Freight Elevator VVVF
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Set set
- Supply Capability:
- 1000 Sets per Month set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Detailed Product Description
Special control system,
effective and reliable drive mode,
sensitive and flexible VVVF variable frequency door machine.
Standard Function
Travel function
Group selection control |
Group selection controlling without the presence of operator |
Reopen with hall call |
In the door shutting process, press reopen with hall call button can restart the door. |
Car stops and door open |
The lift decelerates and levels, the door only opens after the lift comes to a complete stop. |
Automatic returning to the base station |
When the traffic flow is low, lift without receiving commanding signals will automatically return to the base floor and standby with the door closed. |
Directly running |
Under the operator's control, after the direct running button is pressed, the lift only runs directly according to the directives from inside the car and does not respond to any calls from outside. |
Automatic pass without stop |
When the car is crowded with the passengers or the load is close to preset value, the car will automatically pass the calling landing in order to keep maximum travel efficiency. |
Safety function
Repeated door closing |
If the lift can not close the door due to certain obstacle or interference, the lift will reopen or re-shut the door until sundries are eliminated. |
Power on re-leve ling |
A power failure might cause the lift to stop between two floors. However, upon recovery of the power, the car automatically moves to the nearest leveling floor. |
Overload holding stop |
When the car is overload, the buzzer rings and stops the lift in the same floor. |
Start protection control |
If the lift does not leave door zone within the designated time after it gets started, it will stop the operation. |
Inspection operation |
When the lift enters into inspection operation, the car travels at inching running. |
Up/down over-run and final limit protection |
The device can effectively prevent from the lift’s surging to the top or knocking the bottom when it is out of control. It results in more safe and reliable lift travel. |
Down over-speed protection device |
When the lift downs 1.2 times higher than the rated speed, this device will automatically cut off control mains, stop the motor running so as to stop lift down at over-speed. If the lift continues to down at over-speed, and the speed is 1.4 times higher than rated speed, safety tongs act to force the lift stop in order to ensure the safety. |
Upward over-speed protection device |
When the lift up speed is 1.2 times higher than rated speed, the device will automatically decelerate or brake the lift. |
Photocell protection |
In the door open and shut period, infrared light that covers the whole door height is used to probe the door protection device of both the passengers and objects. |
Emergency function
Emergency car lighting |
Emergency car lighting automatically activated once power failure. |
Five way intercom |
Communication amid car, car top, lift machine room, well pit and rescue duty room through walkie-talkie. |
Bell |
In emergency conditions, if bell button above car operation panel is continuously pressed, electric bell rings on top of the car. |
Fire emergency return |
If you start key switch in main landing or monitor screen, all the callings will be cancelled. The lift directly and immediately drives to the designated rescue landing and automatically opens the door. |
Man-machine interface
Micro-touch button for car call and hall call |
Novel micro-touch button is used for operation panel command button in the car and landing calling button. |
Floor and direction indicator inside car |
The car shows the lift floor location and current travel direction. |
Floor and direction indicator in hall |
The landing shows the lift floor location and current travel direction. |
Car assistant operation box |
It is used in the large loading weight lifts or the lifts with crowded passengers so that more and more passengers can use the car. |
Energy-saving function
Car ventilation, light automatic shut off |
If there is no calling or command signal within the stipulated time, the car fan and lighting will be automatically closed in order to save the energy. |
Remote shut-off |
The lift can be called to main landing (after finishing the service) through the key switch and automatically exists the service. |
- Q: Elevator to the second floor, when the man turned out and smiled at her. When the door closes, she suddenly darling up to the third floor .. The woman is dead. Q: Do not cancel the third floor of the case how can let her survive? More
- Shibi problem, why do not kill in the elevator, why the door closed also laugh knife also dig a knife. What a messy assumption
- Q: There are songs, the lyrics involved in "anyway, every day will take the elevator"
- The correct lyrics is "anyway, I will take the elevator every day", from the song "look at her". Basic information: Chinese name: Look at her album: TheRedShoes Release time: 2001 lyrics: Zhen Jianqiang Composer: Lei Songde Arranger: Lei Songde Lyrics: You are my girlfriend disappeared for a week do not give an account of it only two minutes to keep the elevator The girl is with me up the mountain You see her white gloves gently press the elevator fly the sky so high you have not thought of the same smile to me in every beautiful morning for my soul bath I want to see her What's the matter anyway I'll take the elevator every day I'll take a fancy to her You do not get angry anyway I want to love you Do not see you no matter how I want to catch up with your belt to miss You should not have the door Do not open I guess Her lipstick color so be considered love fall in love with her crimson hat Let me think that the elevator inside never worry I think the distance will be less and less if she will be sorry I pretend to read the newspaper
- Q: Respectively, under what circumstances
- Smoke staircase need to have pressurized air supply equipment, the need for a corresponding level of fire doors, the need for a certain area of the small room before the room. Closed stairs do not need to have these conditions. Smoke staircase set range: a class of buildings, more than 32m height of the two types of buildings (excluding units, corridor-style residential) and tower residential
- Q: How to set the elevator shaft
- Oh, you are asking the elevator shaft in the budget of the project problem, there are the following items 1, the implementation of steel reinforcement corresponding project 2, concrete concrete implementation of the corresponding project < ; 3, the template in the fixed in a proprietary, is the elevator shaft wall template, in practice, you can also use the shear wall project 4, elevator shaft frame This is the scaffolding in the project 5, you see the construction organization design, There is a corresponding process requirements, there will be no drawings such as bolts and other materials, this do not forget to calculate
- Q: There is no exhaust fan in the elevator
- No, there is a corresponding exhaust. There is no dedicated exhaust fan.
- Q: Do you want to be next to the elevator? What is the role?
- Fire elevator front chamber to consider the principle of positive pressure air supply near the shaft to reduce wind pressure loss
- Q: Assassin's Creed 4 The first off the elevator on how
- Into the elevator, aiming at the logo like wifi by E
- Q: On the elevator frame advertising, who can specifically talk about it?
- The most important thing is to see where your elevator ads are in the elevator. If it is in the office, like a car, cosmetics, mobile phones, watches, entertainment and so will do; if it is in the residential, tend to use some of the daily, such as the surrounding market, household items, jewelry, mobile phones, watches and so on.
- Q: What are the contents of the elevator property every day?
- 1) Various functions of the control box are normal. 2) the floor of the floor signal is complete, clear, monitoring device is operating normally. 3) The intercom with the fire center and the room is normal. 4) safety touch panel or photoelectric should be correct, lighting effective. 5) Car door and the car wall should be no collision, no friction. 6) car without clutter advertising. 7) The door should be safe and reliable, should be "room weight, idlers free" logo. 8) The room walls are complete, no holes. 9) The room should be ventilated and rainproof facilities, flat layer signs complete. 10) There are lighting devices, electrical outlets, fire extinguishers, intercom devices and so on. 11) There are elevator release wrench and wheel handle wheel, shaft lighting is good. 12) traction machine should be intact, cleaning, dripping oil should meet international standards. 13) The control cabinet should have no noise in the elevator operation. 14) The function of the switch is normal, oil twitch fleeing charcoal gongshou astringent abalone cup with oil. 15) car roof rope combination of complete, no rust, with anti-rust paint. 16) The door of the door deputy door lock is complete, the installation is correct, no rust. 17) each door door and foot cover slide complete. 18) floor and door frame without friction, no collision. 19) rail bracket without loosening, pressure plate firmly. 20) The horizontal distance between the shaft wall and the car's ground can not exceed the standard. 21) The station indicator signal button is clear and complete. 22) pit lighting, emergency stop switch is valid. 23) compensation chain, the buffer should be safe and reliable. 24) size track with oil access device.
- Q: What are the eight systems of the elevator!
- Eight systems: traction system, guidance system, car, door system, weight balance system, electric drive system, electrical control system, safety protection system
1. Manufacturer Overview
Location | Zhejiang,China (Mainland) |
Year Established | 2007 |
Annual Output Value | Above US$100 Million |
Main Markets | 90.00% Domestic Market 2.90% Southeast Asia 2.10% Eastern Asia 1.50% South America 1.20% South Asia 1.00% Africa 0.60% Mid East 0.50% Central America 0.20% Oceania |
Company Certifications | Machine Roomless Passenger Lift CE Certificate; Passenger Lift CE Certificate |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai port |
Export Percentage | 11% - 20% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese, German |
b) Factory Information | |
Factory Size: | Above 100,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Average |
Send your message to us
Freight Elevator VVVF
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Set set
- Supply Capability:
- 1000 Sets per Month set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords