DC Input Moudel Positive Common Terminal Type QX42 Model Isolation Method
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 2300 kg/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Qx42 Parameter Description: DC input 64 points, DC24V 4mA, response time 1 / 5
/ 10 / 20 / 70ms, 32 points, 1 common end, common anode, 40 pin connector * 2.
Specification of Mitsubishi PLC moudel qx42:
[input form] DC input module (positive common terminal type)
[input points] 32 points
[isolation method] Optocoupler
[rated input voltage] DC24V (+ 20 / - 15%, ripple coefficient within 5%)
[rated input current] about 4mA
[enter derating value] refer to derating diagram
[on voltage / on current] 19v or higher / 3mA or higher
[off voltage / off current] 11V or less / 1.7ma or less
[input impedance] about 5.6k Ω
[on - > off response time] 1ms / 5ms / l0ms / 20ms / 70ms or less (CPU
parameter setting) initialization set to 10ms
[off - > on response time] 1ms / 5ms / l0ms / 20ms / 70ms or less (CPU
parameter setting) initialization set to 10ms
[dielectric withstand voltage] 560vac MS / 3 cycles (altitude 2000m (6557.38
feet))
[insulation resistance] 10m Ω or higher measured by insulation resistance
tester
[immunity] through 1500vp-p noise voltage, 1 μ Voice simulator with s voice
width and 25 to 60Hz voice frequency
First instantaneous voice iec61000-4-4: 1kV
[protection grade] IP2X
[common terminal arrangement] 32 points / common terminal (common terminals:
1b01, 1b02, 2B01, 2B02)
[I / O points] 64 (set the I / O allocation according to the 32 point input
module.)
[running indicator] on indication (LED)
[external connection] 40 pin connector
[applicable wire diameter] core 0.3mm2 (for a6con1)
[external wiring connector] a6con1, a6con2, a6con3 (optional)
[applicable connector / terminal strip] a6tbxy36, a6tbxy54, a6tbx70
[5VDC internal current consumption] 90a (standard: all points on)
[overall dimension (h * w * d)] 98 * 27.4 * 90mm
[weight] 0.18kg
- Q: I have two orange electrical outlets in my dorm and I want to plug things like my lamp, fan, phone charger, etc. into them. Is that safe?
- If they fit, then yes. I would use a power surge protector just in case.
- Q: i have problem with my home electrical wiring. the negative and ground pin is live with current even when the power is switched off and when switched on all the three pins are live and most of my electrical equipments are not working. please help?
- Wow. It sounds as though you have lost your neutral and have what is called multiwire circuits in your house. Basically what is happening is you have 120 Volts on both the hot and the neutral/ground of your house. If you most of your equipment isn't working, you really have an issue you need to get looked at. Obviously I'm not standing in your house with a volt meter in my hand so I'm taking your word that the neutral and ground have volts, not current, on them. But if what you say is true then this is the most likely scenario. I strongly recommend you get a professional there quickly.
- Q: Ever since I was a little kid I could tell when there is a T.V on in a house when I walk by. I get this feeling inside like I can sense the signal or something with my brain. When I walk closer to the T.V the feeling gets stronger. If there is a T.V left on in my house with no sound or picture playing, I am still able to sense that the T.V was left on, and pinpoint the exact room its in without even going inside. Does this happen to anyone else?
- If this is a yes or no question the answer is no. As a matter of fact I think you may be pulling our leg a little dab. Even if you can tell if the TV is on I`ll bet you can not tell what channel it`s on without looking or listening. Now how`s that grab you smarty pants? PS I`ll bet you can`t even walk on water.
- Q: For example a computer or a TV.
- Only if it is not automatically switching.
- Q: Can someone tell me more about this MOS or others that relate to this field of work. Also, how will a soldier be utilized under this MOS. thank you
- Well you won't be a Soldieryou will be a Marine 1142 is a High Tech JobElectronicsCircuit boards and the like Great Background in Electronics for a Civilian Career Do not waste your Time in the CorpTake every Electronics course you can Go to Night School and stay out of the Bars and Strip Joints I was a Sgt 1141/42 in Vietnam Earned an EE Degreeowned a successful Business now RetiredX2 You will be assigned to a Utilities Platoon (Extremely Few in Numbers) Within an Engineering Battalion Probably the Least numbers of Marines in any Outfit Must Maintain and Repair any and all Electrical Generators and Pumpswithin the Command you are assigned to ie: 7th Engrs was assigned to the 1st MarDiv in Vietnam Maybe assigned to an MEB aboard shipFMF and make Landings and set up your equipment SEMPER FI !!!!
- Q: I just replaced a light fixture in an apartment complex.I discovered that the bonehead that did the install did not run an equiptment ground when he installed the entire circuit that the light is ran off of (dumb a**!!!!!!!!)Does anyone know if it would be up to code if I where to just drive an 8 ft. ground rod and ground the fixture/entire circuit off of the rod?I have looked everywhere.Cannot find anything in code books.If someone knows where this is in NEC, please include the location.Anybody have any input?
- John I don't know where you are located but there are still some locations where a specific equipment ground wire is not required if BX cable is used. The metallic cable is the ground. There are locations that only only partially adopt the national electrical code. Judging from your search of the NEC it does not sound like you are simply looking for a place to put the ground wire on your lamp. And how old is it? Does it predate the adoption of the NEC in your area? Now if you are saying that you are looking at a non metallic box and you do not have a ground that is another story. Again if you are saying that you tested the circuit and found that a metallic box is not grounded that also might be a different story. Driving a ground rod for a light seems rather extreme. It seems as if there is a bit of information here that is missing. You have some sites below that might help. Do be careful as someone once told me that a little knowledge is a dangerous thing.
- Q: I have a hanging, pull-string electrical light in my attic. This is very standard stuff. I would like to purchase an electrical device that will screw into the electric light and give me an electrical outlet. Think of this as a device with the base of an electric light bulb and an electical outlet instead of the bulb. I thought I saw one in a hardware store 20 years ago, but I have no idea if this product still exists. I can not think of what it would be called with a technical name when searching for one on the Internet.My business application is to be able to plug equipment into my attic rather than running the cord into the main house.
- Electrical circuits in domestic homes normally have two types of circuits. One for the lighting and another for the power supply. You are not supposed to use the lighting circuit for power supply. If you do you may be in contradiction of local wiring rules. As a result if there are any unfortunate events occurring as a consequence you will probably not be covered by insurance. In other words, if you burn your house down from using the lighting circuit for power supply you have no comeback. Having said all this it is unlikely to happen. Lighting circuits have a lower amperage rating and smaller wiring cross section. So therefore they cannot handle too much load, you may find annoying fuse blows or circuit breaker trips. In conclusion, and as an electrician, I recommend you just have a power supply correctly installed. It isn't as expensive as most people think.
- Q: 2)Please do include the details as to why does spark devlop wn connection at one end is loose. 3)How the +ve electrode retains itz polarity though it accepts the electrons continuously, in a closed circuit.
- 1) For laymen understanding, electrical grounding is a protection of your house against lightning, instead burning your house or someone inside your house gets fried. In your appliances, electrical grounding protects you from getting electrical shock in case one of the electrical wire touches the metal body of your appliance. Now on electronic grounding, it is a protection of a certain circuitry from getting damaged by an electrical charge from your body in case you touch it. 2) Electrical wire connection is like a water pipe connection. Electrical current passes through the wire while water current passes through the pipes. If there is a loose connection of a certain electrical wire, or loose pipe connections on your water pipes; The loose pipe connections will produce leaks while the loose electrical connections will produce sparks. 3) It always retain its polarity always. Just like magnets, it retains its polarity, north and south. Electricity is based on magnetism. Law of nature.
- Q: I would like to know about background historical trends in heavy electrical equipment industry in India and future prospects of sourcing heavy electrical equipments in India.If you have any report or thesis on similar topic, please share with me.It would be of immense help to me.
- Suggest that you contact the Indian embassy, trade department, they will probably give you a list of suppliers.
- Q: Can I use 240 volt electrical equipments into 220 volt? Should I need a transformer?
- no you shouldn't need a transformer. Funny I had a guy just the other day that bought a tanning bed and it stated it needed 240vac.he wanted me to hook up a outlet in his garage and I wasn't sure because of the specs. I called the manufacturer and they assured me that I could use 220vac from the house. Not sure why they state it this waybut I assume its the same as when they say 100v and 120v just semantics
Send your message to us
DC Input Moudel Positive Common Terminal Type QX42 Model Isolation Method
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 2300 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches