• Large UPS GP9335C 120-160KVA System 1
Large UPS GP9335C 120-160KVA

Large UPS GP9335C 120-160KVA

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
2 Units pc
Supply Capability:
60 Units per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications: 

Model

GP9335C

Rectifier Type

6p

12p

6p

12p

6p

12p

6p

12p

6p

12p

Rated Nominal

120KVA/108KW

160KVA/144KVA

200KVA/180KW

300KVA/270KW

400KVA/360KW

Rated input voltage

380/400/415VAC 3-phase 4-wire

Rated frequency

50/60HZ

Input parameters 

Input voltage range

±25%

Input frequency range

45Hz~65Hz

Input soft start function

0-100%   5-300settable

Input power factor

>0.98(If harmonic filter is added)

Input harmonic current (THDi)

‹4.5%(If harmonic filter is added) 

Bypass 

Bypass voltage range

-20%~+15%

Bypass frequency range

50/60HZ±10%

Output parameters 

Inverter output voltage

380/400/415VAC 3-phase 4-wire

Voltage stability

±1%(Steady status),±3%(Transient status)

Frequency

50/60Hz

   Mains power synchronization window

±5%

Actually measured frequency accuracy (internal clock)

50/60Hz±0.01Hz

Output power factor

0.9(Output 90kW per 100kVA)

Transient response time

<5ms

Inverter overload capability

At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s

 

Short circuit current from inverter

3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds

Maximum Bypass capability

1000% for 100ms

 

Phase shift

characteristic

With 100% balanced load

<1°

With 100% imbalance load

<1°

 

Total harmonic

Distortion(THDv)

100% linear load

<1%

100% non-linear load

<3%

System efficiency (full load)

Up to 94% (inverter efficiency is up to 98%)

Rectifier output parameters

Charger output voltage stability

1%

DC ripple voltage

≤1%

Operating environment 

Operating temperature range

0~40°C

Storage temperature

-25~70°C(Without battery)

Relative humidity

0~95% No condensation

Noise (1m)

58-68dB

Protection level

IP20

Standard

Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3

 

Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q: Why should lighting transformers be used in factories and mines?
But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q: The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
Q: Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Q: Power and lighting transformers, lighting quality will be affected much?
Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords