VVVF drive

2.Lower noise

3.Steady running

4.Competitive price

5.Etching decoration inside

Products name Model Speed(m/s)                 Rated load (kg)
   Passenger elevator WP20      2.00 ------ ------ 800 1000 1250 ------
     1.75 ------  630 800 1000 1250 ------
     1.60 ------  630 800 1000 1250 ------
     1.00  400  630 800 1000 1250 ------

Small machine room

  Passenger elevator

WP30      2.00 ------ ------ 800 1000 1250 1600
     1.75 ------  630 800 1000 1250 1600
     1.60 ------  630 800 1000 1250 1600
     1.00  400  630 800 1000 1250 1600
     3.00 ------ ------   1000 1250 1600
     2.50 ------ ------ 800 1000 1250 1600

Machine room less

Passenger elevator

WPN30      1.75 ------  630 800 1000 1250 1600
     1.60 ------  630 800 1000 1250 1600
Q: Elevator in the first floor has set fire switch, and fire linkage What is the difference? More
Function the same, control the location of different elevators, fire linkage is the fire switch extends to the abduction center, and feedback to the first floor after the elevator to open the door signal
Q: How many meters are needed to build a lift?
Residential Design Code clearly states: 4.1.6 seven or more residential or household entrance floor floor from the outdoor design of the ground height of more than 16m residential must be set up elevator. Note: ① the bottom of the store or other space as a multi-storey residential, the entrance floor of the building from the building's outdoor design of the ground height of more than 16m must be set up the elevator; ② the bottom of the floor or storage space of multi-storey residential, The entrance floor of the household entrance from the building outside the ground height of more than 16m must be set up the elevator; ③ the top floor of a set of two layers of thermocline residential, the thermocline part of the number of layers. The height of the building floor of the building is not more than 16m, the elevator can not be the elevator; ④ the middle layer of the building has the entrance to the outdoor ground and has a fire channel, the number of layers can be calculated from the middle layer ; In addition, "Office Building Design Code" also provides: 4.1.3 five and five floors above the office building should be set up elevator.
Q: What is the meaning of the upper limit of the ceiling?
To prevent the elevator out of control, in the end also put the wire, or to the top of the winding wire, or to the door that the reaction was slow, the elevator stopped in the middle of the floor, are limiter tube limit switch can be divided into upper and lower limits, Simply put on the stop switch and stop the switch. General limit and slowdown switch, limit switch installed together, from high to down in order, the upper limit - upper limit - on the strong reduction. The elevator pit and the top floor of the other group. When the elevator to run to the top of the time (from bottom to top), if the speed is very fast, will first encounter on the strong reduction, that is forced to slow down, the elevator began to slow down, and then hit the upper limit, this time the elevator should stop, Fast, it will encounter the last safety switch, the limit, this time the elevator safety circuit open, the elevator in the shock state, there will be crowded, if the speed soon soon, continue upward, this time the governor action, security Clamp the guide rails. The elevator stops.
Q: Raise the height of 110 meters, do the machine room elevator feasible?
Can be, to see the specific situation
Q: How to measure the safety dimensions of the elevator
Bottom pit should have a 0.5m × 0.6m × 1.0m space. The distance between the bottom pit and the guide shoe, the safety gear and the door part is not less than 0.1m, and the distance between the other parts of the car is not less than 0.5m. The key to the actual impact of the depth of the pit is: (1) the distance that the bumper is fully compressed from the bottom of the car to the bottom of the hoistway; (2) when the end is flat, the car extends into the bottom pit The height of the buffer and the sum of the three. It is not difficult to find that the two together define the depth of the pit in a range that is difficult to substantially shrink: if the height of the buffer is excessively reduced, it is difficult to satisfy the previous condition; if the empty range is excessively reduced, The latter condition violates the national standard. If the pit depth exceeds the required size, it may cause the car to go beyond the national standard allowable value. In the case of not much, you can increase the buffer by the way to solve the base; if too much, only back to the bottom of the pit to the required depth.
Q: There is no exhaust fan in the elevator
No, there is a corresponding exhaust. There is no dedicated exhaust fan.
Q: Do you want to be next to the elevator? What is the role?
That the wind shaft is the fire elevator front chamber pressure air supply, according to the specification must be. Role: the fire before the room to send air, to maintain the pressure in the former room is slightly higher than the other areas, Fu Ding Dian Gu? The two pairs of lost crystal smoke will not go to the front room and the adjacent stairs came ( Take the ladder also have this set of things). Fire elevator front room is the key setting for evacuation and escape. Which must also have a fire hydrant, is to firemen to suppress the fire when the fire open road.
Q: How to save the elevator
I am engaged in maintenance, you say this situation is very rare, very little, do not know? There is a possibility, that is overload, so advise you not to squeeze the elevator. Normally the elevator will not fall. Even if it is overloaded fall, nor is you imagine the free fall, as the speed will not be very fast. The elevator has a lot of protection devices, even if the same protection device failure, can not fail at the same time, so the elevator is safe, the elevator for more than 100 years, you heard someone in the elevator from falling above the fall of the people? No. The elevator has to kill people, but are not falling when people died in the elevator, dead mostly elevator workers. Belong to the illegal operation, their own play dead. So the elevator failure, do not panic, stay inside do not tamper on the line, no life dangerous. As for the TV on the knees to bend like, no need. Right is immediately by the elevator phone keys, notify the professionals to deal with. Do not arbitrarily Pa door, tamper with the like. If the phone is unreasonable, mobile phone, mobile phone nowhere, pat on the car door, propaganda. Hope to adopt. Thank you
Q: Assassin's Creed 4 The first off the elevator on how
Into the elevator, aiming at the logo like wifi by E
Q: Vertical elevators between the two kamels distance 11m must be installed in the middle of the security door?
Yes, according to the provisions of (1) when the adjacent two-door gate of the gap between the big tiger gong port harboring locust song Wei linked to 11m, during which should be set to a height of not less than 1.80m, width of not less than 0.35m of the well safety door (3) the door should be installed with a key to open the lock, when the door is open without a key to be able to close and lock, after the door locked (after the door is locked) , The key can be opened from the hoistway; (4) the electrical safety device should be provided to verify the door closed
Our elevator control system comes from Germany technology, it is very precise and efficient but operation is simple, it can be mastered by engineers easily. Our purpose is: Make qualified and safe elevator products for people. Up to Dec.1, 2012, we have exported more than 1000units elevators and 800units escalators to more than 30 countries markets. Most of elevators and escalators which had been installed are running very well.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords