• Ductile Iron wafer butterfly valves DN310 System 1
Ductile Iron wafer butterfly valves DN310

Ductile Iron wafer butterfly valves DN310

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 set
Supply Capability:
80000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Size:

DN50-DN1000

End flange:

ANSI B 16.1,EN1092,AS2129

Face to face:

ANSI B 16.10

Top flange:

ISO 5211

Normal pressure:

PN1.0/1.6MPa(150/200PSI)

Body:

CI/DI/WCB/ALB/CF8/CF8M

Disc:

DI/ALB/Rubber lined Disc/1.2501/1.4529/CF8/Hastelloy Alloy/Monel

Stem:

410/416/304/431/17-4PH/316/monel

Seat:

NBR/Hypalon/EPDM/Neoprene/NR/Wear-Resistant EPDM/Viton/Silicon/Heat-Resistant EPDM/White EPDM/EPDM(NSF)/PTFE

Suitable temperature:

-10~120

Medium:

Fresh water, sewage, sea water, air, vapor, food, medicine, oils, alkalis, salt etc. 

 

A butterfly valve consists of body ,stem ,disc , actuator (manual actuator, worm-gear actuator , aerodynamic actuator or electric actuator) , and wafer type butterfly valve can implement the process for turning on turning off and regulating the flow by the circumrotation of stem and disc  that is droved by actuators.
 

1.Simple and compact construction. Small in size and light in weight. Easy transportation, installation and maintenance.
2. Quick 90 degrees on-off operation. Minimized operating torque ,energy saving.
3. Excellent sealing performance with no leakage. Long service life.
4. Wide selection of materials ,applicable for various media..
5. Flow curve tending to straight line. Excellent regulation performance.

 

Q: What does "D341X-16Q" mean?What do D341-16Q letters and numbers mean for butterfly valves?
D - valve type code: Butterfly valve;3 - valve drive mode code: worm gear;4 - valve connection form code: flange;1 - valve structure type code: vertical plate type;X - seat sealing surface or lining material code: rubber;16 - nominal pressure value: PN1.6MPa;Q - body material code: QT400 - 15.
Q: For whatever reason, Mazda has made it next to impossible to change the PCV valve on the 929. I'm going to have to pull off the plenum and the passenger's side valve cover to replace a $2.00 PCV valve. Before I get too involved, I need to know the torque specs for the valve cover. Also, any other tips on this process would be greatly appreciated. Can I reuse the old valve cover gasket if it's still in good shape? Should I use any kind of sealant in addition to the gasket when I put it all back together? Thanks in advance, by looking at this motor, I can tell I'll have my work cut out for me (for a friggin $2.00 PCV valve, it's usually SO simple!). Like I said, any and all help is greatly appreciated.
Mazda 929 Specs
Q: How do i use a valve spring compressor. It looks like a c-clamp, so don't tell me how to use a smaller one, but the bigger one.Thanks
the forked end of it will go over the spring part and the solid will work on the valve ,you can only use this one if the head is off though,the smaller ones work good if the head is still on the car,the c-clamps style though is the best one to use its safer and wont allow the springs to fly off,good luck.
Q: What's the difference between D71X-16 and D71H-16 butterfly valves?
Model D71X model means this, D represents butterfly valve, 7 represents butterfly connection form for clip type connection, 1 represents straight through, and 16 represents pressure 16 kg pressure.X stands for sealing and soft sealing, and the sealing surface is usually nbr.H stands for metal hard sealing, usually 2Cr13 surfacing.D71X-16 butterfly valve featuresIts main features are:1 、 the design is novel, reasonable, unique structure, light weight, fast opening and closing.2 、 small operating torque, easy operation, labor-saving and smart.3. It can be installed and maintained conveniently in any position.4, seals can be replaced, sealing performance is reliable, to achieve two-way sealing, zero leakage.5, sealing materials aging resistance, corrosion resistance, long service life and so on.
Q: The water supply pipe is the gate valve And on the cross dry pipe are the gate valve? To answer the 30
1, this is a good question, it seems that this has not yet made a unified standard requirements, a bit confused2, personal understanding of fire water supply pipe, pipe shall be installed on the valve, because the valve is fully open all closed features of fire control system is usually required is fully open, easy management features are obvious.3, fire water supply system is also useful to butterfly valve, but mainly signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q: oil coming from valve into turbo charger
it's located on pg 61222 of gm shop repair manual
Q: What are the functions and uses of butterfly valves?
Butterfly valve (English: butterfly valve) refers to the closure of parts (valve or butterfly plate) for the disk, around the valve shaft to achieve rotation and closing of a valve, the main cut off on the pipe and throttling role. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
Q: Butterfly valve is generally used in what position?
It can also be used for switch control of low pressure pipeline medium.
Q: Which is better, the round two lobe butterfly valve?
Can be directly installed in the ventilation pipe, connected with the wind pipe, used to control the speed, adjust the indoor air, the double structure diagram can reduce the space length of the blade is unfolded, and also has the characteristics of small airflow resistance, convenient adjustment etc.
Q: i just finished installing a sprinkler line for my lawn and i used anti siphon valves and 4quot; sprinkler heads. it says in the manual that it has to be at least 6quot; from the highest sprinkler. i think i made a mistake. i installed it 7quot; from the highest 'sprinkler line' . will i have a problem with that regarding the operation of the anti siphon valves and the sprinkler system itself?
If the antisyphon valve is not leaking maybe you should focus attention on the main valve ( assuming it is a solenoid valve) to see if it closes completely. Another thing, if the irrigation zone is on an incline then the water in the system will drain to the lowest point. Sometimes it drains slowly causing the impression of a leaky feed valve.