Medium Voltage Drive VFD 1800KW 6KV HIVERT-Y 06/220
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
The general MV VFD has the following protection functions and features:
Overload and over-current
Phase loss and grounding
Over voltage
Overheat
Current limit
Redundant control power supply
Cell Bypass (optional)
Cabinet door alarm
Phase-Lock function
Synchronous Switching between VFD and Grid system
Soft start of motor
High efficiency >98% (VFD at full-load)
Electrical Isolation by the optic fiber
Built-in PID regulator
RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc
Accurate fault records, easy to check fault history
Compact structure and layout, customized design is available
- Q:What is the difference between AC and DC frequency converters?
- Advantages and disadvantages: Advantages: inverter air conditioner with variable frequency power supply, inverter compressor, electronic expansion valve and microcomputer technology, the organic combination of air conditioning to further improve the performance, the use of room temperature fluctuations, better comfort, the better Power supply voltage fluctuation is not sensitive, the compressor starts, the general non-stop, cooling capacity in the range of 35% to 117% change, to avoid the frequent open air-conditioning, to extend the life of the compressor, while efficient, Features. Disadvantages: the price is more expensive, compared with ordinary air conditioning, about 1/3 to 1/4 of the price, at the same time, because the inverter air conditioner control system and frequency conversion system is more complex, higher requirements for components, compared to ordinary air conditioning , Inverter air conditioner failure rate is high, and, due to the use of frequency conversion technology, at the same time, will produce harmonic pollution. What is DC inverter air conditioner? DC inverter air conditioner is relative to the AC inverter air conditioner, in fact, its name is not correct, because the DC and no frequency, it is by changing the DC voltage to adjust the compressor speed, thus changing the air conditioning cooling capacity, It can only be said to be a DC variable speed air conditioning, not strictly in the sense of inverter air conditioner.
- Q:Octopus AC Servo motor can be driven with ordinary inverter?
- If it is synchronous motor, it depends on whether you choose the inverter is compatible with the synchronization machine, most of the incompatible. As you said the situation, the motor 8 pole, may be synchronous motor. Specifically, you can compare the rated speed and rated frequency to see if there is a slip rate to determine whether it is synchronous or asynchronous motor.
- Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
- So that mainly depends on your application and the frequency of work in the number.
- Q:Can the inverter stop intermittently during operation? If so, how to connect and set up
- Look at your inverter manual, because the inverter is not a simple wiring can run, first of all have to know that a few are external terminals (inverter input terminals),
- Q:Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
- 6-pole motor synchronous speed of 1000 r / min, the actual motor speed is lower than the number, the actual speed is required to 500 r / min, then the motor and passive pulley diameter ratio of about 1: 1.6 or so, and then specific With the inverter to speed up to achieve the purpose, please refer to.
- Q:30 kW 6 pole frequency motor torque is how much
- Look at the motor sample or nameplate, above some Different manufacturers of the motor may be different I have a sample on hand, 90KW, six pole, frame number 315M1, rated current 168A, rated torque 859.4 And then look at your inverter performance and motor performance, and can generally be overloaded to the rated torque of 150%
- Q:Laptop adapter
- The interface of the second adapter is the same as the first one And although the two numbers are not the same but the number of V on the line is the same as the interface
- Q:Inverter principle eff23
- For vectors such as vector-controlled frequency converters that require a lot of computation, there is sometimes a need for a torque calculation CPU and some corresponding circuits. Frequency control is by changing the motor stator winding power supply to achieve the purpose of speed.
- Q:22kw.2 pole fan can use Fuji inverter?
- according to the rated name of the fan brand and the inverter rated current control, select the current value match, or slightly larger The
- Q:The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
- 4, high-speed motor: high-speed motor running process will produce a large number of harmonics, enhance the output current of the inverter, resulting in a lot of heat. Therefore, the inverter selection is also larger than the ordinary one gear. 5, explosion-proof motor: In some mines, oil extraction environment, the frequency conversion system is explosion-proof motor, the choice of inverter should use the explosion-proof function of the inverter, and the inverter placed in a safer place. 6, the degree of protection: for dust, wet applications, inverter selection should pay attention to its protection level. Or choose Ampang letter AMB inverter, the fan can also run in the water. 7, single-phase motor: When the scene using single-phase motor, the inverter useless. 8, variable pole motor: When the field using variable pole motor, the inverter selection should ensure that the maximum operating current should not exceed the rated current of the inverter
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Medium Voltage Drive VFD 1800KW 6KV HIVERT-Y 06/220
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords