Panoramic Elevator (Square Type)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Unit unit
- Supply Capability:
- 200 Units per Month unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Detailed Product Description
1.German technology AC-VVVF Drive
2.Lower noise
3.Steady running
4.Competitive price
5.Good for sightseeing
Product name | Model | Speed (m/s) | Rated load (kg) | ||||
Panoramic elevator | WO20 | 2.00 | ---- | ---- | 800 | 1000 | ---- |
1.75 | ---- | 630 | 800 | 1000 | ---- | ||
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- | ||
Small machine room Panoramic elevator |
WO30 | 2.00 | ---- | ---- | 800 | 1000 | ---- |
1.75 | ---- | 630 | 800 | 1000 | ---- | ||
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- | ||
Machine room less Panoramic elevator |
WON30 | 1.75 | ---- | 630 | 800 | 1000 | ---- |
1.60 | ---- | 630 | 800 | 1000 | ---- | ||
1.00 | ---- | 630 | 800 | 1000 | ---- |
- Q: 1. Analysis of the reasons for the breakage of the elevator wire rope 2 Is the steel wire rope broken and the rest should be replaced at the same time? Where is the standard downloaded? More
- It is recommended to use an elevator wire rope with 8 * 19S + FC, 8 * 19S + IWR, 8 * 19W + FC, 8 * 19W + IWR. The rope used for the elevator is generally divided into steel core and core. In the case of elevated height is not very high, the speed generally 1.75m / s below will use the core of the core. At a speed of 2m / s to 3m, you will use steel core. When the speed is higher, such as 6m / s or 8m / s will use the steel band
- Q: Whether the elevator can be combined with the fire elevator
- Choose to try to rely on convenience evacuation of the elevator. For the main part of high-rise civil buildings, the floor area of not more than 1500 square meters, should set up a fire elevator; more than 1500 square meters, less than 4500 square meters, should be set up two fire elevators; each floor area of more than 4500 square meters , Should be set up three fire elevator. The fire shaft of the fire elevator should be set separately, and no other electrical piping, water pipes, trachea or ventilation ducts shall pass. Fire elevator should be equipped with front room, the front room should be equipped with fire doors, so that it has a fire and smoke function. Fire elevator load should not be less than 1000 kg, the car's plane size should not be less than 1 m × 1.5 m, its role is to be able to carry large-scale fire fighting equipment and life-saving stretcher.
- Q: There is no exhaust fan in the elevator
- There are two fans on the top of the elevator car. However, some businesses in the decoration of the elevator car when the top closed, so the basic fan does not work.
- Q: Rated capacity of 1050KG elevator on the weight because of how much (we are Fu Shida Elevator 1.75m / s) more
- Generally depends on your weight on the weight of the block to determine the number of single weight from the building and the use of materials (cement or cast iron, lead) and other changes to the weight = car weight + 0.5 * weight - weight Box car weight according to the manufacturers reported that the different models of different weight, generally in the 600 ~ 1000 ? ? ?,? ? ?,00 ? ? ? ? ? ? ? On the weight of a 50KG, 26 or so
- Q: Inside the elevator inside the number of buttons "1" below a letter "B", what does that mean? Question added: "B" is optional? More
- Is the next layer of 1, generally refers to the frame because the layer of -1 said the basement, so casually choose a letter hunger and nail as a fixed layer
- Q: What is the size of a barrier-free elevator? As if to deep into the 2750 is it?
- Each of the elevator manufacturers are not the same as the civil size, generally to the arc of the old side of the turtle turtle turtle is said to be square or close to the square. Roadway plane size: about 2300mmX2300mm (wide X deep) (different manufacturers are not the same, this is only about size, specifically to ask the installation of the elevator manufacturers)
- Q: What does the elevator equipment code and registration code refer to?
- Is the same thing, refers to the elevator in the technical supervision bureau to register after the 20 registration number,
- Q: Do you want to be next to the elevator? What is the role?
- The airway next to the elevator should be the role of the smoke in the elevator when the fire is removed
- Q: Is the elevator not a box? Fall into the hoistway inside I do not understand, I do not even know what the road is ah! The Help out the question added: how people will fall? More
- The hoistway is the elevator car and the counter-running space, which is the bottom of the pit pit, the hole wall and the top of the boundary, see GB GB7025-1997; As for the fall into the shaft, it is because the elevator hall door is not open Be careful to fall off (mostly elevator practitioners) or because the fault did not close the door to fall (mostly owners).
- Q: What is the safety contact of the elevator? Where is the safety contact? What is the use? How does it work More
- Safe circuit, the normal state is through. All the places involving safety will have a contact, the engine room, the pit, the car door, each elevator door, all contacts in series together, any point off, the elevator can not move
Our elevator control system comes from Germany technology, it is very precise and efficient but operation is simple, it can be mastered by engineers easily. Our purpose is: Make qualified and safe elevator products for people. Up to Dec.1, 2012, we have exported more than 1000units elevators and 800units escalators to more than 30 countries markets. Most of elevators and escalators which had been installed are running very well.
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Panoramic Elevator (Square Type)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Unit unit
- Supply Capability:
- 200 Units per Month unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords