Specifications of Duct Cable
1,for wire or cable sheath
2,quality SGS and ISO9001
3,delievery time 7 days
4,the highest temperature is 70
this product is used for wire or cable sheath.
Delivery of Duct Cable
PROPERTY | UNIT | SPECIFICATION | TEST | |
HR-70 | JR-70 | |||
tensile strength | Mpa | MORE THAN16.3 | ≥16.8 | GB1040 |
Elongation at break | % | 320 | 310 | GB1040 |
Thermal agining 100°C 168h | -- | -- | -- | -- |
tensile strength at aging | Mpa | 15.4 | 16 | GB1040 |
Maximum change rate of Tensile Strength | % | -7.1 | -4.8 | -- |
Elongation ate Break after aging | % | 300 | 290 | GB1040 |
Maximum change rate of Elongation at break | % | -11.8 | -6.5 | -- |
Weight Loss after Thermal aging | g/cm3 | 9.6 | 11.2 | -- |
Thermal deformation | % | 45 | 35 | -- |
Brittle point of Low temperature impact | °C | (-)40pass | (-)40pass | GB5470 |
Thermal stable time at 20°C | min | 100 | 95 | -- |
Volume resistivity at 20°C | Ω.m | 5.6*1010 | 2.2*1013 | GB1410 |
Volume resistivity at working time of 20°C | Ω.m | -- | 3.5*109 | GB1410 |
Dielectronic strength | mv/m | 28 | 27 | GB1408 |
- Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
- No way to save money! Moreover, the signal to you there, almost all attenuation finished.
- Q: What brand of cable is good, what are the top ten brands of wires?
- Mainly to distinguish the ground which is the ground, the color of the ground is generally yellow-green; wire two is the fire line L and zero line N, no ground wire, look at the plug on the LN mark, the corresponding good.
- Q: What machinery is required to make wire and cable?
- Oh, the pipeline is poured before the layout according to the design drawings.
- Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- Not allowed to slot the proposal with PVC gusset which is only 1 cm thick only open protective layer on it! The water pipe is not enough unless you have a thickened wall outside the decoration.
- Q: Wire and cable CCC product consistency is what
- What brand of wire pipe PVC pipe used? Is not in the financial or plastic surgery better ah? Guiqiu we recommend, thank you! What brand of network cable used a good, need double shielded cable, thank you
- Q: IPhone6 This cable or accessories have not been certified how to solve
- Labor costs you can and workers to discuss, and some labor costs are calculated in accordance with square meters, and some are calculated in accordance with the day, the specific or ask the local construction team
- Q: What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
- BV1 * 2.5 is a 2.5 square line. 2 * 2.5 is two 2.5 square lines. 3 * 2.5 is three 2.5 square lines. 4 * 2.5 is the 4 2.5 square line lighting wire power cord with 2 * 2.5. Light wire with 1.5 is enough. Socket (pipe) with three 2.5 square lines, you can also use 3 * 2.5 a. 4 * 2.5 for three-phase motors.
- Q: Why does the bird stand on the wire without anything, but if people touch it,
- Please provide air-conditioned three-leg socket photo, because you said "open inside is 2.5 square line ~ is a separate line ~" is not very understanding.
- Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
- Q: What are the T and T, s of the wire and cable test type?
- You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!
1. Manufacturer Overview
Location | Shanghai, China |
Year Established | 1998 |
Annual Output Value | USD300,752,660.00 |
Main Markets | Southeast Asia;Mid East;Domestic Market |
Company Certifications | ISO9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 160,000 square meters |
No. of Production Lines | Above 20 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
Duct Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 500M Per Day m
- Supply Capability:
- 5000M Per week m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords