Panoramic Elevator (Crcle Type)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Unit unit
- Supply Capability:
- 200 Units per Month unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Detailed Product Description
1.German technology Advanced VVVF drive
2.Lower noise
3.Steady running
4.Competitive price
5.Good for sightseeing
Product name | Model | Speed (m/s) | Rated load (kg) | ||||
Panoramic elevator | WO20 | 2.00 | ---- | ---- | 800 | 1000 | ---- |
1.75 | ---- | 630 | 800 | 1000 | ---- | ||
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- | ||
Small machine room Panoramic elevator |
WO30 | 2.00 | ---- | ---- | 800 | 1000 | ---- |
1.75 | ---- | 630 | 800 | 1000 | ---- | ||
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- | ||
Machine room less Panoramic elevator |
WON30 | 1.75 | ---- | 630 | 800 | 1000 | ---- |
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- |
- Q: What is the relationship between load bearing and area of elevator? Please know my friend tell me, thank you! More
- GB GB8888-2003 in paragraph 8.2.1 has a table 800kg, 173 ~ 2.kg, 2.15 ~ 2.kg, 3.25 ~ 3.56
- Q: How does the elevator GB balance factor determine? What is the basis for determining?
- In the no-load and full load between the one to achieve power, reduce the purpose of traction machine
- Q: Our company is equipped with seven passenger and cargo elevator, is the door to the door, there are modern Korean THJ3000 / 0.75 and THJ3000 / Tam Square, both the eternal tea compensated leaching; 0.25 two models are mainly used for cargo. There is a certified elevator driver to operate, but because the staff to streamline the elevator driver resigned in the elevator to install the camera. The company has a elevator safety management, certified. Will this situation can not operate the elevator driver? Which elevator must To be equipped with the driver? The best relevant laws and regulations can explain, because the company has engaged in ISO environmental management system, special equipment requirements. Thank you! More
- The signal-controlled elevator requires the driver to operate the set of controls that are not needed
- Q: What are the requirements of the fire function of the elevator?
- Fire elevator set requirements, there is a complete set of norms. Very detailed, very fine to the. Simply to you to talk about: just upstairs also said the point; have a dedicated button; top should not be greater than one minute; before the room to the outdoor shall not be greater than 30 meters, planting weight shall not be less than 800kg. These are just the most basic features. Its detailed settings, as well as the specific norms, there is a very complete to save. Such as the front room fire rating, the former room position, the front room area, smoke and smoke, the front room of the door, retaining facilities, ladder and car fire design requirements, electrical system, Leopard Mo fire design requirements. and many more. se are not a word or two can be clear, specifically you have to refer to the specification. Specification is not what one person said, is the fire law set, only in line with the norms to pass the acceptance.
- Q: 1. Analysis of the reasons for the breakage of the elevator wire rope 2 Is the steel wire rope broken and the rest should be replaced at the same time? Where is the standard downloaded? More
- There are two cases of wire rope section: 1, the quality of wire rope is not good; 2, up the wheel of the force there is a problem, the state is not allowed to 5%, if the force is greater, may lead to damage to the traction wheel. Wire rope in general if there is a phenomenon of shares have to be replaced. These standards you can find in the State Quality and Technical Supervision where it is, where more complete it...
- Q: Who can talk about the details of the use of contactors on the elevator, I have come into contact with some of the circuit can see a little bit to understand, but in fact to Mongolia, who can elaborate on what, the best example, such as Some of the contacts of the contactor, interlock, the purpose is to see the intestinal 礌 spotting alone do sweepers of the contactor I can understand which line is the coil, which line is the main contact, which is Interlocking, and some other what, depressed do not know even asked do not know how to ask, who can elaborate under the big brother. More
- This is not a good way to say. Specifically you can look at your circuit diagram, combined with the actual circuit. In addition, the label on the circuit diagram corresponds to the label of the component in the actual circuit. Interlocking point as long as the principle and role of interlocking, you can understand
- Q: The above questions are in the civil design code 6.8.1. But do not know what reason. More
- Just to prevent more than 4, the elevator came to see it, because the elevator hall into the deep limited, it may not know the elevator door opened. The The...
- Q: Vertical elevators between the two kamels distance 11m must be installed in the middle of the security door?
- According to the national standard GB7588-2003 requirements: 3.16 hoist safety door emergencydoortothewell when the distance between the adjacent two-level kanyets more than 11m, opened in the middle of the roadway to the wells for the rescue of passengers with the door. There are two basic practices: 1, is the establishment of security doors; 2, in the case of some high-end office projects, from a layer directly to the 15 layer, the middle of the elevator are non-stop and can not set the security door, two or more parallel to the case, You can consider the elevator and the elevator between the real tiger harbor harbor fan locust song Wei attack line rescue each other, the elevator car to do special treatment, air bypass can be. This approach is a relatively large brand of mature, foreign use more.
- Q: Conan has a set is the body hidden in the elevator, which is caused by overload ah
- 050 library killings this episode has a little bit of horror, hope can help you!
- Q: Is the elevator not a box? Fall into the hoistway inside I do not understand, I do not even know what the road is ah! The Help out the question added: how people will fall? More
- The elevator is in a building in the lifting device, there must be a channel from the bottom to the installation of the elevator, the channel floating flower first Ying dumpling electric spear spear is vertical, called the elevator shaft, if something fell Of the words, it should fall in the elevator shaft under the
Our elevator control system comes from Germany technology, it is very precise and efficient but operation is simple, it can be mastered by engineers easily. Our purpose is: Make qualified and safe elevator products for people. Up to Dec.1, 2012, we have exported more than 1000units elevators and 800units escalators to more than 30 countries markets. Most of elevators and escalators which had been installed are running very well.
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Panoramic Elevator (Crcle Type)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Unit unit
- Supply Capability:
- 200 Units per Month unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords