• Flange DN50 System 1
Flange DN50

Flange DN50

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Ton m.t.
Supply Capability:
3500 Tons per Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

dn50 flange

 

Certificate of CE, ISO9001

 

2 1.Size:1/16"-76".

 

3WT:SCH20,SCH40,SCH80.

 

4Stand of ANSI/ASME

 

The specification of   dn50 flange

 

 

item

 

 standard No.

 

 size

 

 PN

 

 Type

 

 Material

 

 1

 

 ANSI B16.5

 

 1/2"--24"

 

 150-2500LBS

 

 BL,SO,SW,LJ,WN,THD

 

A105,  A350LF2, A182 F11A182 F304/F304L,F316/F316L

 

 2

 

 LONG WN

 

 1/2"--24"

 

 150-2500LBS

 

 Long welding-neck

 

 A105, A350LF2,A182 F304/F304L,F316/F316L

 

 3

 

 ANSI B16.47 A(MSS SP-44)

 

 26"--60"

 

 150--900LBS

 

 BL,WN

 

 A105,  A350LF2, A694,A182 F304/F304L,F316/F316L

 

 4

 

 BS3293-1960 STANDARD

 

 26"--48"

 

 150-600LBS

 

 SO,WN

 

 A105, A350LF2,A182 F304/F304L,F316/F316L

 

 5

 

 ANSI B16.47 B(API605)

 

 26"--60"

 

 75--900LBS

 

 BL,WN

 

 A105,  A350LF2,A182 F304/F304L,F316/F316L

 

 6

 

 ASMEB16.36 STANDARD

 

 1"--24"

 

 300--2500LBS

 

 SO,WN,THD

 

 A105,  A350LF2,A182 F304/F304L,F316/F316L

 

 7

 

 AWWA C207

 

 4"--144"

 

 Class B,D,E,F T/1

 

 PL

 

 A105,A181 A36,

 

A516Gr.60,65,70

 

 8

 

 EN1092-1:20002 STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,

 

25,40,63,100

 

TYPE01,02,04,05,11,

 

12,13,21,32,33,34

 

 EN10025(S235JRG2),

 

EN10222-2AND3

 

(P245GH ANDP280GH),

 

EN10222-5(1.4303,1.4306,

 

1.4307,1.4401,1.4404,

 

1.4435,1.4541,1.4571)

 

A105/C21/1.0432 C22.8/

 

P150GH/1.0460

 

 9

 

 BS4504 SEC.3.1/1989 STANDARD

 

 NS15-2000

 

 PN2.5,6,10,16,

 

25,40

 

 CODE101,102,104,105,111,

 

112,113,121,132,133,134

 

 BS970 070M20 BS4360

 

GR.43A BS1503-164 GR.490

 

 BS 1503-224 GR.410

 

 BS 1503-304S11

 

304S31 321S31 316S31 316S11

 

 10

 

 BS10-1962 STANDARD

 

 NB10-3000

 

 TABLE D/ E /F/H/J

 

 SO THD BL WN

 

BS1501-161 GR.B AND C BS1633

 

GR.B BS 1503-240

 

GR.240 BS 1503-620 BS3604

 

 11

 

 ISO 7005-1 STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,20,

 

25,40,50,110,150,

 

260,420

 

 TYPE01,02,03,04,05,11,

 

12,13,14,15,21,32,33,34

 

 ISO2604-1 F8 F9 F13

 

 F18 F22 F49 F62 F46 F59

 

 12

 

 NFE29203 STANDARD

 

 DN10-600

 

 PN2.5,6,10,16,20,

 

25,40,50,100,150,

 

250,420

 

 TYPE01,02,03,04,05,11,12,

 

13,14,15,21,32,33,34,35

 

 NFE29204 BF 42 BF42N

 

BF48 BF48N

 

 13

 

 JIS B2220 STANDARD

 

 10A-1500A

 

 PN5K,10K,16K,

 

20K,30K

 

 SOP(PL) SOH(SO A B C ) WN

 

 JIS G3101 SS41

 

 JIS G3201 SF40A(S20C)

 

 AND SF45A(S25C) JIS G3202 SFVC1

 

AND SFVC 2A

 

 14

 

 DIN STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,25,

 

40,64,100,160

 

 SO,BL,PL,WN,LOOSE,THD

 

 RST37.2/1.0038/

 

DIN17100C22.8/1.0460

 

A105/C21/1.0432 1.430 

 

Q: How to distinguish the type of tubing joint?
The oil pipe connection depends on what standard. It is convenient for you to contact me. specializes in this thing.
Q: The other day I was pulled over for speeding. The ticket said I was going 50 mph in a 25 mph zone. I am sure I wasn't going nearly that fast and the officer didn't use any sort of radar technology to determine my speed but rather paced it on a very hilly, curvy road. I've read that when officers pace a car on a road like this it is likely to be more inaccurate. Also he only paced me for a couple seconds, while I was slowing down at a stop sign, so I doubt it would be accurate at all. Lastly, he didn't turn on his lights and pull me over until we were on a completly different street where the speed limit was 45 mph. I don't know if that would change anything but someone told me it might. Is there anyway I can fight this (because I know I wasn't going as fast as he said, and I believe the only reason my speed was bumped up to 50 was so I could get the higher fine ticket). Thanks for any help!
Yes. The ejector pump creates high head pressure when it kicks on. The vibration can also cause cracks. For the minor difference in cost why would you want to take the chance? Edit- First guys please READ the code book. Find the section that informs you that local codes if more restrictive can supercede state or national codes. Next wv EXACTLY where in his post did he use the term MACERATOR. Not all sewer pumps are macerators. The small lift pumps that come with the package systems put a very strong torque on the pipe when they turn on. This torque WILL break fittings. I also never use the rubber fernco style check valves that come with the pumps. The pressure rated glue joint type are the only way to go. Pump 30 gals of sewage into someones basement sometime. Then have them call me. I will do a proper installation. Don't quit your day job. ENJOY GUYS.
Q: ok- so if you smoke a whole lot of marijuana inside your house- i mean to a point where you smoked like 5 grams- can cops somehow detect it from the helicopters using their lil f*cking weed growing detectors- if you can detect weed growing then is it possible to detect if alot of weed has been smoked- this question has been in my mind for a while now
Bridgestone site for reviews and their winter tire u tube videos.
Q: I suck at this stuff. I have an F and grades close really soon.1. Potential energy is the energy of?2. Kinetic energy depends on?3. Gravitational potential energy depends on?4. 5 renewable resources and 5 nonrenewable resources.5. What kind of energy is stored in a stretched rubber band?6.At what point does a roller coaster have the greatest potential energy?Help if you can please. I'll answer any question you want if I can!!Thank you. (:
You forgot to to give us a picture of the crossword.
Q: Basically when my alarm goes off, I wake up in a haze, but am not aware enough to know I have to actually GET UP and go to work.Anyone have any tricks for actually getting up when the alarm goes off?
John, you're going to need to brake out some concrete around the stack to allow the bottom no-hub coupling to be partially below the slab. To make the cut on the cast iron below the slab, means you are going to need to brake out the entire 4 of concrete about 12 square (or round), remove the gravel and some dirt, just to get the tools in there to cut it. As a professional, I personally would just brake it out to make the connection below the slab, but it's your house and your call. The B-dry system typically consists of waterproofing panels on the walls and interior drain tile and a sump pump. So damaging the underslab drain tile is possible, but is also easily repaired if damaged. Good luck with the project
Q: what is elastomer?what is resin?
A picture would help. But if you are talking about a Bronze P-trap pipe being corroded then I think I can help. There are two options if all that is bad are the threads then you can cut that off the old P-trap and replace it with a P-trap that uses compression fittings. IF the Bronze P-trap pipe is too bad off usually you will find that there is also a large copper pipe it is soldered too. What I do is cut off the old Bronze P-trap at the copper piece. If you can, remove the Bronze piece from the copper pipe with a torch. I like to do this when possible but it is not mandatory. Clean up what ever you have left and use a compression replacement P-trap. I use PVC. They last longer. I can't see what you see so if this is not helpful then a picture would help us better answer this question.
Q: Please specify a bit, 10 finger tube diameter or outside diameter, screw thread is the pipe thread size, cone or cylindrical pipe thread?
The diameter of the pipe can be divided into outer diameter, inner diameter and nominal diameter.The pipe is a seamless steel pipe pipe diameter by the letter D to represent, then additional outer diameter size and thickness, such as diameter of seamless steel pipe 108, a wall thickness of 5MM, denoted by D108*5, is also used outside said, such as De63 plastic pipe, such as reinforced concrete pipe, cast iron pipe, galvanized steel pipe, said the DN, in the design drawings is generally used to represent the nominal diameter, nominal diameter is a standard in order to design and manufacture and maintenance convenient set artificially, with nominal diameter, tube (or pipe) specification name. The nominal diameter of a pipe is not the same as the inside diameter and the outside diameter of the pipe,
Q: Is the trachea connected directly to the inside and outside threads? I remember a sealing ring
Pipe joint with advanced structure, good performance, convenient use, no welding, no piping will flare and a series of advantages, therefore, sleeve type pipe coupling has been widely used in various types of machinery, hydraulic pneumatic system. But the card sleeve pipe joint is made of higher precision, because of the complex process, it should not be scattered or small batch manufacturing, need professional production.Joint is generally divided into two types, plastic joints and metal fittings, plastic joint production of low cost, simple manufacturing process, and the pressure is only 1 MPa, metal joint complex production process due to the use of the material requirements, so expensive, the high temperature resistant, metal fittings, some high requirements of the environment the preferred
Q: No strikes in neighborhood in over 30 yrs. Any thoughts.
Check with your local building code to see what they specify. In most areas you need to be licensed to make gas connections.
Q: PVC pipe joint leakage how to do?
Method for solving leakage of water pipe joint:The 1. pipe itself is broken and can only be replaced with a new one.2., the mouth of the water leakage can be removed, if there is no glue pad should be installed on the rubber pad, rubber pad aging, change a new, silk mouth painted white paint, and then wrapped on hemp silk after loading, with raw material belt winding is also the same.
Our high-quality products are widely used in petroleum, chemical, metallurgy, electric power, ship, natural gas, and pipeline industries. We have gained a good refutation among users. At the same time, our products are exported to Europe, the United States, the Middle East, Africa, and Southeast Asia, as well as other countries and regions.

1. Manufacturer Overview

Location Hebei,China
Year Established 2008
Annual Output Value US$10 Million - US$50 Million
Main Markets 15.00% North America
15.00% South America
15.00% Eastern Europe
15.00% Southeast Asia
15.00% Africa
15.00% Oceania
10.00% Mid East
Company Certifications ISO9001-2000;ISO9001-2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Tianjin
Export Percentage 91% - 100%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 10,000-30,000 square meters
No. of Production Lines 4
Contract Manufacturing
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords