High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD

High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Energy-saving Solutions for Enterprise
1
Program Overview
Saving energy achieves 10% -70%
The enterprises do not need to pay for expense of equipment manufacture and installation.
Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)
Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1
)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility
2
)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3
)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4
)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5
)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2
Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3
Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q: A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
The upper limit frequency transferred to 25HZ, the number of poles changed to 2, try to run when the motor speed test
Q: Can different brands of laptop power adapters be generic?
1, strictly speaking, different brands of laptop power adapter is not common. Even if the logo on the voltage and current are the same should not be mixed, will cause the power interface or motherboard failure or even damage. 2, with the same brand of different models of the power can be used temporarily, but should not be used for too long. 3, the cottage power adapter is best not to buy the use of hidden dangers, including spontaneous combustion and explosion, try to use the original power adapter.
Q: 2 pole 0.75 kW motor can increase the speed through the inverter?
if the 4-pole motor to rise to 2-pole motor frequency, The frequency of the motor rises to about 100 Hz, which is easy to implement for the frequency converter.
Q: If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
Motor brand above all, the general number of wrong is the inverter shows the speed is not right, for the speed control requirements are not high places will not be a problem, you can use
Q: ASUS power adapter Acer can use it
3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.) If it is for DELL and HP / Compaq and other notebook power adapter, will involve a decoding problem. Please pay attention when the pro to buy. Acer and Asus are not yet available. It is said that the market is also very popular universal adapter, a friend bought a LVSUN brand universal adapter LS-PAB90-BC10, with eight joints. Adapter has a liquid crystal display, you can also automatically switch the voltage, very smart, with more than a year, has also been used.
Q: How does the variable frequency motor output torque at very low frequencies?
50hz the following frequency, u constant, current and frequency is proportional to the frequency down the output current is also down, and torque and current is proportional to the natural torque is small
Q: Octopus AC Servo motor can be driven with ordinary inverter?
If it is asynchronous motor, then take the power, voltage matching ordinary inverter drive no problem, you only need to enter the appropriate parameters, such as current, power size and other parameters, and then off-line parameters from the adjustment (if the vector control run), you can run
Q: Do you need to rectify before switching?
I used to do the frequency of the words to be rectified
Q: Laptop power adapter is used to do what
Simply put the transfer into DC China's electricity is 220V AC, and the notebook is a direct current, the need for adapter to rectify, filter, regulator, and finally we need to form a direct current
Q: Will the laptop's power adapter is not the original good?
See the adapter is suitable for notebook models to use, the following three conditions for reference: 1. The output voltage of the adapter is the same as that of the notebook. 2. Is the adapter's output current consistent with the notebook's requirements? (Or a little bit of the current is also not.) 3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.)