• Raw Materials for Refractory:Metallurgical Grade Silicon Carbide Supplied by CNBM System 1
  • Raw Materials for Refractory:Metallurgical Grade Silicon Carbide Supplied by CNBM System 2
Raw Materials for Refractory:Metallurgical Grade Silicon Carbide Supplied by CNBM

Raw Materials for Refractory:Metallurgical Grade Silicon Carbide Supplied by CNBM

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
2000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:

China (Mainland)

Brand Name:

CNBM

Model Number:

CF180# 240# 320# 800# 1200#

Material:

SIC

Usage:

Lapping, Polishing,Blasting, Refractories

Abrasive Grain Sizes:

46#..1200#...2000#..2500#

color:

black and green

hardness:

9.15 mosh

melting point:

2250

Packaging & Delivery

Packaging Details:bags, cartons
Delivery Detail:15-20 days

Specifications

silicon carbide Size Available: 
F10-F220,F240-F1200 
Other special size could be supplied as required.

1.used for made abrasive products
2.professional manufacture
3.prompt reply-within 24hours
4.prompt delivery-within 15days.
GritSiCF.C.Fe2O3
F12-F9098.50%min0.20%max0.60%max
F100-F15098.00%min0.30%max0.80%max
F180-F22097.00%min0.30%max1.20%max
F230-F40096.00%min0.40%max1.20%max
F500-F80095.00%min0.40%max1.20%max
F1000-F120093.00%min0.50%max1.20%max
P12-P9098.50%min0.20%max0.60%max
P100-P15098.00%min0.30%max0.80%max
P180-P22097.00%min0.30%max1.20%max
P230-P50096.00%min0.40%max1.20%max
P600-P1500095.00%min0.30%max1.20%max
P2000-P250093.00%min0.50%max1.20%max
Black Silicon Carbide is brittle and sharp and has electrical and heat conductivity in some degree.

Aplications :
Black Silicon Carbide is suitable for make grinding wheels, cutting wheels, mounted wheels, oil stone, abrasive media, and also suitable for surface grinding, lapping or polishing. 

The abrasive products made of it are suitable for working on Cast Iron, Non-ferrous Metal, Rock, Leather, Rubber, Wood, Ceramic, etc.

Black Silicon Carbide is also broadly used as high-grade refractory material and metallurgical additive. 

metallurgical grade silicon carbide supplied by cnbm


Q: How many kinds of refractory materials are there in the EI?
I suggest that you contribute articles to foreign SCI journals for the odds are better, and generally the articles that fill the bill will not be rejected. The traditional refractory materials can contribute to EI journal. If being rejected by EI journal, you can also contribute to Russia's journal Industrial Ceramics and Refractories. I didn't contribute to the Journal of Wuhan University of Science and Technology, the receiving cycle is almost 3 to 4 months. Though the impact factor is low, domestic EI journal is not so good, it is still SCI journal. This is my own experience, please take my advice. The best journals are the Journal of the American Ceramic Society and the Journal of the European Ceramic Society, I heard that they are not bad. But the best domestic EI refractory material journal is the Journal of The Chinese Ceramic Society. It is very long, but if it belongs to your university, it is another pair of shoes. Journals now all want to have materials about functional ceramics, and they don't want Chinese articles, if your English is not well enough, you can choose Ceramics International and Japan Ceramics but they have strict manuscripts reviewing standards.
Q: How long is the fire resistant limit for ultra thin fire retardant coating?
The fire resistant limit of ultra-thin fire retardant coating is 1.5 hours, generally fire resisting time for thin fire retardant coatings does not exceed 1.5 hours. If the time exceeds 1.5 hours, thick fire resistive coating should be uesd. There is no detailed stipulation for ultra-thin fire retardant coating, and the thickness of the inside is the fire resistance limit shall reach certain time(at least). If fire resistance limit is 2.5 hours, the thickness shall be 4.9mm. If the fire resistance limit is 2 hours, the thickness is 3.5mm. If fire resistance limit is 1.5 hour, the thickness should be 1.75mm.
Q: I want to consult the fire resistant level standards of external wall thermal insulation materials.
1, The building with the height larger than or equal to 100m, should have the A-level combustion performance. 2, The thermal insulation material of the building, with a height larger than or equal 60m and less than 100m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each level should set horizonal fire barrier zone. 3, The thermal insulation material of the building, with a height larger than or equal to 24m and less than 100m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each two levels should set horizonal fire barrier zone. 4, The thermal insulation material of the building, with a height less than 24m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each three levels should set horizonal fire barrier zone. I hope my answer will help you. Thank you!
Q: Why does refractory need to add coarse firstly and then add fine aggregate?
Oh, adding coarse aggregate first is to select good material to make aggregate, and the rest cna be made into fine aggregate. Because if it contains impurities, once being sintered, the appearance will be affected, but fine aggregate does not have this impact.
Q: How to determine the fire resistance rating of the aluminium-plastic?panel?
The fire resistance rating of the aluminium-plastic?panel is determined by two indicators, namely national compulsory standard of GB8624 "Building Materials Combustion Performance Grading Method ", and GB/T17748 "Aluminium-plastic?Composite Panel National Standard" . Classifications of combustion performance of building materials in our country are as follows: A class: Incombustible building materials; B1 class: Flame-retardant building materials; B2 class: combustible building material; B3 class: flammable building materials. The fire resistance rating of the aluminium-plastic composite panel shuld be no less than B1 class. 1. Detection indexes and requirements of fireproof aluminum-plastic composite panel (B1 class): (1) Conduct the test according to GB/T8625-88, the average leftover length of each test specimen should be more than 150mm, (any test piece should have leftover length), and the maximum average flue gas temperature of each test should be no more than 200 ℃; (2) Conduct the test according to GB/T8626-88, flame hight indicators.
Q: Fire resistance and evaluation of refractory for casting
Because of their different shapes and conditions, various refractories are used to explain their fire resistance with different indexes, and the test methods are also different. In general, the refractoriness of unshaped refractories; the softening temperature of formed refractory products; the change of the reheating line of heat insulation materials at high temperature.
Q: What do refractory materials include?
It is so difficult.
Q: What thickness is needed of the ultra-thin fireproof paint with a fireproof time of 2.5 hours?
The thickness of steel structure fire retardant coating hasn't been regulated in the steel structure application specification (CECS24:90). The above thickness refers to a certain thickness that must (at least) achieve a certain time of the fire resistance. The thickness of fire-retardant coating in engineering is generally determined according to factory inspection report. We use thin steel structure fire retardant coating: 2.5 hours' fire resistance with the thickness of 4.9 mm; 2.0 hours' fire resistance with the thickness of 3.5 mm; 1.5 hours' fire resistance with the thickness of 1.75 mm; 1.0 hours' fire resistance with thickness of 1.17 mm. I hope I can help you.
Q: Does anyone know the fire endurance of steel stud partition?
Indeed ① Dragon Brand gypsum board fire-resistant partition: Its fireproofing extreme time is 4 hours, suitable for firewalls of a variety of public buildings, public exit passageway and other partitions, which meets the first level of fire protection standard ② fireproofing and pressure-resistant partition: Refers to the partition which can withstand momentary gas shocks of over 1200pa , mianly used for the room partition with inert gas fire-fighting needs, such as equipment rooms. The pressure-resistant degree of fireproofing and pressure-resistant partition of Beixin Building Materials can be up to 4800Pa, especially suitable for high-rise fireproofing.
Q: What's the A class fireproof and thermal inuslation matertial for external wall?
First, external wall thermal insulation material: 1. silicate insulation material; 2. glue powder polyphenyl granule; 3. cement cystosepiment with the use of steel wire gauze (polystyrere); 4. extruded sheet; Second, roofing materials: 1. xps extruded sheet; 2. EPS foam board; 3. perlite and perlite brick; 4. vermiculite and vermiculite brick; Third, materials for heating power and air conditioners: polyurethane, rubberplastic sponge, polyethylene, polystyrene foam, glass wool, rock wool; Fourth, steel structure material: polystyrene, extruded board, polyurethane board, glass cotton lap felt, etc.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches