• Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V System 1
  • Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V System 2
Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
50 set
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Structure of  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

The CXF series of vertical axis maglev wind turbines undergoes a continuous improvement process, which incorporates exterior design, utility design, electrical engineering, dynamic engineering, power mechanics, aviation air engineering, wind tunnel testing, lightening protection, computer simulation techniques and other multiple specialities. Under the light theory of magnetic levitation technology, fan motor will be rotated by wind power without any mechanical friction.  Since the generator has no lubricant and no gear, the Magleve wind turbine are high-performance power generation, smooth operation, which is a milestone for a new age of power technology.

 

 

2. Main Features of Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

* Ideal for both of residential and commercial applications as well as off grid and on grid power systems.

* The unit provides a durable, reliable, and fully customized hybrid solution to Telecoms Base Receiver Station (BTS), Charging Station by Solar and wind  and also very suitable for power supply to home

* Intelligent control system with active protective functions

* automatically lower rotational speed during strong winds

 

3.Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Specifications:

 

tems

CXF600

Rated power

600W

Dimension (Height/Diameter)

Ø1540mm / 1320mm

Weight

50 kg

Blade material

Aluminum Alloy

Blade quantity

7 (3 Darrieusand 4 Savonius)

Swept area ㎡

0.30

Min starting wind speed

1.3 m/s

Cut-in wind speed

3.5m/s

Rated wind speed

13m/s

Cut-off wind speed

15m/s

Survival wind speed

60m/s

Generator type

AC,3Phases

Controller Output Voltage

24V/48V

Controller Braking System

3-phase short circuit by NFB brake

Ambient Temperature

-40~50 ℃

Noise

Less than 40dB

Annual Energy Production                 (@ 5 m/s wind speed )

about 1500 kWh

 

 

 4.  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Images

Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

5. FAQ

 

  1. Why to choose vertical axis maglev wind turbine ?

Re: You can find the answer in the following table

Comparison between HAWT AND MVAWT

Item

Horizontal axis wind turbine (HAWT)

Maglev vertical axis wind turbine (MVAWT)

Starting wind speed

High(≥3m/s)

Low(1m/s)

Wind conditions required

Require stable wind direction

Any wind direction

Encountered turbulence

Efficiency is reduce

Efficiency is not affected

Power stability

Changing by wind direction

Without any wind effect

Noise

Large (More than 45dB)

Low noise of less than 40dB  thank to maglev frictionless technology                        

Product appearance

Ordinary

Beautiful

Installation height

High (need to avoid the terrain turbulence)

Low (not influenced by  turbulence)

Installation location

Open area like suburb

Any locations

Generator material

Plastic or composite

metal

Structure strength

Poor (easy to broken)

High(double strengthen arm)

Resistance of wind speed

Poor(about 40 m/s)

High

 

2. Is it hard to install the wind turbine?

Re: System can be assembled in under an hour , without any welding; and ingle or multiple unit connections for greater energy generation. In addition, it is easy for connection with PV systems





Q: 1, what are the fire hazards caused by electricity in the server room?2 what are the fire hazards in the server room?
Five, fire control room and electrical fire monitoring detector set over 8 independent electricFire monitoring detector six, electrical fire monitoring system settings should affect the power supply system
Q: The production and transportation process of electric power
The equipment of the two system comprises a measuring device, a control device, a relay protection device, an automatic control device, a DC system and necessary auxiliary equipment. Power system voltage level has 220V, 380V (0.4 kV), 3 kV, 6 kV, 10 kV, 20 kV, 35 kV, 66 kV, 110 kV, 220 kV, 330 kV, 500 kV, 750kV, 1000kV. With the improvement of motor manufacturing process, 10 kV motor has been mass production, so the use of kV, 6 kV has been less than 20 kV, 66 kV is also rarely used. The power supply system is 10 kV and 35 kV. Transmission and distribution system to 110 kV or above. Power plant generator has 6 kV, 10 kV and, with a total of 20 kV, users are 220V, 380V (0.4 kV) low voltage system 20kV.
Q: In what way is it confirmed that the destroyer is an electrical device? Identification or what.
Not yet installed agricultural low-voltage lighting circuit, not in the use of electrical equipment. Even if the person who took part in the erection of the wire, it will not cause harm to public safety, its behavior should be qualitative theft.
Q: How to strengthen the management of electric power information communication equipment
2 equipment based information is not complete. In the past is mainly due to the importance of equipment installation and use of the process to ignore the basic data, no serious equipment complete basic data collection and sorting, resulting in a lack of power information communication equipment basic information.3 equipment inspection is not in place. Regular inspection of power communication equipment can clear the health status of the equipment, and can detect the problems or defects in the equipment. At present, the problems existing in the inspection work of the electric power communication equipment are as follows: (1) there is not a reasonable equipment inspection cycle. (2) in the process of inspection and inspection of the equipment does not follow a certain inspection process. (3) during the inspection process, the equipment running state inspection is ignored, and the inspection of the equipment room condition, water proof and fire prevention ability is ignored. (4) the inspection of the sanitation and environmental temperature of power communication equipment is ignored.
Q: Part of the rated voltage of the power equipment is marked 10.5kv, and this is similar to the label 10KV power equipment what is the difference?Consulted a lot of teachers, but it is said that this is the old and new two methods, I would like to ask what is the basis of this, it is best to have a national standard for reference
3, rated voltage transformerRegulations, to accept the power of the primary winding, the output power of the two windings, the general, the primary winding voltage = network voltage, the voltage of the two winding due to the consideration of the loss, higher than the network voltage of 5% to 10%
Q: Private enterprises must be free transfer of power facilities
The new user electrical facilities investment, after the investment asset is transferred to the power supply enterprise, according to the need for "business rules", the actual state of electricity contribution, interface division, maintenance management ability, after consultation by both parties to determine.
Q: What are the effects of frequency variation on power users and power systems?
Influence of frequency variation on power users and power systems:There is a close relationship between the frequency of power equipment and the operation of power system
Q: Power equipment Market Overview
2013 first quarter, China's economy did not continue to stabilize the situation in the second half of 2012 rebounded, GDP grew by 7.7%, compared with the previous year's 4 quarter fell by 0.2 percentage points, lower than previously expected levels. The slowdown in economic growth driven by the demand for electricity consumption growth decreased synchronously, a quarter of the total electricity consumption growth rate year-on-year decline, the overall balance of the country's electricity supply and demand, in this situation, the national power investment continued to decline, a quarter of the country's main power generation enterprise project investment 61 billion 800 million yuan, down 17.1% over the previous year.
Q: For example, EPS emergency power supply and so on, as well as those used in public emergencies.
High / low voltage switchgear, power distribution cabinets, industrial ovens, constant temperature and humidity test box, ovens, air curtain machine (invisible door), inductive automatic door, air conditioning and industrial fans, NELL thyristor module, thyristor, single / three-phase bridge rectifier, fast recovery module
Q: In power system, the general conditions for the selection of electrical equipment are
Suitable voltage rating, suitable for workplace and environment, necessary protection

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches