• Fuji Electric Servo Motor Model EW100EAG Standard Products System 1
  • Fuji Electric Servo Motor Model EW100EAG Standard Products System 2
  • Fuji Electric Servo Motor Model EW100EAG Standard Products System 3
  • Fuji Electric Servo Motor Model EW100EAG Standard Products System 4
  • Fuji Electric Servo Motor Model EW100EAG Standard Products System 5
Fuji Electric Servo Motor Model EW100EAG Standard Products

Fuji Electric Servo Motor Model EW100EAG Standard Products

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1 kg
Supply Capability:
3200 kg/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

New leakage circuit breaker


Ew32 type ew63 type ew125 type ew160 type ew250 type ew400 type ew630 type
EW800 type
Ew50 type ew100 type


Ew32 and ew50 (standard products)
Basic models: ew32aag-2p, ew32aag-3p, ew32eag-3p
Rated current a (code): 5 (005), 10 (010), 15 (015), 20 (020), 32 (032)
Reaction current MA (code): 15 (a), 30 (b), 100 (c)


Basic models: ew50aag-2p, ew50aag-3p, ew50eag-3p
Rated current a (code): 5 (005) 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50
(050)
Reaction current MA (code): 15 (a), 30 (b), 100 (c)
Note: ew50eag-3p reaction current MA (code): 15 (a) 30 (b) 100 / 200 switching
(k)
Basic model: ew32sag-3p
Rated current a (code): 3 (003) 5 (005) 10 (010) 15 (015) 20 (020) 32 (032)
Basic model: ew50sag-3p
Rated current a (code): 5 (005) 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50
(050)
Basic model: ew50rag-3p
Rated current a (code): 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50 (050)
Reaction current MA (code): 30 (b), 100 / 200 / 500 switching (k)


Ew63 and ew100 (standard products)
Basic model: ew63eag-3p
Rated current a (code): 63 (063)
Sensitivity current MA (code): 15 (a) 30 (b) 100 / 200 switching (k)


Basic model: ew63sag-3p, ew63rag-3p
Rated current a (code): 63 (063)
Sensitivity current MA (code): 30 (b), 100 / 200 / 500 switching (k)


Basic model: ew100aag-3p
Rated current a (code): 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b) 100 / 200 switching (k)


Basic model: ew100eag-2p
Rated current a (code): 50 (050) 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b), 100 / 200 switching (k)


Basic model: ew100eag-3p
Rated current a (code): 50 (050) 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b), 100 / 200 / 500 switching (k)


Ew125 (standard product)
Basic models: ew125jagc-3p, ew125jagc-4p, ew125sagc-3p, ew125sagc-4p,
ew125ragc-3p, ew125ragc-4p
Rated current a (code): 15 (015) 20 (020) 32 (032) 40 (040) 50 (050) 63 (063)
75 (075) 100 (100) 125 (125)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (k)



Ew160 (standard product)
Basic models: ew160eagc-3p, ew160jagc-3p, ew160jagc-4p, ew160sagc-3p,
ew160sagc-4p, ew160ragc-
3P,EW160RAGC-4P
Rated current a (code): 125 (125) 150 (150) 160 (160)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew250 (standard product)
Basic models: ew250eagc-3p, ew250jagc-3p, ew250sagc-3p, ew250ragc-3p
Rated current a (code): 175 (175) 200 (200) 225 (225) 250 (250)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Basic models: ew250jagc-4p, ew250sagc-4p, ew250ragc-4p
Rated current a (code): 175 (175) 200 (200) 225 (225)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew400 (standard product)
Basic models: ew400eagc-3p, ew400sagc-3p, ew400ragc-3p, ew400ragc-4p,
ew400hagc-3p, ew400hagc-4p
Rated current a (code): 250 (250) 300 (300) 350 (350) 400 (400)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew600 (standard product)
Basic models: ew630eagc-3p, ew630ragc-3p, ew630hagc-3p
Rated current a (code): 500 (500), 630 (630)
Reaction current MA (Code: 100 / 300 / 500 / 1000 switching (J)


EW800 (standard product)
Basic models: ew800eagc-3p, ew800ragc-3p, ew800hagc-3p
Rated current a (code): 700 (700) 800 (800)
Reaction current MA (Code: 100 / 300 / 500 / 1000 switching (J)


New leakage circuit breaker


Ew32 type ew63 type ew125 type ew160 type ew250 type ew400 type ew630 type
EW800 type
Ew50 type ew100 type


Ew32 and ew50 (standard products)
Basic models: ew32aag-2p, ew32aag-3p, ew32eag-3p
Rated current a (code): 5 (005), 10 (010), 15 (015), 20 (020), 32 (032)
Reaction current MA (code): 15 (a), 30 (b), 100 (c)


Basic models: ew50aag-2p, ew50aag-3p, ew50eag-3p
Rated current a (code): 5 (005) 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50
(050)
Reaction current MA (code): 15 (a), 30 (b), 100 (c)
Note: ew50eag-3p reaction current MA (code): 15 (a) 30 (b) 100 / 200 switching
(k)
Basic model: ew32sag-3p
Rated current a (code): 3 (003) 5 (005) 10 (010) 15 (015) 20 (020) 32 (032)
Basic model: ew50sag-3p
Rated current a (code): 5 (005) 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50
(050)
Basic model: ew50rag-3p
Rated current a (code): 10 (010) 15 (015) 20 (020) 32 (032) 40 (040) 50 (050)
Reaction current MA (code): 30 (b), 100 / 200 / 500 switching (k)



Ew63 and ew100 (standard products)
Basic model: ew63eag-3p
Rated current a (code): 63 (063)
Sensitivity current MA (code): 15 (a) 30 (b) 100 / 200 switching (k)


Basic model: ew63sag-3p, ew63rag-3p
Rated current a (code): 63 (063)
Sensitivity current MA (code): 30 (b), 100 / 200 / 500 switching (k)


Basic model: ew100aag-3p
Rated current a (code): 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b) 100 / 200 switching (k)


Basic model: ew100eag-2p
Rated current a (code): 50 (050) 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b), 100 / 200 switching (k)


Basic model: ew100eag-3p
Rated current a (code): 50 (050) 63 (063) 75 (075) 100 (100)
Sensitivity current MA (code): 30 (b), 100 / 200 / 500 switching (k)


Ew125 (standard product)
Basic models: ew125jagc-3p, ew125jagc-4p, ew125sagc-3p, ew125sagc-4p,
ew125ragc-3p, ew125ragc-4p
Rated current a (code): 15 (015) 20 (020) 32 (032) 40 (040) 50 (050) 63 (063)
75 (075) 100 (100) 125 (125)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (k)



Ew160 (standard product)
Basic models: ew160eagc-3p, ew160jagc-3p, ew160jagc-4p, ew160sagc-3p,
ew160sagc-4p, ew160ragc-
3P,EW160RAGC-4P
Rated current a (code): 125 (125) 150 (150) 160 (160)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew250 (standard product)
Basic models: ew250eagc-3p, ew250jagc-3p, ew250sagc-3p, ew250ragc-3p
Rated current a (code): 175 (175) 200 (200) 225 (225) 250 (250)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Basic models: ew250jagc-4p, ew250sagc-4p, ew250ragc-4p
Rated current a (code): 175 (175) 200 (200) 225 (225)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew400 (standard product)
Basic models: ew400eagc-3p, ew400sagc-3p, ew400ragc-3p, ew400ragc-4p,
ew400hagc-3p, ew400hagc-4p
Rated current a (code): 250 (250) 300 (300) 350 (350) 400 (400)
Reaction current MA (Code: 30 (b), 100 / 300 / 500 / 1000 switching (J)


Ew600 (standard product)
Basic models: ew630eagc-3p, ew630ragc-3p, ew630hagc-3p
Rated current a (code): 500 (500), 630 (630)
Reaction current MA (Code: 100 / 300 / 500 / 1000 switching (J)


EW800 (standard product)
Basic models: ew800eagc-3p, ew800ragc-3p, ew800hagc-3p
Rated current a (code): 700 (700) 800 (800)
Reaction current MA (Code: 100 / 300 / 500 / 1000 switching (J)

Q: A question for electriciansi am getting a bachelors degree in entertainment technology. The apprenticeship program is closed but i would like to get a head start for the next go around. Should i go to school and get a masters in electrical engineering or should i become a grunt and get the experience? orwhat do you guys think? I know local 3 is hard to get intovery hard???
If I have been hiring an electrician, i'd sidestep every person with a posh enterprise call, and that i'd probable leaf by using telephone e book in alphabetical order, so i'd propose something like Abbey electric powered centers (except you're blessed with a time-honored or surname that comes early interior the alphabet).
Q: I still don't know what course suits me. My father is suggesting me this degree. I'm just wondering what jobs could I get if I pursue this
a lot of them like;electrical engineer,powerstation manager,mine or plant engineer;works manager/engineer,resident engineer,engineering consultant
Q: For example a computer or a TV.
Yes!
Q: I am living in a state where there is lots of Electricity cut off in other words the Loadshedding.When I listen to radio on short wave and medium wave during no electricity ON in our town, it plays well and clear. But when electricity comes its totally inaudible because of too much noise like srrrrrrr, shrrrrrrr,trrrrrrrr. Means I have to turn my radio off. My question is what thing does this cause??
It is interference produced by electrical equipment such as motors, TVs, transformers, computers and fluorescent lamps. I guess your radio is battery operated. If you take it a mile or so outside the town, you will find you get good reception with no noises. I get this at home too. I find if I want to listen to short wave, I need to turn everything off, including fridge, TV and computer. You could try turning everything off in your house and see if it helps.
Q: I am trying to work with an opamp
McMaster-Carr is a good place for general electrical equipment
Q: HI I need to know if anyone knows the MN electrical code for how many can lights I am allowed on one circuit using 14-2 with 15amp. also I would like to put some in my soffit outside, any type of can required for this? Thanks.
Just keep the total load less than 80% of the circuit and you should be fine, even Dave Jacobson would not have a problem with that, he is a fun inspector to deal with, if you are borderline will depend on the inspector, if you are over it will not fly. In the 2008 code there is this nice little deal about all electrical equipment installed outdoors, has to be rated either for damp, or wet locations, even gfci outlets in an in use cover, and in a house have to be of the tamper resistant type . If you watch those things, even good old Dave won't have a problem with it, but I bet he still looks at every breaker in your panel, the label I mean Good luck.
Q: has to do with electrical control
It is the National Fire Protection Association standard for electrical safety. Just do a Yahoo search for nfpa 70 and you will find it.
Q: I just replaced a light fixture in an apartment complex.I discovered that the bonehead that did the install did not run an equiptment ground when he installed the entire circuit that the light is ran off of (dumb a**!!!!!!!!)Does anyone know if it would be up to code if I where to just drive an 8 ft. ground rod and ground the fixture/entire circuit off of the rod?I have looked everywhere.Cannot find anything in code books.If someone knows where this is in NEC, please include the location.Anybody have any input?
Driving a ground rod is not the answer. The circuit should be grounded at the panel. a lot of the older homes do not have a ground. Just hot Neutral. If you are just running a light fixture it will work with-out an equipment or earth ground,While it is a lot safer to have an earth ground.
Q: If I decide to choose electrical engineering as my college major what would I be doing on a regular basis for my job?
Shelly answered pretty well but there's sooooo many fields you can go into, ESPECIALLY if you get an education in Mechanical Engineering too. I'm going into Electrical Engineering at ECE Illinois, possibly the best school ever created. My (dream) career is working at the Department of Defense for the advancement of science and technology, hopefully more based towards making everyday life easier, alternative energy, and warfare. There are A LOT of careers you can get out of it, like shelly showed, but more. yeah, you just got excited didn't you?
Q: A company specializes in manufacturing electrical equipment. Recently, several long-time customers have complained about the quality of the equipment. It seems there are several damaged goods. The defective equipment should have been caught when the boxes were packed. The manager is wondering which of the three packers is not doing the job properly. Clerk 1 packs 40% of the boxes and usually has a 2% defective rate. Clerk 2 packs 30% with a 2.5% defective rate. Clerk 3 boxes 30% of the boxes and her defective rate is 1.5%. Which clerk is most likely responsible for the boxes that raised the complaints?
clerk 1; 0.4(0.020) 0.0080 clerk 2; 0.3(0.025) 0.0075 clerk 3; 0.3(0.015) 0.0045 answer: clerk 1

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches