Specifications

1.high quality pump
2.High pressure water pump
3.We are the manufacturer

Technology Parameter:
MODELRated flowRated HeadRated PowerRated SpeedRated voltageGWPipe sizeUnited Size
m3/hMeterKWR/MINvKGMMMM
WQD10-8-0.551080.552820220/380v1951435x250x120
WQD10-12-0.7510120.7520470x215x275
WQD8-16-1.110161.123520x260x260
WQ15-15-1.510151.525520x260x260

 

Specifications

1. Low noise
2. High quality
3. Competitive price
4. Operation Simple
5. 100% Cooper Wire

Application

WQD series dirty water pump is designed for dirty water,it can be widely used in
industry,mine,agriculture,environment protection, building construction, such as drainage slurry,mortar,waste water,and sewage ,paper scraps,
mud and sand and other solid particles.
It is also an ideal equipment for irrigation.
Operating limits

medium temperature+40°C
ambient temperature+40°C
Submersible depth:5m
pressure: 6 bar

Material and working limits

Pump body: Cast iron
Motor housing: Cast iron
Impeller: Cast iron
Motor wire:copper
Shaft: 45#steel
Insulation class: F
Protection class: IP68

Packing & Delivery

Packing: 1 pc/ctn
Packing design: standard export carton or customer's design
Delivery: 30 days after receiving deposit
Delivery port: Ningbo

Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
A standard atmospheric pressure can be 10.33 meters to 30 meters of water, suction is atmospheric pressure there are three standard atmospheric pressure so high? This is impossible in general, remove the vaporization removed 0.5 meters critical yo,
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q: How is the pump level of submersible sewage pump determined?
Below the top elevation of the sump, 200 is the warning water levelBut note: 1, the effective volume of the sump meets the requirements. 2, the pump should have enough submerged water level
Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
Q: What are the conditions required for hydraulic pumps to complete oil absorption and compression?
2, the change of working volume is periodic, and in each cycle, the oil absorption process is changed from small to big, and the process of oil pressure is changed from large to small;3, suction oil cavity must be separated from each other without interference.
Q: Filter backwash pump for what use, what is the principle of work ah?
When the filter is in normal operation, the impurity will be trapped in the upstream of the filter (filter medium). As the accumulation of impurities, the filter media will be blocked, and the direct performance is that the circulation will decrease. Usually, when the flow drops to a set point (the industry is usually judged by the pressure drop),
Q: What does "dual purpose" of water pump mean? Please expert advice
1, if the water pump in the process of a strong vibration, then must stop to check what is the cause, otherwise it will cause damage to the water pump.3, when the pump valve Water Leakage, some people will fill with dry soil to the water pump inlet pipe, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started to work, these dry soil will enter the pump, then it will damage the pump impeller and bearings, thus shortening the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that need to replace the new.
Q: What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q: Significance of water pump model ISO50-160
A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance parameters include flow, suction, lift, shaft power, water power, efficiency and so on;