Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
The general MV VFD has the following protection functions and features:
Overload and over-current
Phase loss and grounding
Over voltage
Overheat
Current limit
Redundant control power supply
Cell Bypass (optional)
Cabinet door alarm
Phase-Lock function
Synchronous Switching between VFD and Grid system
Soft start of motor
High efficiency >98% (VFD at full-load)
Electrical Isolation by the optic fiber
Built-in PID regulator
RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc
Accurate fault records, easy to check fault history
Compact structure and layout, customized design is available
- Q: Inverter alarm a043, how is it
- When there is a signal failure, if necessary, use DTI Board, if necessary, change P215 In addition, for the synchronous motor (P095 = 12): the inverter is released until the motor is at rest
- Q: The laptop power adapter is burned
- To be sure, the power adapter has a problem ~ ~ I suggest you if the warranty period to go after the sale of a ~ ~ If the insurance on Taobao Amoy on a ~ ~ ~
- Q: 2 pole 0.75 kW motor can increase the speed through the inverter?
- 2-pole motor speed of about 2900 r / min or so, 4-pole motor speed of about 1400 r / min or so, which are in the case of 50HZ,
- Q: Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
- but the use of the inverter is based on changes in the load by changing the frequency of power into the motor at any time speed control, you can achieve a smooth and accurate stepless speed control is Now widely used in a speed control method, especially for the load often change or often in the light load operation of the motor.
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This is not a fault! Only after the inverter receives the base block signal, it is not output!
- Q: The Schneider inverter reports the nlp command
- Schneider inverter reported nlp ??? main circuit no electricity 1 re-power up 2 connected to the DC reactor terminals PO, PA / + between the short wiring, the main circuit can not be powered
- Q: Who knows how the inverter is calculated?
- Quadrupole motor synchronous speed is: 1500 r / min, but the actual motor speed will be more than 14 turn.
- Q: How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
- Beijing easy to create a website with Siemens inverter selection manual! You can log on online! Or contact them directly, they will give you professional answers!
- Q: Laptop power adapter is used to do what
- Power and charge the notebook. Equivalent to power, mobile phone charger.
- Q: How to make the motor speed (control speed), can not use frequency
- In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.