Monel 400 wire/ASTM B164/ Nickel Alloy wire
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Description
Monel 400
Chemical Element:
Ni 63.0min, Cu 28min~34max, Fe2.5max, Mn 2.0max, C 0.3max, Si 0.5max, S 0.024max
Characteristic as below:
Monel 400 is an extremely combination property that use for largest amount and most widely corrosion resistance alloy. This alloy in the hydrofluoric acid and fluoride gas medium with excellent corrosion resistance, as well as to the hot concentrated alkali. At the same time, is also corrosion resistant to neutral solution, sea water, air, organic compounds. An important feature of this is generally do not generate a stress corrosion cracking, good cutting performance.
Metallurgical structure
Monel 400 alloy is high-intensity single-phase solid solution.
Corrosion resistance
Monel 400 alloy in the fluoride gas, hydrochloric acid, sulfuric acid, hydrofluoric acid and their derivatives have a very good corrosion resistance property, and possess better corrosion resistance more than the copper alloy in the sea water. Acid medium: Monel 400 have corrosion resistance in less than 85% consistency of sulfuric acid. Monel 400 is an important material that resistant to hydrofluoric acid. Water corrosion: Monel 400 alloy in most corrosion cases of water, not only excellent corrosion resistance, but also less pitting, stress corrosion, the corrosion rate less than 0.025mm / a. High temperature corrosion: Monel 400 for the work of the highest temperature at about 600 degree in general in the air, in the high temperature steam, the corrosion rate less than 0.026mm / a. Ammonia: Monel 400 can be resistant to an hydrous ammonia and aminate conditions corrosion below 585 degree due to the high nickel.
Application field:
Monel 400 alloy is a multi-purpose material in many industrial applications:
1. Seamless water pipe in the power factory
2. Sea-water exchanger and evaporator
3. Sulfuric acid and hydrochloric acid environment
4. Crude distillation
5. Sea-water in the use of equipment and propeller shaft
6. Nuclear industry and used in the manufacture of uranium enrichment isotope separation equipment
7. Manufacturing hydrochloric acid equipment used in the production of pump and valve.
Our company supply monel 400 wire, monel 400 flat wire, monel 400 strip.
- Q: My home meter access line only 1.5 square copper heart line, is available? Because air conditioning only sleep at night when the open, the other only the refrigerator and 40W lights. Other electrical appliances do not open when sleeping. Thank you! More
- I am not professional, I am learning English, 1 about 732W it is not clear, should be able to use it, but you can ask the mechanic, installed meter asked, or you can ask You may know the door, but you still have to ask about the people who installed the meter, insurance a little.
- Q: i would like to know exactly where i can disconnect my wire feed that goes into my door. Theres a couple places i think maybe it comes undone, but i dont want to force anything and break a connector. i need to take off my door.
- in case you realize for a incontrovertible fact that that's unlocked then you particularly will ought to get interior the back of the motor vehicle and get rid of the trim panel from the hatch and look to be certain if the the linkage between the cope with and the latch mechanism has come aside. if that's the case once you examine it out, you will might desire to be certain why it got here aside. that's often because of the plastic clips that carry them mutually breaking. those clips could be bought at a Chrysler sellers areas branch for a somewhat low cost.
- Q: I have a wire heating up and wanting to burn that is going to the alternator (stator) . It is a black wire with a diode on it I think. I went to the john deere dealer and they first gave me a stator because they said that might be problem. It wasnt because i put new stator on and still same result. I took stator back.they checked old one and said it was good.rigged up some diode to put on it. I tried that and still wire wanting to burn up. I think maybe they give wrong diode? I have it figured out it can be only 2 things as all other wires have no shorts and this wire running from the stator is black, connects to a 4 prong plastic connector where it changes to red and goes to the solenoid, Is this wire suppose to be a hot wire where it connects to the plastic connector? I have photos of exactly what I am talking about if someone can help me I can send them the photos. It is in great detail taken with digital camera.
- if it starts to heat up which means you have a high resistance somewhere -- the diode is used to make sure the flow of power goes in one direction check the diode and make sure it is pointing the right way
- Q: i have a problem where my acc fuse keeps blowing and im tired of replacing fuses so what i was wondering is if it was safe to straight wire an interior light with an inline fuse and a toggle switch and would it cause any kinds of conflict
- It will not be a problem just make sure the wire doesn't touch ground(metal) anywhere and also keep a check on it for ware. If the wire touches metal after the inline fuse it will blow it. If it grounds before the fuse then it could cause a fire. So protect it well and it should be fine.
- Q: I am prepping it for a derby and accidentally cut the fuel pumps electrical wire harness thinking it was stereo or tail lights. I just want to hook it up to start it and move it to the shop where i can really tear into it. There are 4 wires. Black, purple, grey, and black w/ yellow stripe. I want to bypass the electrical connectors and just splice it into the wires that run along the drivers side floor. What color wire is what and what color do i splice it to?
- you will would desire to make certain in case you have potential and floor to the gas pump. regrettably you will would desire to drag the tank off to make certain the relationship. The helpful cord from the relay is a grey cord. the floor cord is a robust black cord. you are able to connect a attempt mild between the two terminals and turn on the significant. the sunshine could come on for extra or less 2 seconds and then pass off. Or in case you're cranking the engine, the attempt mild could be on once you're cranking. No mild,then you definately've a potential or floor concern. mild on, then you definately probable have a dud gas pump.
- Q: An incoming cable (line) is connected to a standard receptacle with the hot (black) wire attached to the upper screw (brass) and the white (common) wire attached to the lower screw (silver). The outgoing cable (load) is attached to the other two screws in the same manner. In my limited residential experience, the line cable will be attached to opposing screw contacts (upper 2 screws) with the second cable (load) attached to the bottom two contact screws on a standard electrical receptacle. In what conditions would these cable contacts be split like this? I have a short along this circuit somewhere and I am wondering if this is the problem?
- Actually that is an illegal wiring of a device in today's electrical field. All white (neutral) must not use a device for continuity. Proper wiring would be pigtailed or wire nutted. If the device fails so does the remainder of the circuit. losing the neutral on an appliance can lead to over voltage and fry the electronic power supply. My next question is do you have a short (breaker trips) or an open (no typical voltage across neutral and hot) And the worst offense of wiring is stabbing the wires in the back of the device. Never do this without a pig tail. The biggest reason trailer houses burn down is due to this huge wiring offense. Other problems you can search for: long nails or screws in walls, child puts long items through the back of the outlet. I have seen broken ground lead from plug shoved through back also. Mice chewing on wires to try and squeeze through holes. Smashed wires from GFCI being put in small metal nail on boxes of old construction. Just to name a few. The only time more then one screw should be used on receptacles is when you break the tab between the screws to split the receptacle.
- Q: anything in particular to worry about? besides killing myself. I bought the plug w/ the 3 loose wires sticking out as well as the new hot water line and elbow to replace the current copper line. the middle one looks like the green (ground) but i can't tell which one is the black or white one, they all have metal tips. Also, do i have to have the little plastic tops to twist the wires together? or electrical tape sufficient?
- Use wire nuts, NOT JUST TAPE. Invest in an inexpensive tester to determine which one is the hot lead - that connects to the black wire. To be safe, why not call a local handyman who has done this before if you are unsure? Water and electricity don't mix, especially if you miss grounding the unit or incorrectly switching the hot and neutral.
- Q: I had a small infestation of mice in my garage a few years back. I noticed a hole under the breaker box that looks like it was from the mice. Is it likely that they chewed on the wiring or was this just an entry point? How would I know without tearing out the drywall or pulling all new wiring?
- Do Mice Eat Electrical Wires
- Q: Bridge 380V strong wire, and now put into the cable to the signal interference?
- Heat shrink tube can be inserted into the cable, heat shrink tube is not much more than the cable on the line!
- Q: Four air-conditioning, two electric water heaters at the same time need to use the number of square wires more
- Air conditioning according to the calculation of 1.. the water heater each calculated by 2000W, respectively, to discuss: 1) air conditioning and heating and heating is not open and with two water heaters at the same time the current is: (1100 × 4 +2000 × 2) ÷ 220 ≈ 38A At this time the bus should use at least 6 square copper wire; 2) air conditioning to open the auxiliary heating and heating with two water heaters at the same time the current is: 2000 × 6 ÷ 220 ≈ 55A at this time the bus should use at least 10 square copper wire. So from the home point of view, you should choose is 10 square copper wire. Supplement, household wire diameter selection and power correspondence
Send your message to us
Monel 400 wire/ASTM B164/ Nickel Alloy wire
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords