Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 50 set
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Structure of Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V
The CXF series of vertical axis maglev wind turbines undergoes a continuous improvement process, which incorporates exterior design, utility design, electrical engineering, dynamic engineering, power mechanics, aviation air engineering, wind tunnel testing, lightening protection, computer simulation techniques and other multiple specialities. Under the light theory of magnetic levitation technology, fan motor will be rotated by wind power without any mechanical friction. Since the generator has no lubricant and no gear, the Magleve wind turbine are high-performance power generation, smooth operation, which is a milestone for a new age of power technology.
2. Main Features of Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V
* Ideal for both of residential and commercial applications as well as off grid and on grid power systems.
* The unit provides a durable, reliable, and fully customized hybrid solution to Telecoms Base Receiver Station (BTS), Charging Station by Solar and wind and also very suitable for power supply to home
* Intelligent control system with active protective functions
* automatically lower rotational speed during strong winds
3.Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Specifications:
tems | CXF600 |
Rated power | 600W |
Dimension (Height/Diameter) | Ø1540mm / 1320mm |
Weight | 50 kg |
Blade material | Aluminum Alloy |
Blade quantity | 7 (3 Darrieusand 4 Savonius) |
Swept area ㎡ | 0.30 |
Min starting wind speed | 1.3 m/s |
Cut-in wind speed | 3.5m/s |
Rated wind speed | 13m/s |
Cut-off wind speed | 15m/s |
Survival wind speed | 60m/s |
Generator type | AC,3Phases |
Controller Output Voltage | 24V/48V |
Controller Braking System | 3-phase short circuit by NFB brake |
Ambient Temperature | -40~50 ℃ |
Noise | Less than 40dB |
Annual Energy Production (@ 5 m/s wind speed ) | about 1500 kWh |
4. Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Images
5. FAQ
Why to choose vertical axis maglev wind turbine ?
Re: You can find the answer in the following table
Comparison between HAWT AND MVAWT | ||
Item | Horizontal axis wind turbine (HAWT) | Maglev vertical axis wind turbine (MVAWT) |
Starting wind speed | High(≥3m/s) | Low(1m/s) |
Wind conditions required | Require stable wind direction | Any wind direction |
Encountered turbulence | Efficiency is reduce | Efficiency is not affected |
Power stability | Changing by wind direction | Without any wind effect |
Noise | Large (More than 45dB) | Low noise of less than 40dB thank to maglev frictionless technology |
Product appearance | Ordinary | Beautiful |
Installation height | High (need to avoid the terrain turbulence) | Low (not influenced by turbulence) |
Installation location | Open area like suburb | Any locations |
Generator material | Plastic or composite | metal |
Structure strength | Poor (easy to broken) | High(double strengthen arm) |
Resistance of wind speed | Poor(about 40 m/s) | High |
2. Is it hard to install the wind turbine?
Re: System can be assembled in under an hour , without any welding; and ingle or multiple unit connections for greater energy generation. In addition, it is easy for connection with PV systems
- Q: The production and transportation process of electric power
- The equipment of the two system comprises a measuring device, a control device, a relay protection device, an automatic control device, a DC system and necessary auxiliary equipment. Power system voltage level has 220V, 380V (0.4 kV), 3 kV, 6 kV, 10 kV, 20 kV, 35 kV, 66 kV, 110 kV, 220 kV, 330 kV, 500 kV, 750kV, 1000kV. With the improvement of motor manufacturing process, 10 kV motor has been mass production, so the use of kV, 6 kV has been less than 20 kV, 66 kV is also rarely used. The power supply system is 10 kV and 35 kV. Transmission and distribution system to 110 kV or above. Power plant generator has 6 kV, 10 kV and, with a total of 20 kV, users are 220V, 380V (0.4 kV) low voltage system 20kV.
- Q: Complete sets of power equipment life of the country what are the provisions for the aging of the equipment how to deal with, there is no standard?
- . For example, according to the international standard requirements of the stage mechanical engineering life is 50 years. In fact, the service life of the equipment is related to the use of the equipment.
- Q: Under the same voltage level, the rated voltage of the equipment is not exactly the same
- For different electric appliances, rated voltage may be different, commonly used for 220V, 280V, and some appliances used in not rated voltage can still work, but not up to the ideal working condition, rated voltage and the voltage at both ends of the electric appliance has nothing to do with.
- Q: I would like to set up a power engineering Co., Ltd., do not need to know what the scope of business
- Domestic thermal power, hydroelectric power generation, power transmission and power supply, energy saving, environmental protection, industrial and civil buildings, intelligent buildings and municipal engineering contracting, including consulting, design, research and development, supervision, project planning, equipment, construction, installation and technical services etc.
- Q: 1, common measurement and control cabinet, what is the common measurement and control cabinet? What signals are measured? High voltage side (10kV and above) have the corresponding relay protection device, regardless of the panel or on the spot, will not be on the public measurement and control cabinet; the so-called public measurement and control cabinet is measuring what? Low voltage measurement and control? Or what, for example, thank you (power generation, power supply and distribution does not matter, can speak on the line)2, network equipment cabinet, I probably can understand, is from the equipment from various communication signals collected by the communication management unit, the output signal of Ethernet, this cabinet is the main communication management machine and switch is?3, how to locate the remote communication cabinets? What is the main role? What are the main equipment?4, why do we usually need GPS time device, what is the significance? What will happen if there is no?
- The GPS device is used to synchronize the time of each station in the station, if the time is not synchronized when the failure of the failure of the failure of the report to see the action of each device has a relationship
- Q: On the safety hazards of electric equipment safety
- 3 where in the overhead power line protection zone new, reconstruction or expansion of the building, must go to the power supply department for the approval of the relevant procedures for the safety of power facilities construction. It is forbidden to borrow, dig fish ponds, pile up or dump harmful chemicals in the power line protection zones.4 where the demolition, the power line protection zones of overweight, lifting, drilling, piling, scaffolding and other construction work, it shall be permitted by the power supply departments, take appropriate safety measures, and can work in the power supply department under the supervision of professional staff.
- Q: Reactive power compensation methods commonly used in power equipment
- Hello!Electrical equipment commonly used in reactive power compensation and the method of improving power factor are: synchronous motor, synchro, series capacitor compensation, shunt capacitor and series reactor compensation (EHV transmission line) and SVC, SVG compensation. SVG is through the power electronic device IGBT and its control circuit, a active VaR of equal amplitude and opposite to the size of the system, the reactive power compensation device for reactive power compensation to offset the system in recent years is the development direction of reactive power compensation.
- Q: Power test equipment sales to find power supply company which departments? Which departments of the power supply company will use the power test equipment?
- What kind of power test equipment are you in charge of? Our unit is divided into the experimental class and the automation experiment class
- Q: What is the redundancy of electrical equipment
- Disk duplex: a I/O controller is added to the mirrored disk to form a dual disk to improve bus contention.RAID: cheap redundant array of disks (Redundant array of inexpensive disks). As the name suggests, it consists of a number of disks, through a controller to coordinate the movement of a single data flow into the disk. The RAID3 system consists of 5 disks, in which 4 disks store data, and the 1 stores the check information. If a disk fails, you can replace the disk on the line, and through the other 3 disks and check the disk to re create the data on the new site. RAID5 will check the information distributed on 5 disks, so you can replace any disk, the rest with the same RAID3.
- Q: What is the meaning of the high - voltage high - voltage device in power system, which is mainly used to protect the situation,
- That response to the power parameters is high frequency, this requires high cycle splitting device, tripping the corresponding circuit breaker, to remove the part of power grid connected or separated from the original into two or more power, get rid of the accident or the narrow scope of the accident to
Send your message to us
Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 50 set
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches