• Electric Mechnical Diaphragm Dosing Metering Pump System 1
  • Electric Mechnical Diaphragm Dosing Metering Pump System 2
  • Electric Mechnical Diaphragm Dosing Metering Pump System 3
Electric Mechnical Diaphragm Dosing Metering Pump

Electric Mechnical Diaphragm Dosing Metering Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                       Mechnical Diaphragm Dosing Metering Pump

1.Structure of Mechnical Diaphragm Dosing Metering Pump

Mechnical Diaphragem Dosing Metering Pump offer the high performance with the max capacity flow upto 1200L/H and with outstanding value for pressure up to 12Bar.This series dosing pump is design for durability cost effiectiveness which is welcome to be used in lines such as water treatment,chemical,power,food and beverage,paper etc...

2.Main features of  Mechnical Diaphragm Dosing Metering Pump

Mechincal actuated diagragm design

Power off seal,no leakage,with security delivery device,simple maintance

Easy operation

It can transport high-viscosity mediums, corrosive liquid and dangerous chemical goods.

The flow can be controlled via adjusting the length of stroke or the motor frequency.

Verious pump head material(PVC,PVDF,SS304,SS316 etc..)

3.Mechnical Diaphragm Dosing Metering Pump Images

Electric Mechnical Diaphragm Dosing Metering Pump

4.VSD Drive Mechnical Diaphragm  Dosing Pump Specification

 

Electric Mechnical Diaphragm Dosing Metering Pump

Electric Mechnical Diaphragm Dosing Metering Pump

Electric Mechnical Diaphragm Dosing Metering Pump

Electric Mechnical Diaphragm Dosing Metering Pump

5.FAQ

·What is the delivery time?

within 20days

 

 

Q: What is a gear pump for?
Gear oil pump is through a pair of parameters and the same structure of the involute gear of each other rolling meshing, the tank of low pressure oil to work can do the important parts of high pressure oil. A power unit that converts the mechanical energy of an engine into hydraulic energy. The engine is prone to the following faults during its use.
Q: What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q: What is the name of the day pump and ground pump? Specific introduction
PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
Q: What are the characteristics of a pipe shield pump?
According to the transmission of liquid temperature, pressure, viscosity and particle level have different requirements, the pump can be divided into the following types: first, the basic type (standard type) transport medium temperature does not exceed 120 degrees, the head of not more than 100m, the pump other types are variations on the basic type and improved.
Q: Rules for operation of centrifugal pumps
Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.
Q: Why is the flow of the pump too small will occur cavitation phenomenon?
This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
Q: Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q: What do you mean by the self coupling device on the pump?
Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.
Q: What are the differences between the sewage pump and the clean water pump?
Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q: How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords