• High Medium Voltage Drive 10KV 4000KW RMVC4000-A100/5000 VFD System 1
  • High Medium Voltage Drive 10KV 4000KW RMVC4000-A100/5000 VFD System 2
High Medium Voltage Drive 10KV 4000KW RMVC4000-A100/5000 VFD

High Medium Voltage Drive 10KV 4000KW RMVC4000-A100/5000 VFD

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Energy-saving Solutions for Enterprise
1
Program Overview
Saving energy achieves 10% -70%
The enterprises do not need to pay for expense of equipment manufacture and installation.
Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)
Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1
)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility
2
)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3
)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4
)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5
)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2
Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3
Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
can use. But in the inverter "motor parameters" to be some changes. Such as the number of poles, rated current.
Q: Is the laptop power adapter high temperature normal? Is there anything else?
Normal, my power adapter is also very hot, generally ignore
Q: In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is no load, the demolition of the gearbox is the same can be run.
Q: 380V motor addition to the inverter, but also how to change its speed?
Rotary motor rotor series resistance adjustable speed. 4. Change the slip electromagnetic speed (slip motor)
Q: Can the inverter stop intermittently during operation? If so, how to connect and set up
Look at your inverter manual, because the inverter is not a simple wiring can run, first of all have to know that a few are external terminals (inverter input terminals),
Q: What is the motor series parameter setting of the inverter? If it is with the spindle,
The number of motor poles can be estimated by the parameters: 1000Hz corresponds to 60000rpm, According to "Speed in rpm = 60 * Frequency in Hz / (Number of Poles / 2)", Number of poles = 60 * Frequency indicated by Hz * 2 / Speed in rpm = 60 * 1000 * 2/60000 = 2 poles. The same is true with 333Hz and 20000rpm projections. The number of motor poles for the frequency converter should be entered with the number of poles of the motor that are directly connected to the frequency converter.
Q: Do you want to pay attention to the number of poles of the motor when selecting the inverter?
Inverter is generally selected by the power, do not consider the number of poles, but the inverter output current is controlled by the module, so you can choose in the selection as much as possible in accordance with the rated current to select the inverter. And left redundant party B overload and other phenomena.
Q: Which machines are used for the frequency converter
Used on a motor that needs to change the speed to change the power.
Q: What is the frequency converter used to do, why some motor with the inverter?
Frequency converter is widely used in the speed regulation of AC motor.Varameter speed control technology is an important development direction of modern power transmission technology, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious.
Q: Speed of 3000 r / min three-phase motor how to change its speed
Voltage regulator, variable pole speed, the best inverter speed. The

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches