• Butterfly Valve Without Pin Ductile Iron DN300 System 1
Butterfly Valve Without Pin Ductile Iron DN300

Butterfly Valve Without Pin Ductile Iron DN300

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 set
Supply Capability:
50000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Centerline structure,pinless double half shaft design.
Disc has two-way bearing, no installation direction requirements.
Non-backed replaceable seat with good performance and a longer working life.
Square and short neck for lable use and cost saving.
Easy installation, no need flange gasket.

 

SizeDN50mm-DN600mm
Design standardAPI609/EN593
End flangeDINPN10/PN16, BS4504PN10/PN16, ANSI class125#/class150#
Face to faceAPI609/EN558-1
Top flangeISO5211
BodyDuctile iron/Cast iron
DiscDuctile iron/CF8/CF8M/C95400/C95500
StemSS420
SeatEPDM/NBR/Viton/PTFE
ActuatorBare shaft/Lever/Gearbox and handwheel
CoatingEpoxy/Nylon/PTFE
PinWith out pin
Suitable mediumWater/Seawater/Sewage/Air/Foodstuff/Oil

 

 

Q: Does the wet alarm valve group need to install the signal butterfly valve?
Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q: When will Butterfly Valves be used?
Butterfly valve has the advantages of simple structure, easy operation, small footprint and light weight;1, for the city water supply network in general, DN300 still DN300 valve, butterfly valve above, this installation is convenient (especially large diameter valve installation is inconvenient, the weight of large volume, big);2, there are sediment pipeline, such as powder, mud and other mixed substances;
Q: In the pipeline attached building Atlas 05S502, in the middle of a water meter and check valve, the two sides are divided into two butterfly valve, want to ask why to arrange this way, what is the role of the two butterfly valve?
Check the water gauge and check valve on both sides to facilitate the maintenance and replacement of water meter and check valve.
Q: I have 1993 Seville 4.9. I got a new EGR valve but it didn't help. I tested it with vacuum pump, it won't hold pressure at all, same with old one. Is that new EGR valve bad or just different type of EGR that vacuum pump won't work? Thanks!
HI i have question is all EGR valve work the same ? I Have an 86 Rx7 and when I test the EGR valve is doesn t hold pressure. So I m curios are they different from other vehicle due to is a rotary engine or due they all work the same. Thank You.
Q: The difference between gate valve and butterfly valve, as well as cut-off valve, what are their applicable conditions? Advantages and disadvantages?
The gate valve is one of the simplest valves. Generally manual, most of the electric valve failure, as a manual. Butterfly valve is more, I saw the pneumatic butterfly valve, that is, with gas control closed, general and solenoid valve matching.
Q: How to calculate the size of the manual butterfly valve?
I don't know what size you mean, and what about DN in diameter, such as DN125, which means 125 cm in diameter
Q: How do hydraulic butterfly valves work?
Butterfly valve hydraulic drive device working principle1. manual operationWhen the hydraulic system suddenly fails, the valve can not move when the butterfly plate at any stop. Then, shaking the manual device, the guide block guide block in front of the manual shaft together with the driving shaft end, the cogging and drive shaft spline manual corresponding to the slot. Then, by dialing the driving device, the dial is shifted to the left end, and the transmission spline is connected with the manual shaft by a gear sleeve (the driving device is provided with a limit for preventing the tooth sleeve from jumping up), and the crank is disengaged from the hydraulic cylinder to disengage the hydraulic cylinder. Then turn the manual device and use the manual device to realize the disc movement.2. hydraulic operationWhen the hydraulic system returns to normal operation, the actuating device needs to be operated by hand. First, adjust the hydraulic cylinder to its initial state (0 digits) or at any position. Then manually adjust the opening of the disc to the position corresponding to the cylinder stroke (by observing whether the mark on the gear sleeve is in accordance with the mark on the crank, and judge the position of the disc and the cylinder). Then pull the gear sleeve and engage the spline on the crank by poking the driving device. Then fix the shift to prevent jumping. At this point, start the hydraulic system to restore fluid flow.
Q: Butterfly valves are widely used in 2.0MPa below the pressure and temperature of not more than 200 degrees of various media, right?
First of all, is not the butterfly valve butterfly valve.Butterfly valve in the valve around the fixed axis rotating valve, called butterfly valve.1., as a sealed butterfly valve, it has been developed rapidly since the appearance of synthetic rubber, so it is a new type of shut-off valve. In our country until 1980s, the main role of butterfly valves in low-pressure valves, valve seat using synthetic rubber, by 90s, hard seal "metal seal" butterfly valve to rapid development. There are a number of valve factory can produce steady pressure metal seal butterfly valve, butterfly valve shall be shipped to a broader area.2. butterfly valves can transport and control the medium with water, condensed water, recycled water, sewage, sea water, air, gas, liquid gas, dry powder, mud, fruit pulp and a mixture of suspended solids.The domestic butterfly valve parameters are as follows:Nominal pressure: PN0.25 - 4.0MPaNominal diameter: DN100 - 3000mmWorking temperature: less than or equal to 425 DEG C
Q: The difference between vertical and horizontal butterfly valves in municipal water supply
Vertical and horizontal only installation directions and installation methods are different. Functionally, there is no difference.The main difference between the two methods of installation is that:1. horizontal can effectively avoid the high temperature radiation above the pipe. The disadvantage is that it takes up a lot of space.The advantage of the 2. vertical is that the occupation space is smaller, and it is easy to install. If the pipeline is higher, it is not convenient for maintenance.
Q: What's the meaning of butterfly valve d371po?
According to the provisions of the JB/T 308-2004 valve type programming method:D== butterfly valve3== transmission: worm gear7== connection mode: clip type1== structure: midlinePo== sealing surface material: lining PoPo== propylene oxide (PO)

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords