MINI Series Frequency Inverter 220v 380v from 0.4kw to 0.75kw
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 100000 kg/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Mini Sensorless Vector Frequency Inverter
Voltage and power range:
3phase, 380v: 0.4~5.5kw
3/1 phase, 220v: 0.4~3.7kw
Output frequency range: 0.00Hz-400.00 Hz
TechnicalAdvantage
Control mode
(1) VF control: Multipoint VF curve. This apply to the situation that one frequencyinverter drives multiple motors, such as fan, water pump, engraving machine,injection molding machine etc.
(2) Open-loop vector control: Steady speed with highprecision, wide range of speed governing, as the speed ratio is 1:150 and frequencyis 0.5Hz, we could output 150% rated torque. Good dynamic performance.
TechnicalParameter
MODEL | Input voltage | Output current (A) | Adopter motor KW |
SVF-MN0.4S/T2B | Single or three phase 220V±15% | 2.5 | 0.4 |
SVF-MN0.75S/T2B | 5 | 0.75 | |
SVF-MN1.5S/T2B | 7 | 1.5 | |
SVF-MN2.2S/T2B | 9.6 | 2.2 | |
SVF-MN3.7S/T2B | 17 | 3.7 | |
SVF-MN0.4T4B | Three phase 380V±15% | 1.2 | 0.4 |
SVF-MN0.75T4B | 2.5 | 0.75 | |
SVF-MN1.5T4B | 3.7 | 1.5 | |
SVF-MN2.2T4B | 5 | 2.2 | |
SVF-MN3.7T4B | 8.8 | 3.7 | |
SVF-MN5.5T4B | 12.8 | 5.5 | |
SVF-MN7.5T4B | 17 | 7.5 | |
Relatedparts
Application Fields
SVF-MN series frequencyinverter could be widely used in the industry of food, packing, textile,engraving machines, washing machine, offset machine and rolling door etc.
EMC Standard Introduction
According to the requirements of national standard GB/T12668.3, the drive need to comply with electromagnetic interference and anti-electromagnetic interference two requirements. The existing products of the company execute the latest international standards: IEC/EN61800-3:2004(Adjustable speed electric SVFl power drive systems-part 3:EMC Requirements and specific test methods) which is equivalent to the national standard GB/T12668.3.
IEC/EN61800-3 inspects the drive from EMI and anti-EMI two aspects, EMI mainly tests the drive's radiation, conducted and harmonic interferences ( Corresponding the civil drive has the requirement ). Anti-EMI mainly tests the drive's conducted immunity, radiation immunity, surge immunity, fast mutant burst immunity,ESD immunity and power low frequency end immunity (Specific test items are: 1. the experiment of input voltage dips, interruptions and changes immunity; 2, the experiment of commutation notches immunity ; 3, the experiment of harmonic input immunity ; 4, the experiment of input frequency change; 5, the experiment of input voltage unbalance; 6, the experiment of input voltage fluctuation).
According the stringent requirements of the IEC/EN61800-3 to test and according instructions shown in the 9.3 to install, Our products will have a good EMC for the general industrial environment.
- Q: Laptop adapter
- This principle is not, try, look at how the charge situation, if you can charge, can be filled, just a long time, to no harm However, the heat may be high, long-term so, there is a risk
- Q: East yuan 7200GS inverter start 11KW 4-pole motor and 2-pole motor need to modify what parameters?
- If you use the environment is relatively poor, it is recommended that you use Austrian St. sealed inverter, this inverter can be moisture, dust, water, oil, corrosion.
- Q: How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
- Yes, but it is not necessary, if it is old motor that is another matter, tell you that you can use, but can not be in the frequency conversion process for the pole, this will cause the inverter protection or failure
- Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
- Theoretically reverse seems to be possible, but the operation will be normal, you can do experiments to try what is the result. Various manufacturers of the inverter may be the treatment of this problem will be different.
- Q: Is the inverter output current proportional to the output torque?
- When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
- Q: Can the laptop 1.3a power adapter be used on a 1.5a device?
- Theoretically impossible, because the power is small, but if it is a short period of time is possible, a long time to die.
- Q: How to disassemble the notebook power adapter
- 3, then open the shell of the power adapter, you can see the adapter circuit outside the package with a copper shield, with a knife to cut the shielding tape on the tape, and then use the soldering iron shield and the internal circuit board connected to the two Solder joints, you can remove the shield.
- Q: 22kw.2 pole fan can use Fuji inverter?
- Fan with Fuji? Money more people silly ... no comment ..
- Q: 400w 6-pole motor should be equipped with much of the inverter?
- Under normal circumstances, the market are sold on the inverter are based on the common 4-pole motor matching, when to match the 6-pole motor, the inverter to a large power level, which is 400W of the first-class power 0.75KW, and so on
- Q: The emitter E of the inverter inverter module and the AC output U are not directly connected together
- Pairs of modules are connected in a phase branch The phase output is derived from the neutral point between the modules
Send your message to us
MINI Series Frequency Inverter 220v 380v from 0.4kw to 0.75kw
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 100000 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords