• Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V System 1
  • Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V System 2
Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
50 set
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Structure of  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

The CXF series of vertical axis maglev wind turbines undergoes a continuous improvement process, which incorporates exterior design, utility design, electrical engineering, dynamic engineering, power mechanics, aviation air engineering, wind tunnel testing, lightening protection, computer simulation techniques and other multiple specialities. Under the light theory of magnetic levitation technology, fan motor will be rotated by wind power without any mechanical friction.  Since the generator has no lubricant and no gear, the Magleve wind turbine are high-performance power generation, smooth operation, which is a milestone for a new age of power technology.

 

 

2. Main Features of Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

* Ideal for both of residential and commercial applications as well as off grid and on grid power systems.

* The unit provides a durable, reliable, and fully customized hybrid solution to Telecoms Base Receiver Station (BTS), Charging Station by Solar and wind  and also very suitable for power supply to home

* Intelligent control system with active protective functions

* automatically lower rotational speed during strong winds

 

3.Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Specifications:

 

tems

CXF600

Rated power

600W

Dimension (Height/Diameter)

Ø1540mm / 1320mm

Weight

50 kg

Blade material

Aluminum Alloy

Blade quantity

7 (3 Darrieusand 4 Savonius)

Swept area ㎡

0.30

Min starting wind speed

1.3 m/s

Cut-in wind speed

3.5m/s

Rated wind speed

13m/s

Cut-off wind speed

15m/s

Survival wind speed

60m/s

Generator type

AC,3Phases

Controller Output Voltage

24V/48V

Controller Braking System

3-phase short circuit by NFB brake

Ambient Temperature

-40~50 ℃

Noise

Less than 40dB

Annual Energy Production                 (@ 5 m/s wind speed )

about 1500 kWh

 

 

 4.  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Images

Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

5. FAQ

 

  1. Why to choose vertical axis maglev wind turbine ?

Re: You can find the answer in the following table

Comparison between HAWT AND MVAWT

Item

Horizontal axis wind turbine (HAWT)

Maglev vertical axis wind turbine (MVAWT)

Starting wind speed

High(≥3m/s)

Low(1m/s)

Wind conditions required

Require stable wind direction

Any wind direction

Encountered turbulence

Efficiency is reduce

Efficiency is not affected

Power stability

Changing by wind direction

Without any wind effect

Noise

Large (More than 45dB)

Low noise of less than 40dB  thank to maglev frictionless technology                        

Product appearance

Ordinary

Beautiful

Installation height

High (need to avoid the terrain turbulence)

Low (not influenced by  turbulence)

Installation location

Open area like suburb

Any locations

Generator material

Plastic or composite

metal

Structure strength

Poor (easy to broken)

High(double strengthen arm)

Resistance of wind speed

Poor(about 40 m/s)

High

 

2. Is it hard to install the wind turbine?

Re: System can be assembled in under an hour , without any welding; and ingle or multiple unit connections for greater energy generation. In addition, it is easy for connection with PV systems





Q: What are the main interference sources of the two power system
Power system electromagnetic environment consists of one or two devices, of which there are a variety of electromagnetic disturbance and interaction, the current electric power system is developing towards higher voltage, higher capacity, power network is more intensive and more complex systems, more advanced equipment to the direction of development, to guide electromagnetic disturbance of power system more serious and complicated. On the other hand, the advanced power systems using more advanced automation and other electronic and computer control, measurement, communication and protection system, and solid state electronic based advanced equipment and system tolerance electromagnetic disturbance ability is weaker, more susceptible to electromagnetic environment.
Q: What are the relevant national standards for power equipment?
The standard is very thin do not know what you want to give you some of the specific power of the main reference
Q: 1, what are the fire hazards caused by electricity in the server room?2 what are the fire hazards in the server room?
Three, should be based on the size of the project need to determine the location of the fire to determine the use of independent electric detector or non independent detectorFour, according to the specific circumstances of the electrical equipment to determine the electrical fire monitoring detector form and installation location
Q: How to solve the short circuit of emergency communication equipment
As you can see (xxxxx). But in the national disaster or war, the government can expropriate these hand car car.Thank you! I hope my reply will satisfy you!
Q: How to strengthen the management of electric power information communication equipment
As an important infrastructure in the process of automation and management modernization of China's power grid dispatching, the high efficiency and scientific performance of power information communication equipment can effectively promote the safe operation of power grid.
Q: 1, common measurement and control cabinet, what is the common measurement and control cabinet? What signals are measured? High voltage side (10kV and above) have the corresponding relay protection device, regardless of the panel or on the spot, will not be on the public measurement and control cabinet; the so-called public measurement and control cabinet is measuring what? Low voltage measurement and control? Or what, for example, thank you (power generation, power supply and distribution does not matter, can speak on the line)2, network equipment cabinet, I probably can understand, is from the equipment from various communication signals collected by the communication management unit, the output signal of Ethernet, this cabinet is the main communication management machine and switch is?3, how to locate the remote communication cabinets? What is the main role? What are the main equipment?4, why do we usually need GPS time device, what is the significance? What will happen if there is no?
The network equipment and the remote communication cabinet are responsible for the communication between the equipment and the background in the station and the communication with the electric power department
Q: What are the customer groups faced by power intelligent equipment?Products such as electric capacitor reactive power control (capacitor module), reactive power compensation controller, the series of electric power meter, active filtering equipment, power monitoring system, energy management system, operating system and DC power system accessory products.
If the capacitor is connected in series on the line, the line reactance is compensated and the parameters of the circuit are changed. Series compensation can reduce the loss of line voltage, improve the terminal voltage level, reduce the power loss and power loss, and improve the transmission capability.4 power capacitors include phase shifting capacitors, electric heating capacitors, voltage equalizing capacitors, coupling capacitors, pulse capacitors, etc.. Phase shifting capacitor is mainly used for compensating reactive power to improve the power factor of the system; the electrothermal capacitor is used to improve the power factor of intermediate frequency power system; equalizing capacitor in parallel with the general circuit breaker on fracture pressure; coupling capacitor is mainly used in electric power communication, measurement, control and protection of transmission line the capacitor is used for pulse; pulse circuit and DC high voltage rectifier filter.
Q: I would like to open a company on the construction of power equipment, what needs to be prepared? (including qualification level, capital requirements, etc.) the more detailed the better
First, the qualification of electric power project construction. Divided into one to four, respectively, by the Ministry of housing, the provincial housing department, the Municipal Housing Construction Bureau and County Housing Construction Bureau approval. Construction quality is also subdivided into general contracting, professional construction contract, etc.. The project general contracting, according to whether the design, supervision, equipment procurement and other business content, but also can be subdivided.
Q: How to run a company that operates electric equipment
Look for people who want to use the electrical equipment, such as the operator of the power station,
Q: Power equipment is required to replace the dimension, the state has no relevant provisions
This depends on the provisions of the local power supply department, generally not mandatory requirements.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches