• SQUEEZE CONNECTOR-ZINC Right Angle 90 Degrees System 1
  • SQUEEZE CONNECTOR-ZINC Right Angle 90 Degrees System 2
  • SQUEEZE CONNECTOR-ZINC Right Angle 90 Degrees System 3
SQUEEZE CONNECTOR-ZINC Right Angle 90 Degrees

SQUEEZE CONNECTOR-ZINC Right Angle 90 Degrees

Ref Price:
$0.16 - 6.10 / pc get latest price
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
1000 pc
Supply Capability:
300000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Material:

Zinc Die-cast
Size: 3/8”—2”
Field Names:
Snap-in connector, snap-lock connector, quick-snap connector, flex connector, flex metal conduit connector, snap in BX connector, snap in MC cable connector. squeeze angle connector
Applications:
These quick connectors are used to connect flexible metal conduits to boxes, enclosures, lighting fixtures and other appliances. Available in a variety of styles, straight and 90°, they can be screwed into flexible
metal conduits or clamped on the outside of jackets.

 

 

 

 

Q: 1000 kW 600 m cable to use much
Such a large load so far away, can only be transported with 10KY, near the installation of the transformer Caixing, if the 380V transmission, cross-sectional area, high cost, loss of large, not worthwhile. 10KV high-pressure delivery, current 55A, with 25mm? copper cable 35mm? aluminum cable delivery on it. If the 380V transmission, according to the line voltage loss simple calculation formula △ U% = PL / CS take △ U% = 5 copper cable S = PL / CS △ U% = 1000X600 / 77X5 = / 385 = 1558mm? aluminum cable S = PL / CS = U06 / 46X5 = / 230 = 2307mm? Line voltage loss △ U Simple calculation formula △ U% = PL / CS △ U% - Percentage of voltage loss P - Active power of conveying (Kw) Distance of L- M) C-constant, aluminum single-phase 8.. aluminum three-phase four-wire 46; copper single-phase 12.. copper three-phase four-wire 77S-conductor cross section (mm?) (quoted from "electrical entrance permit test low pressure Class theory "" electrical engineering basis ")
Q: Is the cable head made of every building?
Building in accordance with the floor or unit configuration distribution box, there are office buildings using a total box. Where there is a cable out of the situation, must be wrapped to make the cable head, according to the choice of distribution box circuit breaker wiring crimp or not crimp the cable terminal. In other words, the cable head must be made, but not necessarily crimp the cable terminal.
Q: What is the meaning of PG + digital markings for electrical wiring?
If no color distinction, 100 meters after you know which line of the fire line which line? The
Q: How much of the cable with the switch?
The switch is selected according to the current. General switch = (2-2.5) Current three-phase current = P / 1.732 / 0.38 / 0.8 Single-phase current = P / 0.22 / 0.8
Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
heat shrinkable casing (MRSG) is a new environmentally friendly halogen-free flame retardant casing, inexpensive products, for wire, cable and wire terminals to provide insulation protection
Q: Can the main cable be aluminum cable? And explain why, thank you!
Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
Q: 5 air conditioning can be used 4 square cable
Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
Q: The difference between nylon balls and geese and ducks
As long as the cable is thick enough, 20 meters of the basic loss can be ignored.
Q: 6 square cable up to how many air conditioning (1.5P)
If it is connected to the 220V of the electricity above the 6 square of the copper line can be
Q: 25 square copper cable how much money one meter?
There is no 1..2..4.5 square wire. The family uses most of the four wires with 1.. 1.. 2.5 and 4. Power 1KW Approx. 5A.3KW Approx. 15A.2.5 square copper wire can be used. Plug or empty open (25A).

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords