• Panoramic Elevator (Crcle Type) System 1
Panoramic Elevator (Crcle Type)

Panoramic Elevator (Crcle Type)

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Unit unit
Supply Capability:
200 Units per Month unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Detailed Product Description

1.German technology Advanced VVVF drive

2.Lower noise

3.Steady running

4.Competitive price

5.Good for sightseeing

      Product name    Model  Speed (m/s)         Rated load (kg)
      Panoramic elevator    WO20        2.00 ---- ---- 800 1000 ----
       1.75 ---- 630 800 1000 ----
       1.60 ---- 630 800 1000 ----
       1.00 ---- 630 800 1000 ----

     Small machine room

      Panoramic elevator

   WO30        2.00 ---- ---- 800 1000 ----
       1.75 ---- 630 800 1000 ----
       1.60 ---- 630 800 1000 ----
       1.00 ---- 630 800 1000 ----

      Machine room less

      Panoramic elevator

  WON30        1.75 ---- 630 800 1000 ----
       1.60 ---- 630 800 1000 ----
       1.00 ---- 630 800 1000 ----
Q: How does the elevator GB balance factor determine? What is the basis for determining?
The balance factor (K) is a familiar and unfamiliar parameter for elevator professionals. It is known because we all know that the traction elevator has a balance of the weight of the configuration, all know that the national standard in the provisions of the balance coefficient should be in the range of 40% to 50%. (1) directly weighing P and W balance coefficient K is not a mysterious parameter. In the final analysis it is to configure the weight of the weight of the weight, so the balance coefficient K is determined by the balance coefficient design value to configure the weight. This method is cumbersome to operate, and the other parts of the weighing is difficult to achieve without omission, generally not applicable. (2) According to the known K value, the weight of the weight is determined from the balance coefficient K. When the load corresponding to KQ / H is loaded in the car, the static moment on both sides of the traction wheel should be balanced. If you know the design value of the balance factor, simply load the load and verify that it is balanced. The easiest way to verify is to release the brake on the mainframe, and use the manpower to feel the torque balance on both sides of the traction wheel on the hand wheel to increase or decrease the weight. (3) According to the existing weight, it is recommended to use the method of measuring the traction motor current on the national standard. The basic principle is: when the elevator for uniform operation, the traction motor shaft output torque converted to the motor shaft, the elevator mechanical transmission resistance resistance torque (referred to as resistance torque)
Q: Our company is equipped with seven passenger and cargo elevator, is the door to the door, there are modern Korean THJ3000 / 0.75 and THJ3000 / Tam Square, both the eternal tea compensated leaching; 0.25 two models are mainly used for cargo. There is a certified elevator driver to operate, but because the staff to streamline the elevator driver resigned in the elevator to install the camera. The company has a elevator safety management, certified. Will this situation can not operate the elevator driver? Which elevator must To be equipped with the driver? The best relevant laws and regulations can explain, because the company has engaged in ISO environmental management system, special equipment requirements. Thank you! More
But there is little need to add is: cargo elevator if the car area exceeds GB7588-2003 "elevator safety technical specifications" requirements, the use of units should be Equipped with driver's license.
Q: What is the elevator called? A word in the smoke alarm. Thank you! Question added: fire switch, moving switch elevator will return to the first floor ... please explain some of the details ok, thank you! Reply: Thank you for the answer 紶 Flower official arrest dumpling rule evil spear, all good! But still do not quite understand that the fire elevator needs this switch, the fire is prohibited to use the elevator ---, do not fire the elevator did not return to the first floor? What else is an election ladder and an optional ladder? Thank you! More
Fire switch, moving switch elevator will return to the first floor. Fire lifts need this switch, the fire is prohibited when using the elevator.
Q: Solve this problem.
In the men pull the knife to the 3rd floor, according to individual buildings
Q: What are the embedded parts in the elevator shaft?
If the shaft of the hoistway is a brick structure, it is necessary to set up a ring beam every 1500mm to 2000mm height in the hoistway (the first gear ring in the bottom of the hoistway is made up of 1500mm Set, from the second gear ring began to set by 2000mm, the top of the hoistway last gear ring by the floor 400mm set), ring beam height ≥ 300mm, elevator floor should be equipped with a beam on the edge, beam height 350mm, beam The width of the same width and the hoistway, and shall not protrude into the hoistway (the beam used to install the floor of the floor door) 2, the basement or other floor structure is not the structure of the floor, Along the beam with a beam height of ≥ 350mm, the length of the beam and the same width of the hoistway, and shall not protrude into the hoistway (this spoiled anger to drink sewn bucket bucket for the installation of the elevator floor gate) If the wall of the hoistway is a fully castable structure, it is not necessary to set the beam and the beam. If the wall of the hoistway is part of the cast - in - place structure, the position of the ring beam and the over - beam must be set.
Q: Will the different elevator manufacturers describe how to force the closure of this function? There is the door is divided into large door sets and small door sets, door sets and small door sets of parameters which? Which heroes Dingzhuang melon melon cover cover sorrowful twins to help me, be grateful! The The More
Different manufacturers of the size of the door is not the same, you can call to ask the specific, you can ask as to force the door to close the function of the spider melon melon cover cover sorrow fine, I only know that a situation is the elevator fire function , From the security layer to open the door after no one in the car automatically forced to close the door and no longer outside the call and call within the emergency operation is usually UPS function
Q: The woman came home and found to be a man tracking ... ... ... ... elevator to the second floor, the man turned out when she smiled ... when the door closed, she suddenly saw the man took out the knife to the third floor ... the results of a woman died. Q: Do not cancel the third floor of the case how can let her survive? More
Can not think of .. woman should be wrong, so that men choose the first two layers .. If a woman does not choose the floor? Then look at a few layers of men .. Oh .... there is a woman selected 3, men See the man ... then the man will certainly go to the third floor waiting for her .. woman should wait for a man out of the elevator .. either choose the next, or continue to choose on .. is not out of the elevator 3 ... Oh .. Do not come out
Q: Do you want to be next to the elevator? What is the role?
That the wind shaft is the fire elevator front chamber pressure air supply, according to the specification must be. Role: the fire before the room to send air, to maintain the pressure in the former room is slightly higher than the other areas, Fu Ding Dian Gu? The two pairs of lost crystal smoke will not go to the front room and the adjacent stairs came ( Take the ladder also have this set of things). Fire elevator front room is the key setting for evacuation and escape. Which must also have a fire hydrant, is to firemen to suppress the fire when the fire open road.
Q: What is the reason why the elevator door is always open and closed when not in use?
Close the door in question.
Q: How much is the elevator operation certificate?
Elevator service card (operation card) posts necessary, the quality supervision issued by the elevator operator to run the elevator maintenance and operation of the elevator installation and installation of elevator drivers, maintenance, installation examination evidence collection group more favorable, more than 30 people can be in the training. Electric performance burning bite to eat the feast to find the way to find the driver 400 yuan elevator operation and maintenance 400 yuan elevator running to install 400 yuan
Our elevator control system comes from Germany technology, it is very precise and efficient but operation is simple, it can be mastered by engineers easily. Our purpose is: Make qualified and safe elevator products for people. Up to Dec.1, 2012, we have exported more than 1000units elevators and 800units escalators to more than 30 countries markets. Most of elevators and escalators which had been installed are running very well.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords