Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
- The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
- Q: What are the ways of hydraulic pumps?
- Hydraulic pump is a power component of hydraulic system. It is driven by an engine or an electric motor. It draws oil from the hydraulic tank to form a component of the pressure oil which is sent to the actuating element.
- Q: Why can't the inlet of centrifugal pump be negative pressure?
- The entrance can be a negative pressure. You can often see someone pumping water from the pool. How can you pump water if it is not negative pressure?
- Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- (three) infusion limited number of pills produced after the dose of obstruction by infusion pump and specification of the matching test, will reach acceptable when the storage pressure of the pressure to determine the alarm blocking. Thus, some have restrictions on the infusion tube blocked after the maximum dose pill may have blocked the trigger before the alarm.
- Q: Harm of air pump and pump
- If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- What you should say here is the concrete pump.Ground pump: the pump will be placed in a position on the site, the pipeline will be sent to the construction of concrete surface,
- Q: Which nuclear submarines use the shaftless pump technology?
- At present, the submarine has been used in the pump jet technology, the most representative is the United States Virginia class submarine and the Russian North Sea God class submarines.. And shaftless pump is a derivative application of superconducting technology, which is more advanced than pump jet technology..If you want to learn more about shaftless pump technology, you can find relevant papers online.
- Q: Metering pumps related matters
- Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
- Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
- The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)
- Q: What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- Each impeller is of the first stage. (two impellers share only one level, and exit is only level one)