• Cable Tie with High Quality and Releasable Price System 1
Cable Tie with High Quality and Releasable Price

Cable Tie with High Quality and Releasable Price

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1000 Pieces m
Supply Capability:
100000 Bags per Week m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

 

Material;Nylon  66,  94V-2  certificated  by  UL.Heat-resisting,Acid & erosion control, insulate well and not apt to age.

 

Operating temperature;-35 Degree to 85 Degree.

 

Color;Natural(or white, standard color),UV black and other colors are available as  requested.

 

 

Size as Following:

 

ITEM.NO.

L

W(mm)

MAX.BUNDLE DIA.(mm)

TENSILE STRENGTH

INCH

MM

LBS

KGS

S-200RT

8″

200

7.5

45

50

20

S-250RT

10″

250

7.5

45

50

20

S-300RT

12″

300

7.5

45

50

20

S-350RT-2

135/8″

350

8

45

50

22

S-400RT-2

15 3/4"

400

8

105

50

22

S-450RT-2

17 3/4″

450

8

130

50

22

S-500RT-2

1911/16″

500

9

150

65

30

S-550RT-2

2111/16″

550

9

160

65

30

S-100RT-3

4″

100

2.5

22

18

8

S-145RT-3

6″

150

2.5

35

18

8

S-150RT-3

6″

150

3.5

35

40

18

S-300RT-4

11 5/8″

300

12.7

82

250

114

S-400RT-4

15 3/4"

400

12.7

105

250

114

S-450RT-4

17 3/4"

450

9

118

175

80

S-550RT-4

21 3/4″

550

9

160

175

80

S-780RT-4

3011/16″

780

12.7

230

250

114

 

Q: The role of cable connector box classification installation requirements
Although electricity and power generation are all power lines, they can be seen as two different systems. Therefore, when laying the cable, if the laying of the cable from the same bridge, the partition will be separated from the cable for future maintenance and maintenance. The The requirements of the partition depends on the depth of your bridge, the partition placed in the bridge, the bridge as high or slightly lower, if higher than the frame of the frame, affecting the beautiful, detailed provisions There is no ready-made plaintext.
Q: Computer behind the wire is messy, what way to change the neat little Such as
Plus a separate graphics card. Must be dual interface that kind of discrete graphics. In this way, the computer watching movies, television can also see. But installed, you need to set up. Or is the connection to support Cao Cao Yu 丨 good check pupil intestinal traps. Because now a lot of digital TV can plug the cable to watch the movie. this is okay too
Q: I got the machine, and then removed, there is a section of the tube was bent, and that position really need to fold before, because there is a turn, but now that place too hard, and completely unreasonable that he is normal Of the time, because the demolition of a little time will be folded, do not know that they may be deliberately? And then to add money, encounter this situation usually how to do more
Single-core cable line grounding line commonly used grounding 1. shield one end directly grounded, the other end through the protective layer to protect the ground: When the line length of 500 --- 700m and below, the shield can be used directly to one end of the ground (cable terminal Position ground), the other end through the protective cover to ground. 2. shield the midpoint of the ground: When the line length of 1000 ---- 1400m, the use of midpoint grounding. in the middle of the line position, the shield directly grounded, the cable ends of the shield through the protective cover to ground. The middle ground is usually required to install a straight connector. Install an insulated connector at the midpoint of the line. The insulated connector disconnects the cable shield, and the shield is grounded through the protective cover, and the two cables are shielded and grounded directly. 3. Shielded cross-connect cable lines are very long (1000 --- 1400m above), you can use shield cross-connect. This method is divided into three equal parts of the length of the three or three times the number of segments, each section between the installation of insulation joints, insulation joints between the three-phase shield with a coaxial cable, cross-linked box for transposition, cross The interconnection box is provided with a set of protective protector, and the two sets of insulated connectors are arranged on the line.
Q: Ordinary air conditioning louvers, one square meter of louver aluminum consumption is good?
Tray cable tray, it has a light weight, load, handsome in appearance, simple structure, easy installation, it is suitable for power cable installation, but also for the control cable laying Cascade cable bridge, suitable for general straight light cable laying, especially for high and low power cable laying
Q: The elevator has 23 floors. But I have not installed before. I would like to ask how to install. How does the video line go? Thank you more
Must be looking for maintenance elevators are under the staff communication, because we are not on the elevator car roof are right. Let them cooperate. And then to the top of the elevator to make a hole on it. Elevator top 220 power supply! It is best not to take, the elevator power failure will be invalid, how to see someone in the elevator did not. Signal line extension of this cable with cable tie, must be shielded, there are lifts are dedicated. Ordinary signal lines can also be used with soft!
Q: Five ridge hoarding locusts on the high-chu chu chu chu floor layer. Two elevators tied side by side, to cloth video cable, how cloth ah? The The Online to say with the network cable, there is a direct use of coaxial video! I would like to ask how to use coaxial video cable cloth? The Will there be a reserved interface on the car? Or need to take electric drill to play the outer hole, the video line into the box to go inside? The High phone, detailed words ah! The The Thank you! The More
With real estate license, household ID card, you can come to the cable TV business hall to go directly
Q: What are the maintenance knowledge of the manipulator?
1: rails and bearings to keep all the shafts at the guide and bearing cleaning and good lubrication performance
Q: What are the precautions for using the cable mesh and how to use it?
No instructions are clearly stated or allowed. In the "Code for Design of Electric Power Cables" (GB-2007), the provisions of 5.1.3 stipulate that if the number of cables in the same channel is large, if the laying of the multi-layer bracket on the same side, the following provisions shall be met: High to low power cables, strong to weak control and signal cables, communication cables "top to bottom" in the order. When the horizontal channel contains more than 35kV high-voltage cable, or to meet the introduction of the cabinet tray to meet the requirements of the bend radius requirements, should be "bottom-up" in order. In the same project or the cable channel extends to different projects, should be arranged in the same order. 2 bracket space by the channel space constraints, 35kV and below the adjacent voltage level power cables can be arranged in the same layer of support, 1kV and below the power cable can also be with the strong control and signal cable configuration in the same layer of the bracket. 3 The work of the same important circuit and the backup cable should be arranged on the different layers of the brackets. It is possible to note that it is restricted by passage space from section 2. If you really want to lay together, it should be noted that 10kV cable can not use single-core cable, you need to use three-core cable.
Q: Whether the wire entry and exit distribution box should be reserved length
If the cable, the current should be appropriate to reduce, take 6-7A more appropriate. Total power 1300-1500W.
Q: Will the power cord wiring with what is called, how the insulation effect
One is four 50 flat one is a 4 * 50
Our company is incorporated with manufacture, sales and especially produce electrical accesories items ,terminals,cable ties;cable galnds,heat shrinkable tubes, and general purpose relay, power relay, latching relay, automotive relays, time relays, counters,temperature controller,relay sockets ,switches, contactors, fuses, MCB, starters etc which are widely used in the fields of house-hold appliance, auto-control, voltage-stablizing, electric component, communication and office equipment.

1. Manufacturer Overview

Location Zhejiang, China
Year Established 2009
Annual Output Value Below US$1 Million
Main Markets North America
South America
Eastern Europe
Oceania
Mid East
Eastern Asia
Western Europe
Company Certifications ISO 9001:2000

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port ningbo,shanghai
Export Percentage 81% - 90%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 3,000-5,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered Buyer Label Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches