Monel 400 wire/ASTM B164/ Nickel Alloy wire
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Description
Monel 400
Chemical Element:
Ni 63.0min, Cu 28min~34max, Fe2.5max, Mn 2.0max, C 0.3max, Si 0.5max, S 0.024max
Characteristic as below:
Monel 400 is an extremely combination property that use for largest amount and most widely corrosion resistance alloy. This alloy in the hydrofluoric acid and fluoride gas medium with excellent corrosion resistance, as well as to the hot concentrated alkali. At the same time, is also corrosion resistant to neutral solution, sea water, air, organic compounds. An important feature of this is generally do not generate a stress corrosion cracking, good cutting performance.
Metallurgical structure
Monel 400 alloy is high-intensity single-phase solid solution.
Corrosion resistance
Monel 400 alloy in the fluoride gas, hydrochloric acid, sulfuric acid, hydrofluoric acid and their derivatives have a very good corrosion resistance property, and possess better corrosion resistance more than the copper alloy in the sea water. Acid medium: Monel 400 have corrosion resistance in less than 85% consistency of sulfuric acid. Monel 400 is an important material that resistant to hydrofluoric acid. Water corrosion: Monel 400 alloy in most corrosion cases of water, not only excellent corrosion resistance, but also less pitting, stress corrosion, the corrosion rate less than 0.025mm / a. High temperature corrosion: Monel 400 for the work of the highest temperature at about 600 degree in general in the air, in the high temperature steam, the corrosion rate less than 0.026mm / a. Ammonia: Monel 400 can be resistant to an hydrous ammonia and aminate conditions corrosion below 585 degree due to the high nickel.
Application field:
Monel 400 alloy is a multi-purpose material in many industrial applications:
1. Seamless water pipe in the power factory
2. Sea-water exchanger and evaporator
3. Sulfuric acid and hydrochloric acid environment
4. Crude distillation
5. Sea-water in the use of equipment and propeller shaft
6. Nuclear industry and used in the manufacture of uranium enrichment isotope separation equipment
7. Manufacturing hydrochloric acid equipment used in the production of pump and valve.
Our company supply monel 400 wire, monel 400 flat wire, monel 400 strip.
- Q: component of electrical wiring system according the appropriate street light. the voltage power supply and herzt(hz) using for street light.
- Too many variables to answer that. In the US we use 60 Hz current. There are several types of lamps to choose from such as Mercury vapor, but I believe most US systems use 240 Vac.
- Q: have a clifford alarm/remote starter and it completely doesn't work. if it is taken out, will it possibly mess up my electrical wires and cause my car to be messed up since the wires in a car are touchy? the alarm was already installed by the previous owner when i bought the car and i have the papers of how he wired it
- It could mess things up. If you are not familiar with how they are installed, I would take it to someone who can remove it for you.
- Q: I have a 6 weeks old kitten and he is always biting me and the electrical wires. How can I stop him?
- Just go get tubing at Home Depot and run your wires through it. It protects the wires and your cat from being hurt.
- Q: i mean i know its SUPER dangerous but if you are trying to make a circuit and insert a wire into a socket, and if you don't touch it, could it still work?? im not saying im going to do this in real life, but i have to make a picture of a rube goldberg machine and would it work, if you didnt touch the wire?
- I kill you, if you do, said the hot wire. Yes, you could. Yes you could die. No, don't do it.
- Q: A puppy travel in the desert, found the poles, the results still suffocated, why?
- In the manufacturers where the cable is on the number of meters, the retailer's words are, up to give you some preferential prices.
- Q: I know it sounds weird but I like to do little projects here and there with any loose electrical stuff I have. you know. takes apart electronics I don't use and try to make a fun little project out of making something new and useful. And it happens that I have a large supply of unneeded ethernet and phone cables and I am ussually very good with this kind of stuff. but this has me stumped. O.o Can these wires be used at electrical wiring in a simple or complex circuit? I mean it makes sense. but I don't want to waste time and not have it work as I've never used them like that before.
- Yes and it is a very good idea for SMALL electrical prodjects. What you need to do is clip the 2 ends of the ethernet cord and throw them away. Then you need to strip the rubber case that is on the outside of the cables. Its about 1 MM thick so be careful. Use like a scissors and make a little shallow cuts around the cord (O and by the way we are stripping the case of the real cords right now). Do this every foot or two and pull the rubber case off. There should be many little cords in there called CAT 5. Take two of those cords out and strip the ends of them and you have two perfectly good cords to work with (you can use the other cords as well of course). Thats pretty much all you have to do. Hope this helps!
- Q: I am trying to completely remove a dishwasher. I don't want to replace it, just remove it and convert the space to shelf space. The electrical is hardwired to the dishwasher. I already have the breaker off and it can stay off indefinitely. How do I cap the wire ends so it will be safe if someone accidentally turns the breaker back on and those go live? Should I just use wire nuts? Thanks
- Possibly, but very doubtful, the detonating system itself needs more power than a AAA battery could possibly provide. Plus how would the battery detonate it? Like a timer detonator or what? Well you'd probably kill yourself then because it sounds like an immediate detonator. But probably not. The electrical charge is just to small even if it uses all of its energy in one short burst.
- Q: I just bought a house, and the area where the dryer needs to go only has a two foot electrical wire coming out of the wall. It's an old house, and it's possible these people just hooked those wires directly to the dryer without using an outlet. Is that possible? Or do I need to install those wires into a three prong outlet for electrical supply to my dryer?Thanks!
- Yes, it's possible to wire some dryers w/o a plug. However, it's not commonly done in residential settings as most people don't have an electrician around to disconnect it if it needs service or to be moved for some reason.
- Q: I do not want to break any nyc code law.
- Non metallic tubing as it is referred to is a protective layer for conductors. Legal depends on what you intend to do w/ it and what your local and state jurisdictions say is legal. It is generally used in wooden structures, like homes but only when the wire is subject to damage by human traffic. A green/bare ground is required in most cases to ground the appliance since the tubing is plastic. Most commonly seen used outdoors because of it non corrosive qualities and aesthetic appearance
- Q: What is the difference between a radiation wire and a wire without radiation?
- Metal rail or metal tank within the total cross-sectional area of the wire should not exceed 40% of its cross-sectional area, and the metal box containing the flow of wire should not exceed 30 16mm? wire diameter of 8mm, plus the maximum cross-sectional area after the insulation are: 502mm?; truncated area = (502 × 2) / 40% = 251mm ?; trunking a × b = 251/12 ≈ 209mm, × 12 of the trough as well
Send your message to us
Monel 400 wire/ASTM B164/ Nickel Alloy wire
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords