• Electrical Magnetic Pump System 1
Electrical Magnetic Pump

Electrical Magnetic Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:

1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,

2.It's apply to Chemical liquid(acid or alkali) transportation.

3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:


1. Model :MP


2.Pump Material:F-GFRPP  A-CPVC  P-CFRPVDF  E-CFRETFE


3.Power:203-45W  204-65W  255-90W  257-150W  258-260W


4.Connection Type of inlet/outlet :S-screw type   H- Straight pipe type


5.Pump spindle:C-CERAMIC  T-TITANIUM(Ti)  S-SIC


6.Rubber Material :E-EPDM  V-VITON


7.Frequency :5-50Hz  6-60Hz

8.Voltage :V11-110V/220V/1ø  V38-220V/380V/3 ø


Q: What is a solution pump?
(4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.
Q: What is the pump, how to classify, mainly used in where?
1. vane pumpThe impeller pump is driven by the impeller to rotate the liquid at high speed and transfer mechanical energy to the transported liquidAccording to the pump impeller and runner structure characteristics can be divided into different:1) centrifugal pump2) axial flow pump3) mixed flow pump4) vortex pumps3. jet pumpA high velocity jet produced by a working fluid is used to eject the fluid, and then the energy of the ejected fluid is increased by momentum exchange
Q: Is the sewage pump the same as the mud pump?
No. the main functions are different:1, pump two main performance parameters is the displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement
Q: Is the centrifugal pump large or small?
When the liquid is lowered at a certain temperature to the vapor pressure at this temperature, the liquid bubbles. The phenomenon of producing bubbles is called cavitation. When the bubbles are flowing to the high pressure, the volume of the bubbles is reduced so that they are destroyed. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse. The local pump is in operation if the over-current part (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began there, produce a lot of steam bubble formation, when the liquid contains a lot of bubbles by forward high pressure impeller Zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst and the liquid particle at high speed to fill a hole in this moment has a very strong effect of water hammer and the impact of high frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be. The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also produce noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q: What are the main performance parameters of hydraulic pumps?
speedOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q: What are the differences between the sewage pump and the clean water pump?
Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Q: What's the submersible pump?What is a submersible pump, and what about it?
Deep well submersible pump is a fountain, drinking water transportation, irrigation, hot springs, high-rise transport facilities, etc., deep well submersible pump excellent performance, so widely used in various fields.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords