• FSK Roofing Insulation Adhesive Heat Insulation Materials System 1
FSK Roofing Insulation Adhesive Heat Insulation Materials

FSK Roofing Insulation Adhesive Heat Insulation Materials

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Description:

FSK7180 is the most popular laminated thermal insulation sheeting for covering ducts and pipes wrapped up by a thermal insulator such as glass wool and rock wool, PU foam and other insulation to protect them against vapor moisture in order to work more effectively, includes an reflective aluminum sheet and a fiberglass network disposed on and over a surface of the aluminum sheet

2. Construction & Benefits:

Reflective Aluminum Foil Lined With Kraft and Reinforced by fiberglass from 3 directions make this products durable. This Kind of FSK have more fiberglass as Scrim. So that thisFSK 7180 have more strength than FSK 7160

Aluminum foil which is a good barrier to moisture, rust and the air, and friendly to environment, good conductivity from the aluminum layer eliminates the electrostatic effect easily as exposure and kraft being liner to rise the strength, they sandwiched together through polyethylene as adhesive.

l High performance cost ratio: reasonable price and professional service.

l Environment friendly: it does not contain any hazardous or harmful materials.

l Convenient to use, easy to be folded into various shapes according to actual needs.

l Better resistance and tenacity according to glass fiber within.

l Reduces heat loss in winter, heat gain in summer.  

l Not effected by moisture and humidity.

l No special handling or breathing protection required.

3. Application:

It could be used as reflection, packing paper, moisture proof, radiant barrier and easy to fold as your need.

1. As a heat insulation materials in car, train, roof and wall, also been attached to glass wool blanket, rock wool board, mineral wool for get better performance.

2. A laminated thermal insulation sheeting. for covering ducts and pipes wrapped up by a thermal insulator such as glass wool and rock wool, PU foam and other insulation to protect them against vapor moisture in order to work more effectively.

3. As a sound absorber in KTV room, cinema, opera house, factory and other building.(only indicates 7160P, 7150P)

4. Package of industrial products and other place that you want to use.

4. Dimension/Size

(1) Roll width: 1000mm, 1200mm and 1250mm

(2) Roll Length: 50m, 100m, 200m, 500m, 1000m, or upon request.

(3) Core I. D.: 3"(76mm+/-1)

5. Similar products & guide

(1) DFC1001: Double sided aluminum foil supply better perfomance and function.

(2) FSK7160-P, perforate the FSK7160 as to absorb acoustic

Q: How do I find roofers who are specialised in protection against invaders from outer space. I called 10 and they said they would call me back, but no one did so far. It must be really complicated.
yes it does, only if aliens truly existed have you ever stopped to think that some of these strange flying objects maybe be a VERY TOP SECRET military project, the goverment might be paying millions to the media and people so that they assume its from outer space so that their projects remain secret
Q: Should a two story home have insulation under the roof in the big closets ?
yea. it might cost you some to put it in but it will save you a lot in the future with heating and air conditioning bills
Q: I know you're not supposed to directly insulate the roof due to the roof getting super heated in the summer, but my walk-in (actually, more like "crawl in") attic is very hot in the summer and very cold in the winter. Is there anything I can do to improve efficiency? I can't help but think I'm wasting a lot of energy just to keep my roof lasting a little longer.
You can avoid the condensation problem by simply leaving a minimum 2'' gap between the roof and the insulation. You need to fix battens on to the rafters ( at least 2'' from the tiles ) and then fix blanket or rigid insulation tight between them. The battens will maintain the air space. You then need to fix a vapour barrier over the whole thing and finish with plasterboard. No small job to do it properly ! ps you need to check the condition of the roof before you start and fix any loose tiles etc Alternatively, turn the heating up and wear a thicker sweater.
Q: I would like to find foam type tiles for my roof of decking, insulation?
www.okorder I checked the website I posted by searching 'foam roofing' on google. This link is what I found but there are others... Google it to find your best deal. I think I will spray this stuff under my pier and beam home just to insulate. Thanks for the tip! I can buy this product, apply it myself and cut the cost down to 1/3 or more.
Q: what effect does changing the pitch of a roof have on the insulation properties and durability of a roof?
The pitch of a roof has zero effect on the r-rating of insulation. Proper ventilation of the attic space, whether steep or low pitched, simply provides the optimum environment for the r-factor of the insulation to do its job more efficiently. Any attic, regardless of pitch, if it is not properly ventilated, would stress the effectiveness of any insulation product unnecessarily. The durability of the roof is not adversely affected either.
Q: Foam and the new building technolodgy's are coming to New Orleans. The rebuilding is causing New Orleans to be the "Greenest City in America". Energy Efficiency and the proper buiilding techniques tak hold.
foam is great but ugly as hell
Q: I'd like to put a train set in my loft / attic, so to avoid it being cold in there during the winter I'm considering having no insulation in the floor of it where one usually would, thus allowing the heat to rise into the loft. Then, insulate the roof between the rafters instead. Is this just as good at keeping the heating costs down?
only if you do it right.do you have plenty of head room if so drop the ceiling down and super insulate two feet or more and don't forget to leave air space between roof and top of insulation or your roofing boards will rot very quickly.
Q: I know when you inhale the insulation from the roof irritates the throat but what can you do to clear it from your throat after inhaling it?
it's not your throat you should be worried about. it's your lungs. wear a respirator....or at the very least, a dust mask. you only live once so make it last.
Q: we have liq. ammonia storage tank (capacity 40000 ton)having double wall & suspended deck.liq. NH3 stored at temp -33 degree cent. insulation (form ) being provided to annular space (wall ) but not on top roof . can you explain for exact reason.with regardsanvar shaikh
Insulation is less necessary on the roof. The ammonia is mostly a liquid, and a liquid would absorb heat rapidly from tank walls. Above the liquid is vapor, and vapor absorb heat much less rapidly than liquid does, so insulation is less important there.
Q: Finally remembering to do so, before my family and I left the house for approximately 4 hours, I turned off the heat before leaving. When we came home I turned it back on, but was shocked to see that the temperature had dropped 4 degrees in that time. 4 degrees in just under 4 hours seems like a lot of heat loss, does it not? I've seen the insulation in our roof and it's just that sawdust looking stuff spread everywhere. I feel like I'm paying a lot of unnecessary dollars for heating: the air does kick on every hour or two and we keep the thermostat at 68.Is it reasonable for me to talk to my landlord about this problem and getting better insulation in the ceiling, and maybe in the roof? (the master bedroom, on the far corner of the house, is always 2-3 degrees below the rest of the house). Are my expectations to not lose a degree of heat or more per hour unreasonable? Would a typical landlord consider this a problem worth discussing?
I never turn my heat or ac off when I leave the apartment. I'd say you can ask all you want but the landlord won't be listening to you. And I don't think 4 degree drop is a lot. And it does depend on what the weather outside is. If I had 68 degrees indoors I'd always have a cold. What is your monthly bill and which part of the country are you in? My bill is around $42 a month. I have insulated draperies, I use only one 40 watt bulb at my place. When it gets cold in here my 40 watt bulb will heat my place.