• Concrete Pumps Spare Parts Rubber End Hose DN125 System 1
  • Concrete Pumps Spare Parts Rubber End Hose DN125 System 2
  • Concrete Pumps Spare Parts Rubber End Hose DN125 System 3
Concrete Pumps Spare Parts Rubber End Hose DN125

Concrete Pumps Spare Parts Rubber End Hose DN125

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

The Concrete Pumps Spare Parts  Rubber End Hose DN125  normally made by special rubber materials,  NR rubber and other rubbers to make sure the quanlity of seals according to customer’s requests, and also package in plywood box or cartons and put into container.

Scope of Application of the Goods

The  Concrete Pumps Spare Parts  Rubber End Hose DN125  is a concrete pumps parts  for combined use with other concrete parts in for concrete pumps and truck pumps. It can be widely used in the construction of various types of concrete structures like industrial and civil buildings, bridges, roads, and other types of infrastructure.

This seals can only be used in Schwing type concrete pumps and truck pumps as well, but not in any other operations.

Product Advantages:

OKorder's  Concrete Pumps Spare Parts  Rubber End Hose DN125 Channels are durable, strong, and safety.

Main Product Features:

·    Premium quality

·    Prompt delivery & seaworthy packing (5-10 days)

Reliable performance

Easy to weld

High safety.

·    Professional Service

·    Competitive pricing

   Measuring of wall thickness from the outside

   Low purchase cost

Specifications:

DN:125MM

Lengh:3M/4M/5M/6M

Remark:Two side Coupling/ One side Coupling/Without Coupling


FAQ:

Q1: How long about delivery time  Concrete Pumps Spare Parts  Rubber End Hose DN125 ?

A1: Normally we keep the raw materials for old customers and sometime we also keep stock products to make sure delivery time in any emergency cases.

Q2: How do we guarantee the quality of our  Concrete Pumps Spare Parts Rubber End Hose DN125?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will book the vessel for goods. The specific shipping date is dependent upon international and government factors, but is typically 7 to 30 workdays.

Q4: If we can produce some goods according to customers request?

A4: Yes, we can produce  Rubber End Hose DN125 according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design for porduction of seals.

Q5: How to make a quick resolution for after service?

A5: OKorder and our manufacture both have overseas branches all-around of world.


Concrete Pumps Spare Parts Rubber End Hose DN125

Concrete Pumps Spare Parts Rubber End Hose DN125

Q: What is the function of a concrete pump hopper grate lever?
The function of a concrete pump hopper grate lever is to control the opening and closing of the hopper grate on a concrete pump. The hopper grate is a metal grid that covers the hopper, which is the chamber where the concrete is loaded before being pumped. The lever allows the operator to easily manipulate the position of the grate, either opening it to allow concrete to flow into the hopper or closing it to prevent any debris or foreign objects from entering the pump system. This control is crucial for ensuring the smooth and efficient operation of the concrete pump, as any obstructions or contaminants in the hopper can potentially damage the pump or affect the quality of the pumped concrete. By using the hopper grate lever, the operator can maintain a steady flow of concrete into the pump and ensure that only clean and properly mixed concrete is being used. Additionally, the lever provides a safety measure, as it allows the operator to quickly close the grate in case of any emergencies or malfunctions. Overall, the concrete pump hopper grate lever plays a vital role in the proper functioning and maintenance of a concrete pump system.
Q: What are the signs of a malfunctioning hydraulic oil cooler?
There are various indications that may suggest a malfunctioning hydraulic oil cooler. 1. Overheating: The engine or hydraulic system experiencing overheating is one of the most common indications. If the hydraulic oil cooler is not functioning correctly, it may fail to adequately cool down the hydraulic fluid, resulting in elevated temperatures in the system. This can result in decreased performance, increased component wear and tear, and potential fluid breakdown. 2. Fluid Leaks: Another indication is the presence of hydraulic fluid leaks. Damaged or worn seals, gaskets, or hoses in a malfunctioning hydraulic oil cooler can cause these leaks. The leaks can be observable as fluid drips or puddles beneath the machinery or as oily residue on components. 3. Increased Noise: A malfunctioning hydraulic oil cooler can also cause heightened noise levels in the hydraulic system. This could be attributed to the introduction of air into the system, leading to cavitation or aeration. These abnormal noises can signal that the cooler is not functioning correctly and should be inspected or replaced. 4. Elevated Temperatures: Consistently higher-than-normal readings on the temperature gauge of your hydraulic system could indicate a malfunctioning oil cooler. The cooler may be unable to effectively dissipate heat from the hydraulic fluid, resulting in rising temperatures. This can lead to reduced efficiency, increased component wear, and potential system failures. 5. Reduced Performance: A malfunctioning hydraulic oil cooler can also result in reduced overall machinery or equipment performance. This can manifest as slower operation, decreased power output, or diminished hydraulic system response. If you observe a decrease in performance, it is advisable to inspect the oil cooler for any issues. Promptly addressing any of these indications is crucial. Continuing to operate machinery with a malfunctioning hydraulic oil cooler can cause further damage, increased downtime, and potentially expensive repairs. It is recommended to consult with a qualified technician or hydraulic specialist to diagnose and resolve any problems with the oil cooler.
Q: Are there any specific guidelines for the installation of wear plates or wear rings in concrete pump spare parts?
Yes, there are specific guidelines for the installation of wear plates or wear rings in concrete pump spare parts. These guidelines typically include ensuring proper alignment and fit, using the correct torque specifications for fasteners, and applying appropriate lubrication. It is important to follow these guidelines to ensure optimal performance and longevity of the wear parts.
Q: Are there any specific guidelines for the disposal of packaging materials of concrete pump spare parts?
Packaging materials of concrete pump spare parts have specific guidelines for disposal. It is advised to adhere to local waste management regulations and authorities' guidelines. To begin with, it is essential to separate the various packaging materials, such as cardboard boxes, plastic wraps, foam inserts, and other materials used for packaging the spare parts. This will facilitate efficient recycling or appropriate disposal of each material. Cardboard boxes can usually be recycled by flattening them and placing them in designated recycling bins. Plastic wraps should also be separated and discarded in specific plastic recycling bins. Foam inserts, commonly used for spare parts protection, may not be recyclable in all areas, so specific recycling instructions should be checked. If recycling is not possible, foam inserts can be disposed of in regular waste bins. Before disposal, it is important to ensure that all packaging materials are free from any residual concrete or other hazardous substances. Any contamination should be cleaned or removed properly to prevent environmental pollution. If the packaging materials cannot be recycled or disposed of through regular waste management methods, it is recommended to contact local recycling centers or waste management facilities to inquire about specific disposal options. They may offer guidance or accept these materials for specialized processing or disposal. Overall, responsible waste management practices should be prioritized, and compliance with local authorities' specific guidelines is crucial to ensure proper disposal of packaging materials for concrete pump spare parts.
Q: What are the different types of concrete pump hopper agitator blades?
The different types of concrete pump hopper agitator blades include spiral blades, flat blades, and paddle blades.
Q: What are the functions of concrete pump truck?
Concrete large transport equipment, used in high-rise buildings, high-speed, overpass and other large concrete works of concrete transmission.
Q: How often should hopper agitator shaft bearings be inspected or replaced in a concrete pump?
The hopper agitator shaft bearings in a concrete pump should be inspected regularly, at least once every six months, to ensure proper functioning. However, the exact frequency of replacement would depend on the manufacturer's recommendations, the intensity of usage, and the condition of the bearings. It is crucial to monitor the bearings for any signs of wear, damage, or excessive vibration, as this can lead to equipment failure and potential safety hazards.
Q: What are the common challenges in sourcing spare parts for stationary concrete pumps?
The common challenges in sourcing spare parts for stationary concrete pumps include limited availability, long lead times, high costs, and compatibility issues with older models. Additionally, the need for genuine parts from reputable manufacturers is crucial to ensure optimal performance and avoid potential breakdowns or safety risks.
Q: What are the signs of a damaged concrete pump agitator motor?
Signs of a damaged concrete pump agitator motor may include unusual noises or vibrations during operation, decreased agitating speed or power, overheating, frequent motor tripping or shutting down, and visible signs of physical damage like cracks, leaks, or broken components.
Q: What are the indications of an inaccurate concrete pump pressure gauge?
There are multiple signs that may suggest an unreliable concrete pump pressure gauge. Below are a few examples: 1. Inconsistent measurements: If the pressure gauge consistently provides varying readings despite consistent concrete pumping conditions, it could indicate an inaccurate gauge. For instance, if the gauge shows a pressure of 1000 psi one moment and then suddenly jumps to 1500 psi without any significant changes in the pumping operation, it could suggest a problem with the gauge. 2. Abnormal readings: If the pressure gauge consistently displays excessively high or low pressure readings that deviate significantly from the expected values, it may imply an inaccurate gauge. It is crucial to be aware of the usual pressure range for the specific concrete pumping operation to identify abnormal readings. 3. Incompatibility with other gauges: If there are multiple pressure gauges installed in the concrete pumping system and they provide notably different readings, it may indicate that one or more of the gauges are inaccurate. By comparing the readings from various gauges, it is possible to determine if a particular gauge is faulty. 4. Insufficient pump performance: If the concrete pump is not performing as anticipated, such as experiencing reduced output or inconsistent flow rates, it may be a result of inaccurate pressure readings. Inaccurate pressure measurements can disrupt the control of the pump's hydraulic system, leading to inefficiencies in pumping operations. 5. Physical damage or wear: Any visible damage or signs of wear on the pressure gauge, such as cracked glass, bent needles, or loose connections, can compromise its accuracy. Such physical damage can result in inaccurate readings and should be promptly addressed. Regular calibration and maintenance of the pressure gauge are essential to ensure accurate readings. If any indications of an inaccurate gauge are observed, it is advisable to consult a professional technician or engineer to assess the situation and take appropriate actions to rectify the issue.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords