• Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price System 1
  • Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price System 2
  • Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price System 3
  • Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price System 4
  • Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price System 5
Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price

Raw Materials for Refractory:88% Alumina 60 Mesh Calcined Bauxite with Low Price

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
30000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

88% Alumina 60 Mesh Calcined Bauxite with Low Price

 

Specifications

1.    We directly supply calcined bauxite 

2.    Al2O3:70%/75%/80%/85%/86%/88%/90% 

3.    Size:0-1-3-5-8-10/200mesh/325mesh/400mesh/500mesh

 

Size:

Lumps /Grains:0-1mm,1-3mm,3-5mm,5-8mm /Powders:100mesh, 200mesh,325mesh

 

Product Description:

Bauxite, alumina or bauxite miner , main ingredients are aluminum oxide, hydrate alumina containing impurities,

is an earthy mineral.White or grey, brown yellow or light red by iron.From 4 to 3.9 g/cm3 density, hardness, 1 ~ 3, opaque, very brittle.

Very difficult to melt.Insoluble in water, soluble in sulfuric acid, sodium hydroxide solution.Mainly used for aluminium, refractory material.

 

Calcined Bauxite Grade:

Shaft Kiln Bauxite

Rotarty Kiln Bauxite

Round Kiln Bauxite

 

Packaging & Delivery

Packaging Details: In bulk or in 1-1.25mr bag

 

Product Pictures:


88% Alumina 60 Mesh Calcined Bauxite with Low Price

88% Alumina 60 Mesh Calcined Bauxite with Low Price

88% Alumina 60 Mesh Calcined Bauxite with Low Price

88% Alumina 60 Mesh Calcined Bauxite with Low Price


Our Service:

1. Your inquiry related to our products or prices will be replied in 24hours.

2. Manufacturer with large capacity, ensure the fast production cycle after confirmed the order.

3. Our professional technicians will answer your entire enquiry in patient.

4. To meet the refractory solutions, we can serve as your instructions.

5. Protection of sales area and private information for our entire customer.

 

If you’ve kind enquiries, please don’t hesitate to let us know. ^_^


Q: How to divide fire rating of decorating materials ?
The combustion performance of building materials is divided into the following grades by the national standard GB8624-97: level A: incombustible building materials, almost no burning material. Level B1: Flame retardant building materials, such kind of materials are effective in flame retardance. It is difficult to fire in the air in the case of open flame or under high temperature, it is not easy to spread quickly, and when the fire source is removed , the fire stopped immediately. Level B2: combustible building materials. Combustible building materials are effective in flame retardance. It will immediately burst into flames in the air in case of fire or under high temperature, and it is inclined to lead to the spread of fire, such as wooden, wooden frame, beams, wood stairs,etc. Level B3: Flammable building materials: they have no effect in flame retardance, easy to burn, fire risk is very huge.
Q: Are the specification of fireclay bricks and ordinary clay brick the same?
Do you want to know whether the specifications of fireclay bricks and ordinary clay brick are the same?
Q: What's the definition of fire endurance of the fire-resistant coating for steel structure?
1. Fire endurance. Conduct fire resistance test of any building component according to the standard time-temperature curve, and the time when it is subjected to the fire to the time when it loses support capability or fire insulation function or its integrality is destroyed is referred to fire endurance. 2. Steel has relatively low fire endurance which is usually 0.25h only, namely 15 minutes; 3. Of steel structure buildings, steel can be used as beams, pillars, etc. but its fire endurance is not enough (usually these components have higher requirement on fire endurance, and take pillar as an example, it is usually demanded that the fire endurance should be 2-3h), and under this condition, it needs to brush fire retardant coating so as to raise the fire endurance. As to the specific quantity or types of the fire retardant coating, it is decided upon the actual conditions. In short, the building material needs to meet the required fire endurance of the buildings.
Q: Is the refractory reached British BS standard and used for cables in China at present ceramic silicone rubber?
The texture should be designed according to the British relevant BS standard; crosslinked polyethylene or ethylene propylene rubber under 6600V to 19000 / 33000V is not necessarily ceramic silicone. The rated voltages of a small amount of smoke and corrosive gases from 3800 & # 47 when the BS 7835-2000 is affected by fire.
Q: What is the difference between the fire?rating and the fire resistant level of the fire-fighting equipment?
Fire rating and fire-fighting rating are the misnomer to the building fire resistant level. The building fire risk is measured by fire resistant level. The article 3.2.1 and 5.1.7 of "Architectural design code for fire protection" have made provision respectively on the fire resistant level of plant (the storeroom) and civil construction. Article 3.0.2 of "Code for fire protection design of tall buildings" has made provisions on the fire resistant level of tall buildings. Fire resistance rating of the building is divided into four levels. Standard of fire resistance rating is determined by the combustion performance and fire resistance of the main housing member. Level one or two are in accordance with the Article 1.0.2 in this specification.
Q: Who knows the fire endurance of B-level fireproof doors and windows?
B-grade fireproof windows refer to those fireproof windows whose fire retardant limit is not less than 1 hour. Technical requirements: I. Materials and Accessories (1) Window frame should have a certain strength to ensure the integrity and stability of the steel frame or the wood frame. (2) Steel frame and mound layer can employ galvanized?steel?sheet or stainless steel plate. Its selection criteria should be in line with the stipulation of the Article 5.1 of GB12955 "General Technical Requirements of Steel Fireproof Doors". (3) The selection standard of wood frame and mound layer should be in line with the provision of Article 5.1.1 of GB14101 "General Technical Requirements of Wooden Fireproof Doors". (4) Filling materials inside steel frame and wood frame should be non-combustible materials.
Q: Does the aluminum silicate thermal insulation material fireproof?
Yes, because of its low heat conductivity coefficient, and good thermal insulation, it can be setting fire.
Q: What are the additives and recipes of refractory?
Water reducing agent is to evidently reduce mixing water content while keep the slamp value of refractory castable almost invariant, also known as fluid loss agent. Water reducing agent itself cannot have chemical reaction with material component or compose new chemical compound, but it just seemingly has physical and chemical reactions. The binding agent of refractory castable is calcium aluminate cement combined with clay and oxide micro powder. In commonly used water reducing agents, the inorganic includes sodium pyrophosphate (Na4P2O7), sodium tripolyphosphate (Na5P3O10), sodium hexametaphosphate [(NaPO3) 6], super sodium polyphosphate (Na2P4O11), sodium silicate (Na2O · nSiO2 · mH2O), and so on; the organic includes lignosulphonate water reducer (sodium lignosulphonate, calcium lignosulphonate); naphthalene water reducer (naphthalene sulfonate or naphthalene homologues with formaldehyde condensate): water soluble resin water reducing agent (sulfonated melamine formaldehyde resin, abbreviated as composite of melamine water reducer).
Q: Who knows about the B-level fireproof insulation materials?
Commonly used B-level materials: Molding polystyrene foam, extruded polystyrene board, gelatine powder polyphenyl granule heat insulating slurry. Although the polyurethane is not the commonly used material, but the 9mm composite of monolayer gypsum board and PU insulating material can reach B-level.
Q: How to divide fire resistant level of fire door?
The classification of fire resistant level of fire door: Grade A is not less than 1.2h. Grade B is not less than 0.9h. Grade C is not less than 0.6h. It is suitable for fire door with different levels: Grade A: Equipment room (such as fire-pump room,power distribution room, generator room, smoke control fan room, etc) door, fire?compartment, door on firewall; Grade B: Eclosed staircase, front door of stair room, smoke-proof?staircase and fire elevator share lobby door, front door of fire elevator, household door which directly opens to front room or shares room; Grade C: The vertical shaft door, such as strong electric wells, weak electric wells, pipe shaft door and air conditioning facilities. I hope this information can help you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords